ABB 1SBL931074R8410 Block Contactor - 690 V CE/UL

Part Number: 1SBL931074R8410
Manufacturer
ABB
Part number
1SBL931074R8410

Quick Summary

ABB 1SBL931074R8410 Block Contactor is a compact three-pole switch designed to control 3-phase motors and power circuits up to 690 V AC. In panel builds where space is at a premium, its 44 mm width and screw-terminal wiring streamline installation and reduce cabinet clutter. It carries CE and UL certifications, with RoHS/REACH declarations and IP20 protection on terminals to enhance safe operation in harsh industrial environments. The 110 V control circuit operates at 50/60 Hz, enabling reliable energization across regional grids. With efficient coil design and strong mains ratings, it delivers durable performance while helping reduce heat, energy consumption, and maintenance costs for demanding applications.

Product Information

Extended Description

1SBL931074R8410 ABB: AX09...AX25 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100187L0203
Instructions and Manuals
AX 06~40A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
44 mm
Product Net Depth / Length
74 mm
Product Net Height
76.3 mm
Product Net Weight
0.326 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
0
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 32 A | acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 55 °C 27 A | (690 V) 40 °C 32 A | (690 V) 70 °C 23 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 25 A | (440 V) 55 °C 16 A | (500 V) 55 °C 14 A | (690 V) 55 °C 10 A | (380 / 400 V) 55 °C 25 A | (220 / 230 / 240 V) 55 °C 25 A
Rated Operational Current AC-15 (Ie)
(500 V) NC 2 | (500 V) 2 A | (690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (380 / 400 V) 3 A | (400 / 440 V) 2 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (110 V) 1.1 A / 121 W | (125 V) 1.1 A / 138 W | (220 V) 0.55 A / 121 W | (250 V) 0.55 A / 138 W | (400 V) 2.8 A / 134 W | (500 V) 2 A / 144 W
Rated Operational Power AC-3 (Pe)
(415 V) 11 kW | (440 V) 9 kW | (500 V) 9 kW | (690 V) 9 kW | (380 / 400 V) 11 kW | (220 / 230 / 240 V) 6.5 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 200 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 32 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 85 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 105 A | for 0.1 s 140 A | for 1 s 100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-15) 1200 cycles per hour | (AC-3) 1200 cycles per hour | (DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 110 V | 60 Hz 110 ... 120 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 1.2 W | at Rated Operating Conditions AC-3 per Pole 0.35 W
Operate Time
Between Coil De-energization and NC Contact Closing 9 ... 16 ms | Between Coil De-energization and NO Contact Opening 4 ... 11 ms | Between Coil Energization and NC Contact Opening 7 ... 21 ms | Between Coil Energization and NO Contact Closing 10 ... 26 ms
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Auxiliary Circuit 1 N·m | Control Circuit 1 N·m | Main Circuit 1.2 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
General Use Rating UL/CSA
(600 V AC) 30 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 2 hp | (200 ... 208 V AC) Three Phase 7.5 hp | (220 ... 240 V AC) Three Phase 7.5 hp | (240 V AC) Single Phase 3 hp | (440 ... 480 V AC) Three Phase 15 hp | (550 ... 600 V AC) Three Phase 15 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 11 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 24 A | (200 ... 208 V AC) Three Phase 25.3 A | (220 ... 240 V AC) Three Phase 22 A | (240 V AC) Single Phase 17 A | (440 ... 480 V AC) Three Phase 21 A | (550 ... 600 V AC) Three Phase 17 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CB Certificate
AX 06~25A CB certification
CCC Certificate
9AKK107492A7089
CCS Certificate
CCS Certificate of AFC09 ... AFC96 , AX09-AX370 contactors
CQC Certificate
CQC Certificate, Contactor, AX06, AX09, AX12, AX18, AX25, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX06, AX09, AX12, AX18, AX25, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AX06, AX09, AX12, AX18, AX25, AX32, AX40, AX50, AX65, AX80 3-pole Contactors
UL Certificate
UL Certificate of Compliance – AX06, AX09, AX12, AX18, AX25
Package Level 1 Units
box 1 piece
Package Level 1 Width
48 mm
Package Level 1 Depth / Length
78 mm
Package Level 1 Height
79 mm
Package Level 1 Gross Weight
0.34 kg
Package Level 1 EAN
3471522397843
Package Level 2 Units
30 piece
Package Level 2 Width
240 mm
Package Level 2 Depth / Length
295 mm
Package Level 2 Height
145 mm
Package Level 2 Gross Weight
10.2 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
E-Number (Finland)
3707337
Three main NO contacts plus one auxiliary NO contact deliver clean, defined switching (Feature). This arrangement reduces mis-wiring and simplifies diagnostics during commissioning (Business Impact). Ideal for controlling 3-phase motors in conveyors and pumps (Application). Coil voltage of 110 V AC at 50/60 Hz (Feature). This standard coil voltage lowers spare-part complexity and ensures consistent energization across regional grids (Business Impact). Perfect for panel builders needing a versatile, globally compatible control coil (Application). Mains ratings include 690 V insulation and operation with AC-3 and AC-1 loads (Feature). It translates into predictable thermal performance and longer motor life (Business Impact). Suitable for contactor duties in line-start motors and similar loads in industrial sites (Application). Compact footprint: 44 mm wide, 74 mm deep, 76.3 mm high with IP20 terminals and screw terminals (Feature). This enables denser panel layouts and easier wiring (Business Impact). Helpful in space-constrained control cabinets for packaging, material handling, and process lines (Application). Low coil and contact power losses (1.2 W per pole AC-1; 0.35 W per pole AC-3) (Feature). Reduces heat generation and energy consumption in continuous duty cycles (Business Impact). Valuable in high-duty applications where efficiency margins matter (Application). Mounting flexibility and CAD compatibility (Feature). Accessory options like front or side-mounted auxiliary contact blocks (Impact). CAD drawings and data sheets support quick integration into mechanical designs (Application). Certifications and compliance (Feature). CE, UL, CCC, CQC, RoHS/REACH declarations provide regulatory alignment and easier procurement across international sites (Business Impact). Ideal for globally distributed manufacturing and system integrators (Application).

