ABB 1SBL931074R8801 Block Contactor - CE UL Certified
Part Number: 1SBL931074R8801
Quick Summary
ABB 1SBL931074R8801 Block Contactor is a three-pole AC switch designed to control 3‑phase motors up to 690 V in industrial automation environments. This compact device helps address space constraints in control panels while delivering reliable switching performance. It carries key certifications such as CE, UL and CCC/CQC, supporting global compliance and market access. RoHS and REACH declarations further enhance procurement confidence. For engineers and procurement teams, the combination of a compact footprint, robust ratings and broad accessory compatibility translates into reduced panel real estate, lower installation costs and easier future upgrades in motor control and conveyor applications.
Product Information
Extended Description
1SBL931074R8801 ABB: AX09...AX25 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100187L0203
Instructions and Manuals
AX 06~40A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
44 mm
Product Net Depth / Length
74 mm
Product Net Height
76.3 mm
Product Net Weight
0.326 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
1
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 32 A | acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 55 °C 27 A | (690 V) 40 °C 32 A | (690 V) 70 °C 23 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 25 A | (440 V) 55 °C 16 A | (500 V) 55 °C 14 A | (690 V) 55 °C 10 A | (380 / 400 V) 55 °C 25 A | (220 / 230 / 240 V) 55 °C 25 A
Rated Operational Current AC-15 (Ie)
(500 V) NC 2 | (500 V) 2 A | (690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (380 / 400 V) 3 A | (400 / 440 V) 2 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (110 V) 1.1 A / 121 W | (125 V) 1.1 A / 138 W | (220 V) 0.55 A / 121 W | (250 V) 0.55 A / 138 W | (400 V) 2.8 A / 134 W | (500 V) 2 A / 144 W
Rated Operational Power AC-3 (Pe)
(415 V) 11 kW | (440 V) 9 kW | (500 V) 9 kW | (690 V) 9 kW | (380 / 400 V) 11 kW | (220 / 230 / 240 V) 6.5 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 200 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 32 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 85 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 105 A | for 0.1 s 140 A | for 1 s 100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-15) 1200 cycles per hour | (AC-3) 1200 cycles per hour | (DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 230 ... 240 V | 60 Hz 240 ... 260 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 1.2 W | at Rated Operating Conditions AC-3 per Pole 0.35 W
Operate Time
Between Coil De-energization and NC Contact Closing 9 ... 16 ms | Between Coil De-energization and NO Contact Opening 4 ... 11 ms | Between Coil Energization and NC Contact Opening 7 ... 21 ms | Between Coil Energization and NO Contact Closing 10 ... 26 ms
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Auxiliary Circuit 1 N·m | Control Circuit 1 N·m | Main Circuit 1.2 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
General Use Rating UL/CSA
(600 V AC) 30 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 2 hp | (200 ... 208 V AC) Three Phase 7.5 hp | (220 ... 240 V AC) Three Phase 7.5 hp | (240 V AC) Single Phase 3 hp | (440 ... 480 V AC) Three Phase 15 hp | (550 ... 600 V AC) Three Phase 15 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 11 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 24 A | (200 ... 208 V AC) Three Phase 25.3 A | (220 ... 240 V AC) Three Phase 22 A | (240 V AC) Single Phase 17 A | (440 ... 480 V AC) Three Phase 21 A | (550 ... 600 V AC) Three Phase 17 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CB Certificate
AX 06~25A CB certification
CCC Certificate
9AKK107492A7089
CCS Certificate
CCS Certificate of AFC09 ... AFC96 , AX09-AX370 contactors
CQC Certificate
CQC Certificate, Contactor, AX06, AX09, AX12, AX18, AX25, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX06, AX09, AX12, AX18, AX25, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AX06, AX09, AX12, AX18, AX25, AX32, AX40, AX50, AX65, AX80 3-pole Contactors
UL Certificate
UL Certificate of Compliance – AX06, AX09, AX12, AX18, AX25
Package Level 1 Units
box 1 piece
Package Level 1 Width
48 mm
Package Level 1 Depth / Length
78 mm
Package Level 1 Height
79 mm
Package Level 1 Gross Weight
0.34 kg
Package Level 1 EAN
3471522398888
Package Level 2 Units
30 piece
Package Level 2 Width
240 mm
Package Level 2 Depth / Length
295 mm
Package Level 2 Height
145 mm
Package Level 2 Gross Weight
