ABB 1SBL931074R8501 Block Contactor - 690V CE UL

Part Number: 1SBL931074R8501
Manufacturer
ABB
Part number
1SBL931074R8501

Quick Summary

ABB 1SBL931074R8501 Block Contactor controls 3-phase motors up to 690 V, delivering reliable switching in industrial automation. In many control cabinets, engineers face limited space and complex wiring that slows installation and increases failure risk. This model carries CE and UL/CSA approvals, CB and CCC declarations, plus RoHS and REACH compliance, helping you meet global regulatory requirements with confidence. Its compact 44 mm width and 74 mm depth support dense panel layouts, while screw terminals simplify field wiring and service. Add-on auxiliary contact blocks offer front or side mounting options for scalable control architecture, enabling fast adaptation as lines expand.

Product Information

Extended Description

1SBL931074R8501 ABB: AX09...AX25 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100187L0203
Instructions and Manuals
AX 06~40A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
44 mm
Product Net Depth / Length
74 mm
Product Net Height
76.3 mm
Product Net Weight
0.326 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
1
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 32 A | acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 55 °C 27 A | (690 V) 40 °C 32 A | (690 V) 70 °C 23 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 25 A | (440 V) 55 °C 16 A | (500 V) 55 °C 14 A | (690 V) 55 °C 10 A | (380 / 400 V) 55 °C 25 A | (220 / 230 / 240 V) 55 °C 25 A
Rated Operational Current AC-15 (Ie)
(500 V) NC 2 | (500 V) 2 A | (690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (380 / 400 V) 3 A | (400 / 440 V) 2 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (110 V) 1.1 A / 121 W | (125 V) 1.1 A / 138 W | (220 V) 0.55 A / 121 W | (250 V) 0.55 A / 138 W | (400 V) 2.8 A / 134 W | (500 V) 2 A / 144 W
Rated Operational Power AC-3 (Pe)
(415 V) 11 kW | (440 V) 9 kW | (500 V) 9 kW | (690 V) 9 kW | (380 / 400 V) 11 kW | (220 / 230 / 240 V) 6.5 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 200 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 32 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 85 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 105 A | for 0.1 s 140 A | for 1 s 100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-15) 1200 cycles per hour | (AC-3) 1200 cycles per hour | (DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 380 ... 400 V | 60 Hz 400 ... 415 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 1.2 W | at Rated Operating Conditions AC-3 per Pole 0.35 W
Operate Time
Between Coil De-energization and NC Contact Closing 9 ... 16 ms | Between Coil De-energization and NO Contact Opening 4 ... 11 ms | Between Coil Energization and NC Contact Opening 7 ... 21 ms | Between Coil Energization and NO Contact Closing 10 ... 26 ms
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Auxiliary Circuit 1 N·m | Control Circuit 1 N·m | Main Circuit 1.2 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
General Use Rating UL/CSA
(600 V AC) 30 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 2 hp | (200 ... 208 V AC) Three Phase 7.5 hp | (220 ... 240 V AC) Three Phase 7.5 hp | (240 V AC) Single Phase 3 hp | (440 ... 480 V AC) Three Phase 15 hp | (550 ... 600 V AC) Three Phase 15 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 11 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 24 A | (200 ... 208 V AC) Three Phase 25.3 A | (220 ... 240 V AC) Three Phase 22 A | (240 V AC) Single Phase 17 A | (440 ... 480 V AC) Three Phase 21 A | (550 ... 600 V AC) Three Phase 17 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CB Certificate
AX 06~25A CB certification
CCC Certificate
9AKK107492A7089
CCS Certificate
CCS Certificate of AFC09 ... AFC96 , AX09-AX370 contactors
CQC Certificate
CQC Certificate, Contactor, AX06, AX09, AX12, AX18, AX25, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX06, AX09, AX12, AX18, AX25, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AX06, AX09, AX12, AX18, AX25, AX32, AX40, AX50, AX65, AX80 3-pole Contactors
UL Certificate
UL Certificate of Compliance – AX06, AX09, AX12, AX18, AX25
Package Level 1 Units
box 1 piece
Package Level 1 Width
48 mm
Package Level 1 Depth / Length
78 mm
Package Level 1 Height
79 mm
Package Level 1 Gross Weight
0.34 kg
Package Level 1 EAN
3471522398857
Package Level 2 Units
30 piece
Package Level 2 Width
240 mm
Package Level 2 Depth / Length
295 mm
Package Level 2 Height
145 mm
Package Level 2 Gross Weight
10.2 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
The 1SBL931074R8501 provides three main normally open contacts with one built-in normally closed auxiliary contact, reducing wiring complexity and enabling a streamlined control scheme for 3-phase motors in conveyors, pumps, and machine tools. This feature translates to lower panel wiring time and improved connection reliability, directly impacting installation efficiency and downtime. The device is designed for global operation, supporting 50 Hz and 60 Hz systems with control voltage ranges up to 690 V, which simplifies procurement across sites and minimizes stocking of different variants. Its compact footprint—44 mm wide with a 74 mm depth and a 76.3 mm height—maximizes panel density, enabling more motors per cabinet without compromising accessibility. Screw terminals provide robust, vibration-resistant connections, while 1 N·m auxiliary and 1.2 N·m main-circuit tightening torques reduce service-time variation and maintenance costs. With IP20 protection, it's suited for clean, indoor environments and compatible with add-on auxiliary contact blocks for front or side mounting, reducing spare-parts variety. The contactor supports rapid coil operation: 9–16 ms (NC), 4–11 ms (NO closing to opening), and 10–26 ms (energization to closing), delivering precise motor starting and stop behavior for demanding automation lines. Operational power loss remains low—approximately 1.2 W per pole in AC-1 and 0.35 W per pole in AC-3—helping to minimize heat in control panels and extend component life. The maximum mechanical switching frequency of 3600 cycles per hour supports dynamic packaging lines, while electrical life at high currents is addressed by the device’s rated breaking capacity, which remains within safe limits for typical motor loads. This combination of performance and compatibility reduces total cost of ownership by enabling easy retrofits and fewer spare-part requirements. Long-term reliability is supported by RoHS, REACH, and CMRT declarations, ensuring compliant sourcing and responsible procurement for industrial facilities.

