ABB 1SBL931074R8301 Block Contactor is a 3-pole AC-operated device designed for 690 V motor circuits. Engineers often struggle with reliable, space-efficient switching under variable loads and tight panel footprints. This unit carries industry-grade certifications including UL/CSA and CE, with IP20 terminations for coil and main terminals, plus CQC and CCC declarations for global deployments. In addition to robust protection, its compact 44 mm width and integrated auxiliary contact block enable scalable control within standard switchgear enclosures, aligning with modern factory automation strategies while reducing wiring complexity and installation time.

Product Information

Extended Description

1SBL931074R8301 ABB: AX09...AX25 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100187L0203
Instructions and Manuals
AX 06~40A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
44 mm
Product Net Depth / Length
74 mm
Product Net Height
76.3 mm
Product Net Weight
0.326 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
1
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 32 A | acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 55 °C 27 A | (690 V) 40 °C 32 A | (690 V) 70 °C 23 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 25 A | (440 V) 55 °C 16 A | (500 V) 55 °C 14 A | (690 V) 55 °C 10 A | (380 / 400 V) 55 °C 25 A | (220 / 230 / 240 V) 55 °C 25 A
Rated Operational Current AC-15 (Ie)
(500 V) NC 2 | (500 V) 2 A | (690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (380 / 400 V) 3 A | (400 / 440 V) 2 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (110 V) 1.1 A / 121 W | (125 V) 1.1 A / 138 W | (220 V) 0.55 A / 121 W | (250 V) 0.55 A / 138 W | (400 V) 2.8 A / 134 W | (500 V) 2 A / 144 W
Rated Operational Power AC-3 (Pe)
(415 V) 11 kW | (440 V) 9 kW | (500 V) 9 kW | (690 V) 9 kW | (380 / 400 V) 11 kW | (220 / 230 / 240 V) 6.5 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 200 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 32 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 85 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 105 A | for 0.1 s 140 A | for 1 s 100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-15) 1200 cycles per hour | (AC-3) 1200 cycles per hour | (DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 48 V | 60 Hz 48 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 1.2 W | at Rated Operating Conditions AC-3 per Pole 0.35 W
Operate Time
Between Coil De-energization and NC Contact Closing 9 ... 16 ms | Between Coil De-energization and NO Contact Opening 4 ... 11 ms | Between Coil Energization and NC Contact Opening 7 ... 21 ms | Between Coil Energization and NO Contact Closing 10 ... 26 ms
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Auxiliary Circuit 1 N·m | Control Circuit 1 N·m | Main Circuit 1.2 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
General Use Rating UL/CSA
(600 V AC) 30 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 2 hp | (200 ... 208 V AC) Three Phase 7.5 hp | (220 ... 240 V AC) Three Phase 7.5 hp | (240 V AC) Single Phase 3 hp | (440 ... 480 V AC) Three Phase 15 hp | (550 ... 600 V AC) Three Phase 15 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 11 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 24 A | (200 ... 208 V AC) Three Phase 25.3 A | (220 ... 240 V AC) Three Phase 22 A | (240 V AC) Single Phase 17 A | (440 ... 480 V AC) Three Phase 21 A | (550 ... 600 V AC) Three Phase 17 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CB Certificate
AX 06~25A CB certification
CCC Certificate
9AKK107492A7089
CCS Certificate
CCS Certificate of AFC09 ... AFC96 , AX09-AX370 contactors
CQC Certificate
CQC Certificate, Contactor, AX06, AX09, AX12, AX18, AX25, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX06, AX09, AX12, AX18, AX25, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AX06, AX09, AX12, AX18, AX25, AX32, AX40, AX50, AX65, AX80 3-pole Contactors
UL Certificate
UL Certificate of Compliance – AX06, AX09, AX12, AX18, AX25
Package Level 1 Units
box 1 piece
Package Level 1 Width
48 mm
Package Level 1 Depth / Length
78 mm
Package Level 1 Height
79 mm
Package Level 1 Gross Weight
0.34 kg
Package Level 1 EAN
3471522398833
Package Level 2 Units
30 piece
Package Level 2 Width
240 mm
Package Level 2 Depth / Length
295 mm
Package Level 2 Height
145 mm
Package Level 2 Gross Weight
10.2 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature → Business Impact → Application: The 3 main normally open contacts plus a single built-in NC auxiliary contact provide flexible motor control in a compact 44 mm wide footprint, reducing panel height without sacrificing switching capacity. Result: streamlined wiring and reduced cabinet depth in small to mid-size machines such as conveyors and pumps, where space is at a premium. Application: control of 3-phase motors up to 690 V in packaging lines or materials handling. Feature → Business Impact → Application: Rated for 690 V insulation with 50/60 Hz control and main circuits, meeting international standards and improving compliance confidence across subsidiaries. Benefit: fewer revision cycles and faster approvals for multi-region installs. Application: heavy-duty fans, pumps, and machine tools. Feature → Business Impact → Application: 48 V control circuit voltage with AC operation enables straightforward integration with standard PLC memories and HMI panels. Benefit: simplified control wiring and reliable energize/de-energize timing. Application: control panels and machine controllers. Feature → Business Impact → Application: Power loss of 1.2 W per pole in AC-1 and 0.35 W per pole in AC-3 reduces heat and energy use in continuous operation. Benefit: cooler panels and lower cooling costs in high-duty environments. Application: long-running conveyors and grinders. Feature → Business Impact → Application: Compact dimensions (44 x 74 x 76.3 mm) and total weight of 0.326 kg enable easy stacking and mounting in tight control cabinets. Benefit: higher packing density and faster installation. Application: compact automation installations and retrofit projects. Feature → Business Impact → Application: IP20 protection, screw terminals, and tightening torques of 1 N·m and 1.2 N·m ensure secure, vibration-tolerant connections. Benefit: durable field wiring and dependable operation in industrial environments. Application: panel-mount and door-mounted control blocks. Feature → Business Impact → Application: Comprehensive accessory ecosystem including add-on auxiliary contact blocks and front/side mounting options. Benefit: scalable control logic and future-proofing for upgrades. Application: retrofits and expansion of existing AX-series installations.

Get a Quick Quote for a ABB 1SBL931074R8301

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL931074R8301? Enquire Now

FAQs

This block contactor uses screw terminals with IP20 protection for main, auxiliary, and coil terminals. Its compact footprint (44 mm width) and standard dimensions (74 mm depth, 76.3 mm height) simplify panel mounting and wiring in compact control cabinets.
AC-1 rated current is up to 32 A at 690 V and 27 A at 220/240 V, depending on ambient temperature. AC-3 ratings include up to 25 A at 415 V and 16 A at 440 V, with variations up to 10 A at 690 V, reflecting suitability for motor starting and short-time duty.
The unit carries UL/CSA general use ratings, CE declarations of conformity, CCC and CQC certificates, and EU CE compliance. These certifications support regulatory compliance across North America and Europe for industrial equipment.
The coil is 48 V with a 50 Hz or 60 Hz control frequency, enabling direct compatibility with common PLC outputs and control relays. This simplifies control wiring and reduces the need for additional interface components.
Rated operation ranges include ambient temperatures from -25 to 55 °C with an optional thermal overload relay, and up to -40 to 70 °C without it. The product is rated for altitudes up to 3000 m without derating and features IP20 protection for robust indoor use.