Get a Quick Quote for a ABB 1SBL931074R8410

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL931074R8410? Enquire Now

FAQs

This device uses a compact 44 mm width with screw terminals and IP20 protection. Plan for a 74 mm depth and 76.3 mm height footprint, secure torque values (Auxiliary 1 N·m; Control 1 N·m; Main 1.2 N·m), and ensure accessible wiring paths for front or side-mounted auxiliary blocks to optimize installation efficiency.
Rated Operational Current AC-3 at 690 V is 10 A (Thermal conditions 55 °C). At 415 V to 440 V variants, Ie can reach 16–25 A depending on voltage and ambient temperature. For AC-1, Ie ranges up to 32 A at 690 V and varies with voltage, ambient temperature, and duty cycle, aligning with typical motor starter applications.
Yes. The rated control circuit voltage is 50 Hz 110 V or 60 Hz 110–120 V, enabling reliable coil energization across regional grids. This AC-operated coil supports standard industrial control schemes and simplifies panel design when 110 V control is standard.
The contactor carries CE and UL certifications, along with RoHS/REACH declarations and related compliance marks (CCC, CQC). These certifications support global procurement, regulatory alignment, and reduce compliance risk for multinational installations.
Ideal for 3-phase motor control in conveyors, pumps, and processing lines. Benefits include a compact footprint, low coil power loss (1.2 W per pole AC-1; 0.35 W per pole AC-3), and compatibility with add-on auxiliary blocks and CAD data, which translates to energy efficiency, space savings, faster commissioning, and lower maintenance costs over the system life.