10.2 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature: Three main NO contacts with one NC auxiliary contact simplifies motor control and feedback paths. Impact: Reduces wiring complexity and potential fault points, enabling quicker commissioning and easier diagnostics in automated lines. Application: Ideal for controlling three‑phase motors in conveyors and pumps where clear status signaling is required. Feature: Block-type design with a compact 44 mm width and 74 mm depth. Impact: Enables denser panel layouts, lower enclosure costs, and simplified thermal management. Application: Suitable for compact automation cabinets and space-limited installations in manufacturing lines. Feature: AC-operated control circuit with 230–240 V at 50 Hz or 240–260 V at 60 Hz. Impact: Broad compatibility across regional DC bus and control voltages reduces the need for transformers. Application: Global motor control panels and cross‑regional equipment deployments. Feature: Rated Operational Current AC‑3 up to 32 A at 690 V (with 55–70 °C ambient variants). Impact: Supports medium‑duty motor loads with predictable interrupting performance and reliable cycling. Application: Soft-start/Direct-on-line motor drives in industrial facilities. Feature: IP20 protection for auxiliaries and mains terminals with screw terminals and a 1 N·m tightening torque for auxiliary and control circuits. Impact: Safer wiring, consistent torque, and straightforward retrofits or upgrades. Application: Panel mounting in clean, indoor industrial environments. Feature: Comprehensive certifications (CE, UL/CSA, CCC/CQC, RoHS/REACH). Impact: Enables global procurement and compliance assurance across multiple regions. Application: Global supply chains and regulated industries such as food + beverage, packaging, and process automation. Insight: Access to CAD dimensional drawings, 2D/3D files, and add-on auxiliary blocks streamlines engineering workflows, reduce engineering change orders, and supports faster time-to-value for new line builds.
Get a Quick Quote for a ABB 1SBL931074R8801
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SBL931074R8801?
Enquire Now
FAQs
Installation should start with verifying the 44 mm width, 74 mm depth, and 76.3 mm height to ensure a proper fit in the enclosure. Use screw terminals for main and auxiliary circuits, tighten auxiliary and control circuit terminals to 1 N·m, and main circuit terminals to 1.2 N·m. Ensure ambient temperature does not exceed 70 °C and respect IP20 protection guidelines for safe operation. Include add-on auxiliary blocks if interlocking or signaling is required and reference the CAD drawings for exact mounting positions. This approach reduces wiring errors and accelerates commissioning in new builds or retrofits.
For AC-3 operation at 690 V, the contactor provides up to 10 A continuous with 32 A short-time withstand capacity, enabling reliable motor switching. For AC-1 applications, it supports up to 27 A at 240 V and higher current ratings for other voltage combinations, such as 25 A at 415 V and 25 A at 380/400 V. These ratings make the device suitable for starting and controlled stopping of medium‑sized motors in process lines and material handling equipment.
The product is designed for indoor panel mounting with IP20 protection for terminations and contacts. It is specified to operate in ambient temperatures from −25 °C to 55 °C when fitted with a thermal overload relay, and up to −40 °C to 70 °C near the contactor. It supports operation up to 3000 m altitude without derating. For harsher environments or external enclosures, use appropriate enclosures and consider a compatible thermal overload module to optimize operation.
This contactor carries CE and UL/CSA listings, along with CCC/CQC declarations and RoHS/REACH compliance. These certifications ensure compliance with European and North American electrical safety standards, support environmental responsibility, and simplify regulatory approvals in multinational sites. For regulated industries, these certifications help validate supplier reliability, reduce compliance risk, and streamline procurement across global projects.
Expect reliable operation with a rated mechanical switching frequency up to 3600 cycles per hour, and electrical switching up to 1200 cycles per hour depending on the load type (AC-1, AC-3, DC‑13). Regular inspection should include tightening torque verification at 1 N·m for auxiliary and control circuits and 1.2 N·m for main terminals, checking insulation, and ensuring add-on auxiliary blocks remain properly mounted. With proper sizing and periodic checks, the unit provides consistent performance in conveyors, pumps, and other common automation tasks.