ABB 1SBL931074R8810 Block Contactor - UL/CSA 600V 30A
Part Number: 1SBL931074R8810
Quick Summary
ABB 1SBL931074R8810 Block Contactor is designed to reliably switch three‑phase motors in industrial power circuits up to 690 V. Operators often struggle with limited panel space, thermal wear, and unpredictable switching under varying ambient temperatures. This device delivers CE conformity, UL/CSA listings, and RoHS/REACH compliance to support safe, compliant integration in modern control panels. Its compact block design with add‑on auxiliary contacts simplifies wiring and streamlines installation, while CAD‑ready dimensions help accelerate panel design and project timelines.
Product Information
Extended Description
1SBL931074R8810 ABB: AX09...AX25 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100187L0203
Instructions and Manuals
AX 06~40A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
44 mm
Product Net Depth / Length
74 mm
Product Net Height
76.3 mm
Product Net Weight
0.326 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
0
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 32 A | acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 55 °C 27 A | (690 V) 40 °C 32 A | (690 V) 70 °C 23 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 25 A | (440 V) 55 °C 16 A | (500 V) 55 °C 14 A | (690 V) 55 °C 10 A | (380 / 400 V) 55 °C 25 A | (220 / 230 / 240 V) 55 °C 25 A
Rated Operational Current AC-15 (Ie)
(500 V) NC 2 | (500 V) 2 A | (690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (380 / 400 V) 3 A | (400 / 440 V) 2 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (110 V) 1.1 A / 121 W | (125 V) 1.1 A / 138 W | (220 V) 0.55 A / 121 W | (250 V) 0.55 A / 138 W | (400 V) 2.8 A / 134 W | (500 V) 2 A / 144 W
Rated Operational Power AC-3 (Pe)
(415 V) 11 kW | (440 V) 9 kW | (500 V) 9 kW | (690 V) 9 kW | (380 / 400 V) 11 kW | (220 / 230 / 240 V) 6.5 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 200 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 32 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 85 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 105 A | for 0.1 s 140 A | for 1 s 100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-15) 1200 cycles per hour | (AC-3) 1200 cycles per hour | (DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 230 ... 240 V | 60 Hz 240 ... 260 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 1.2 W | at Rated Operating Conditions AC-3 per Pole 0.35 W
Operate Time
Between Coil De-energization and NC Contact Closing 9 ... 16 ms | Between Coil De-energization and NO Contact Opening 4 ... 11 ms | Between Coil Energization and NC Contact Opening 7 ... 21 ms | Between Coil Energization and NO Contact Closing 10 ... 26 ms
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Auxiliary Circuit 1 N·m | Control Circuit 1 N·m | Main Circuit 1.2 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
General Use Rating UL/CSA
(600 V AC) 30 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 2 hp | (200 ... 208 V AC) Three Phase 7.5 hp | (220 ... 240 V AC) Three Phase 7.5 hp | (240 V AC) Single Phase 3 hp | (440 ... 480 V AC) Three Phase 15 hp | (550 ... 600 V AC) Three Phase 15 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 11 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 24 A | (200 ... 208 V AC) Three Phase 25.3 A | (220 ... 240 V AC) Three Phase 22 A | (240 V AC) Single Phase 17 A | (440 ... 480 V AC) Three Phase 21 A | (550 ... 600 V AC) Three Phase 17 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CB Certificate
AX 06~25A CB certification
CCC Certificate
9AKK107492A7089
CCS Certificate
CCS Certificate of AFC09 ... AFC96 , AX09-AX370 contactors
CQC Certificate
CQC Certificate, Contactor, AX06, AX09, AX12, AX18, AX25, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX06, AX09, AX12, AX18, AX25, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AX06, AX09, AX12, AX18, AX25, AX32, AX40, AX50, AX65, AX80 3-pole Contactors
UL Certificate
UL Certificate of Compliance – AX06, AX09, AX12, AX18, AX25
Package Level 1 Units
box 1 piece
Package Level 1 Width
48 mm
Package Level 1 Depth / Length
78 mm
Package Level 1 Height
79 mm
Package Level 1 Gross Weight
0.34 kg
Package Level 1 EAN
3471522397881
Package Level 2 Units
30 piece
Package Level 2 Width
240 mm
Package Level 2 Depth / Length
295 mm
Package Level 2 Height
145 mm
Package Level 2 Gross Weight
10.2 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature: 3 main NO contacts plus 1 built‑in auxiliary NO contact. Business Impact: Simplifies motor control wiring and reduces component count. Application: Ideal for starting/stopping 3‑phase motors in conveyors and pumps. Feature: Control circuit is AC operated with add‑on auxiliary contact blocks for front or side mounting. Business Impact: Flexible installation and scalable control architecture. Application: Enables modular control in compact panels and big‑box assemblies. Feature: Rated operational voltage up to 690 V and IP20 protection on terminals. Business Impact: Broad compatibility with European and global mains and safe, accessible wiring. Application: Suitable for harsh industrial environments where safe termination matters. Feature: Rated Operational Current AC‑1 up to 32 A at 690 V; AC‑3 up to 25 A at 415–690 V; DC‑13 up to 2–6 A depending on voltage. Business Impact: Supports common motor and load profiles with predictable performance. Application: Pumps, fans, and machine tools with varying load profiles. Feature: Robust electrical/mechanical life and high short‑term withstand. Business Impact: Reduces maintenance cycles and downtime, improving overall uptime. Application: Repeated cycling in automated lines and packaging systems. Feature: Comprehensive certifications and compliance (UL/CSA, CE, RoHS, REACH, TSCA). Business Impact: Simplifies regulatory clearance and customer audits. Application: Seamless integration into regulated manufacturing environments. Feature: Compact dimensions (44 mm wide, 74 mm deep, 76.3 mm high) and low weight (0.326 kg). Business Impact: Easier chassis integration and reduced panel footprint. Application: Space‑constrained control cabinets and modular machine designs.
Get a Quick Quote for a ABB 1SBL931074R8810
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SBL931074R8810?
Enquire Now
FAQs
The 1SBL931074R8810 supports front and side mounting with add‑on auxiliary contact blocks, enabling flexible installation in compact control panels. Its 44 mm width and standard screw terminals make it straightforward to integrate into existing DIN rail or panel layouts, reducing wiring complexity and installation time.
For AC‑1 operation, the device is rated up to 32 A at 690 V (and 27 A at 240 V under typical ambient conditions). For AC‑3 operation, ratings reach up to 25 A at 415–690 V. These values vary with ambient temperature and installation conditions, so select the appropriate Ie based on your load and voltage.
Yes. With three main NO contacts and one auxiliary contact, a 690 V maximum voltage, and IEC/UL/CSA compliance, the 1SBL931074R8810 is well suited for 3‑phase motor control in pumps, conveyors, and general purpose industrial drives. Its compact form factor simplifies panel design while meeting typical motor start/stop needs.
The product carries UL/CSA ratings for 600 V class, CE declarations of conformity, and RoHS/REACH compliance, along with TSCA statements where applicable. It also aligns with international standards for block contactors, helping streamline regulatory reviews and customer audits.
Plan for periodic inspection of the coil and contacts, with attention to contact wear in high‑cycle applications. The device supports high mechanical switching frequency and provides build‑in reliability with robust insulation. Keep terminals tight (1 N·m auxiliary, control, and main) and use compatible auxiliary blocks to maintain performance over time.