ABB 1SBL931074R8610 Contactor - 690V, IP20, UL/CSA

Part Number: 1SBL931074R8610
Manufacturer
ABB
Part number
1SBL931074R8610

Quick Summary

ABB 1SBL931074R8610 Contactor is a compact three-pole device for controlling 3-phase motors up to 690 V AC. Engineers frequently confront space constraints, wiring complexity, and reliability challenges in compact switchgear and panels. This device carries CE marking, UL/CSA approvals, and IP20 protection to support safety, regulatory compliance, and dependable operation. Combined with AX-series compatibility and a broad accessory ecosystem, it enables faster installation and reduced lifecycle costs. It operates on 50 Hz or 60 Hz with a 400–415 V or 415–440 V control supply, and suits many panel designs. With 3 main NO contacts and 1 auxiliary NO contact, rated for up to 690 V and 50/60 Hz, it supports reliable conveyor, pump, and machine drives in demanding environments.

Product Information

Extended Description

1SBL931074R8610 ABB: AX09...AX25 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100187L0203
Instructions and Manuals
AX 06~40A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
44 mm
Product Net Depth / Length
74 mm
Product Net Height
76.3 mm
Product Net Weight
0.326 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
0
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 32 A | acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 55 °C 27 A | (690 V) 40 °C 32 A | (690 V) 70 °C 23 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 25 A | (440 V) 55 °C 16 A | (500 V) 55 °C 14 A | (690 V) 55 °C 10 A | (380 / 400 V) 55 °C 25 A | (220 / 230 / 240 V) 55 °C 25 A
Rated Operational Current AC-15 (Ie)
(500 V) NC 2 | (500 V) 2 A | (690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (380 / 400 V) 3 A | (400 / 440 V) 2 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (110 V) 1.1 A / 121 W | (125 V) 1.1 A / 138 W | (220 V) 0.55 A / 121 W | (250 V) 0.55 A / 138 W | (400 V) 2.8 A / 134 W | (500 V) 2 A / 144 W
Rated Operational Power AC-3 (Pe)
(415 V) 11 kW | (440 V) 9 kW | (500 V) 9 kW | (690 V) 9 kW | (380 / 400 V) 11 kW | (220 / 230 / 240 V) 6.5 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 200 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 32 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 85 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 105 A | for 0.1 s 140 A | for 1 s 100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-15) 1200 cycles per hour | (AC-3) 1200 cycles per hour | (DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 400 ... 415 V | 60 Hz 415 ... 440 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 1.2 W | at Rated Operating Conditions AC-3 per Pole 0.35 W
Operate Time
Between Coil De-energization and NC Contact Closing 9 ... 16 ms | Between Coil De-energization and NO Contact Opening 4 ... 11 ms | Between Coil Energization and NC Contact Opening 7 ... 21 ms | Between Coil Energization and NO Contact Closing 10 ... 26 ms
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Auxiliary Circuit 1 N·m | Control Circuit 1 N·m | Main Circuit 1.2 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
General Use Rating UL/CSA
(600 V AC) 30 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 2 hp | (200 ... 208 V AC) Three Phase 7.5 hp | (220 ... 240 V AC) Three Phase 7.5 hp | (240 V AC) Single Phase 3 hp | (440 ... 480 V AC) Three Phase 15 hp | (550 ... 600 V AC) Three Phase 15 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 11 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 24 A | (200 ... 208 V AC) Three Phase 25.3 A | (220 ... 240 V AC) Three Phase 22 A | (240 V AC) Single Phase 17 A | (440 ... 480 V AC) Three Phase 21 A | (550 ... 600 V AC) Three Phase 17 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CB Certificate
AX 06~25A CB certification
CCC Certificate
9AKK107492A7089
CCS Certificate
CCS Certificate of AFC09 ... AFC96 , AX09-AX370 contactors
CQC Certificate
CQC Certificate, Contactor, AX06, AX09, AX12, AX18, AX25, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX06, AX09, AX12, AX18, AX25, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AX06, AX09, AX12, AX18, AX25, AX32, AX40, AX50, AX65, AX80 3-pole Contactors
UL Certificate
UL Certificate of Compliance – AX06, AX09, AX12, AX18, AX25
Package Level 1 Units
box 1 piece
Package Level 1 Width
48 mm
Package Level 1 Depth / Length
78 mm
Package Level 1 Height
79 mm
Package Level 1 Gross Weight
0.34 kg
Package Level 1 EAN
3471522397867
Package Level 2 Units
30 piece
Package Level 2 Width
240 mm
Package Level 2 Depth / Length
295 mm
Package Level 2 Height
145 mm
Package Level 2 Gross Weight
10.2 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature → Business Impact → Application: 3 main NO contacts and 1 auxiliary NO contact simplify wiring and reduce component count, delivering a cleaner, more reliable motor control circuit with fewer failure points in customer conveyors and pumps. Application: Ideal for AX25-based motor control within machine lines where uptime matters and space is at a premium. Feature → Business Impact → Application: Rated operational voltage up to 690 V AC enables direct integration with global motors and drives, reducing voltage conversion needs and inventory complexity. Application: Global manufacturing lines and packaging equipment requiring universal motor control. Feature → Business Impact → Application: AC-3 and AC-1 current ratings (Ie up to 32 A at 690 V and up to 25 A at higher line voltages) support standard industrial motors, enabling compact drives with predictable thermal performance. Application: Fans, pumps, conveyors in process automation. Feature → Business Impact → Application: Power loss around 1.2 W per pole at AC-1 and 0.35 W per pole at AC-3 improves energy efficiency and reduces panel heat, supporting maintenance windows and energy targets. Application: Continuous operation in control cabinets. Feature → Business Impact → Application: 44 mm width, 74 mm depth, 76.3 mm height with screw terminals enables easy retrofit and compact panel design, plus add-on auxiliary blocks for front or side mounting. Application: Retrofit projects and new builds seeking flexible wiring layouts. Feature → Business Impact → Application: IP20 protection for auxiliary and main terminals and robust insulation up to 690 V ensure safe operation in typical industrial environments, reducing risk during maintenance. Application: Food & beverage, packaging, and material handling lines with open cabinet exposure. Feature → Business Impact → Application: CE, UL/CSA certifications, and RoHS/REACH compliance simplify regulatory approvals and supplier qualification. Application: OEMs targeting global markets and multi-site deployments.