Get a Quick Quote for a ABB 1SBL931074R8501

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL931074R8501? Enquire Now

FAQs

This block contactor uses screw terminals for robust field wiring and supports add-on auxiliary contact blocks for front or side mounting. Its compact footprint (44 mm width, 74 mm depth) and IP20 protection simplify installation in dense control panels and reduce wiring complexity, making it ideal for space-constrained motor control applications.
The device provides three main normally open contacts and one NC auxiliary contact. Rated voltage supports up to 690 V with 50/60 Hz operation. Main circuit ratings include up to 32 A at 690 V (AC-3), while auxiliary circuits share the same voltage range for synchronized control, ensuring reliable performance for typical industrial motors.
Yes, the product is specified for ambient operation from -25 to 55 C with an overload relay, and up to 70 C without an OLR, with a maximum altitude of 3000 m without derating. For installations near equipment that elevates ambient temperature, choose configurations with appropriate thermal protection to maintain performance and longevity.
The model carries CE and UL/CSA approvals, CB certificates, and CCC declarations, supported by RoHS and REACH declarations. These certifications help meet global electrical safety and environmental requirements, simplifying cross-border procurement and compliance reporting for multinational plants.
With low power loss (1.2 W per pole in AC-1 and 0.35 W per pole in AC-3), fast operate times, and a robust IP20 design, maintenance intervals are extended and energy waste is minimized. Its compact footprint and compatibility with accessory blocks reduce panel space and spare parts, contributing to lower total cost of ownership and faster installation ROI on new lines.