ABB 1SBL931074R8101 Block Contactor - 690V, 3-Pole, UL/CE

Part Number: 1SBL931074R8101
Manufacturer
ABB
Part number
1SBL931074R8101

Quick Summary

Block Contactor ABB 1SBL931074R8101 is designed to control three-phase motors and power circuits up to 690 V AC in demanding industrial environments. The design helps reduce downtime through reliable AC-operated control, a built-in auxiliary contact, and modular add-on options for front or side mounting that simplify wiring. Certifications include CE conformity, UL/CSA listing, and CCC/CQC declarations, with RoHS compliance and an IP20 rating for coil and terminals. The compact 44 mm width, 74 mm depth, and 76.3 mm height enable space-efficient panel layouts while delivering 24 V control and robust performance at 50/60 Hz. For system integrators and operators, this supports scalable automation, predictable maintenance, and lower lifecycle costs.

Product Information

Extended Description

1SBL931074R8101 ABB: AX09...AX25 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100187L0203
Instructions and Manuals
AX 06~40A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
44 mm
Product Net Depth / Length
74 mm
Product Net Height
76.3 mm
Product Net Weight
0.326 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
1
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 32 A | acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 55 °C 27 A | (690 V) 40 °C 32 A | (690 V) 70 °C 23 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 25 A | (440 V) 55 °C 16 A | (500 V) 55 °C 14 A | (690 V) 55 °C 10 A | (380 / 400 V) 55 °C 25 A | (220 / 230 / 240 V) 55 °C 25 A
Rated Operational Current AC-15 (Ie)
(500 V) NC 2 | (500 V) 2 A | (690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (380 / 400 V) 3 A | (400 / 440 V) 2 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (110 V) 1.1 A / 121 W | (125 V) 1.1 A / 138 W | (220 V) 0.55 A / 121 W | (250 V) 0.55 A / 138 W | (400 V) 2.8 A / 134 W | (500 V) 2 A / 144 W
Rated Operational Power AC-3 (Pe)
(415 V) 11 kW | (440 V) 9 kW | (500 V) 9 kW | (690 V) 9 kW | (380 / 400 V) 11 kW | (220 / 230 / 240 V) 6.5 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 200 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 32 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 85 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 105 A | for 0.1 s 140 A | for 1 s 100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-15) 1200 cycles per hour | (AC-3) 1200 cycles per hour | (DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 24 V | 60 Hz 24 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 1.2 W | at Rated Operating Conditions AC-3 per Pole 0.35 W
Operate Time
Between Coil De-energization and NC Contact Closing 9 ... 16 ms | Between Coil De-energization and NO Contact Opening 4 ... 11 ms | Between Coil Energization and NC Contact Opening 7 ... 21 ms | Between Coil Energization and NO Contact Closing 10 ... 26 ms
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Auxiliary Circuit 1 N·m | Control Circuit 1 N·m | Main Circuit 1.2 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
General Use Rating UL/CSA
(600 V AC) 30 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 2 hp | (200 ... 208 V AC) Three Phase 7.5 hp | (220 ... 240 V AC) Three Phase 7.5 hp | (240 V AC) Single Phase 3 hp | (440 ... 480 V AC) Three Phase 15 hp | (550 ... 600 V AC) Three Phase 15 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 11 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 24 A | (200 ... 208 V AC) Three Phase 25.3 A | (220 ... 240 V AC) Three Phase 22 A | (240 V AC) Single Phase 17 A | (440 ... 480 V AC) Three Phase 21 A | (550 ... 600 V AC) Three Phase 17 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CB Certificate
AX 06~25A CB certification
CCC Certificate
9AKK107492A7089
CCS Certificate
CCS Certificate of AFC09 ... AFC96 , AX09-AX370 contactors
CQC Certificate
CQC Certificate, Contactor, AX06, AX09, AX12, AX18, AX25, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX06, AX09, AX12, AX18, AX25, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AX06, AX09, AX12, AX18, AX25, AX32, AX40, AX50, AX65, AX80 3-pole Contactors
UL Certificate
UL Certificate of Compliance – AX06, AX09, AX12, AX18, AX25
Package Level 1 Units
box 1 piece
Package Level 1 Width
48 mm
Package Level 1 Depth / Length
78 mm
Package Level 1 Height
79 mm
Package Level 1 Gross Weight
0.34 kg
Package Level 1 EAN
3471522398819
Package Level 2 Units
30 piece
Package Level 2 Width
240 mm
Package Level 2 Depth / Length
295 mm
Package Level 2 Height
145 mm
Package Level 2 Gross Weight
10.2 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
E-Number (Finland)
3707331
Feature → Business Impact → Application: The AX25-30-01-81 design uses three main NO contacts and one built-in NC auxiliary contact, allowing reliable three-phase motor control with interlock capabilities, reducing wiring complexity and panel space while improving fault isolation in conveyors and pumps. Feature → Business Impact → Application: Control circuit voltage of 24 V AC keeps compatibility with standard automation relays and PLCs, enabling quick integration into existing control architectures and lowering installation time across machine tools and packaging lines. Feature → Business Impact → Application: Rated operational currents at 690 V across AC-1 and AC-3 paths (e.g., 27–32 A AC-1, 10–16 A AC-3 at higher voltages) ensure robust motor starting and soft-start options for fans and pumps without overdesign. Feature → Business Impact → Application: Low power loss per pole (1.2 W AC-1; 0.35 W AC-3) minimizes heat in control panels, reducing cooling costs and enabling denser panel mounting for automation panels. Feature → Business Impact → Application: High mechanical switching frequency (3600 cycles/hour) supports high-demand automation cycles in stamping, extrusions, and material handling, while maintaining reliable operation and predictable maintenance needs. Feature → Business Impact → Application: IP20 protection and screw terminals with tightening torques (Auxiliary 1 N·m, Main 1.2 N·m) provide safe, easy installation in clean, indoor environments and straightforward field wiring with robust mechanical retention. Feature → Business Impact → Application: Compatibility with add-on auxiliary contact blocks and a broad protection and compliance footprint (RoHS, CE, UL/CSA, CCC, CQC) supports scalable installations and regulatory alignment across global facilities.

Get a Quick Quote for a ABB 1SBL931074R8101

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL931074R8101? Enquire Now

FAQs

Install the unit on a clean, indoor panel with IP20-rated terminals. Use screw terminals and tighten per 1 N·m (aux) and 1.2 N·m (main). Ensure 24 V control wiring and 50/60 Hz supply are stable, and maintain adequate clearance for heat dissipation in compact cabinets.
Main contacts are 3 NO poles rated for AC-1 up to 32 A and AC-3 up to 10–16 A depending on voltage, with coil control at 24 V and 50/60 Hz. It is built for up to 690 V, 3-pole motor control with 9–26 ms operate times and corresponding thermal ratings.
Yes, it supports ambient temperatures from -25 °C to 55 °C with an option for close-to-contactor operation that manages thermal load. For storage and transport, it tolerates wider ranges, but in service, staying within 40 °C ambient is typical for rated currents.
The device carries CE conformity and UL/CSA listings, along with CCC/CQC declarations. It also aligns with RoHS requirements and IP20 protection, ensuring compliance across global electrical safety and environmental standards.
The contactor offers low coil power loss (1.2 W per pole AC-1, 0.35 W AC-3), reducing heat and cooling needs. With a high mechanical switching frequency and reliable 24 V control, maintenance intervals are longer and energy costs are lower, delivering favorable total cost of ownership in continuous motor control applications.