Get a Quick Quote for a ABB 1SBL931074R8610

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL931074R8610? Enquire Now

FAQs

Compatibility is streamlined by its 44 mm width, 74 mm depth, and 76.3 mm height, matching standard AX frames. Screw terminals use 1 N·m for auxiliary/control and 1.2 N·m for main terminals, with options for add-on auxiliary blocks for front or side mounting. This supports fast retrofits or new builds with minimal wiring complexity.
Rated Operational Current AC-1 is up to 32 A at 690 V, while AC-3 can be 25 A at 415 V, 16 A at 440 V, 14 A at 500 V, and 10 A at 690 V. Rated Power AC-3 reaches up to 11 kW at 415 V and 9 kW at 440–690 V. The device features 3 NO main contacts and 1 NO auxiliary contact, with operation at 50/60 Hz.
Yes, it carries CE marking and UL/CSA certifications, including a UL certificate for AX series. It provides IP20 protection for main, auxiliary, and control terminals, and complies with IEC 60947-4-1/5-1 and RoHS/REACH requirements for safe industrial use.
The device has a 44 mm net width, 74 mm net depth, and 76.3 mm net height, with screw-terminal mounting. It supports front or side-mounted add-on auxiliary blocks, enabling flexible wiring schemes and easier installation in compact panels or retrofit projects.
Maximum mechanical switching frequency is 3600 cycles per hour; electrical switching frequencies are 600 cycles per hour for AC-1, 1200 cycles per hour for AC-3, and up to 900 cycles per hour for DC-13, aligning with typical industrial duty cycles for conveyors, pumps, and power supplies.