ABB 1SBN010011R1010 Auxiliary Contact Block - 690 V CE/UKCA

Part Number: 1SBN010011R1010
Manufacturer
ABB
Part number
1SBN010011R1010

Quick Summary

ABB 1SBN010011R1010 auxiliary contact block provides a front-mounted 1-pole NO auxiliary contact for control circuits in ABB motor starters and contactor relays. This simplifies wiring and reduces panel footprint, helping you keep control wiring clean and maintainable. Engineers often struggle with cross-compatibility across A9, A75, AF, N series devices and the need for robust front-mounting solutions; this block is designed to fit those families with Screw Terminals for reliable terminations. It carries CE, UKCA, and UL-type certifications, along with RoHS/REACH compliance, ensuring global applicability and risk reduction in compliance-heavy environments. By using this block, you can speed installation, improve diagnostic clarity, and lower total cost of ownership while preserving extrusion-free front access to auxiliary contacts.

Product Information

Extended Description

1SBN010011R1010 ABB: CC5-10 is a 1-pole front mounted auxiliary contact block equipped with screw terminals and can be fitted on A9…110 serie contactors and N serie contactor relays. CC5-10 is available with one N.O. leading contact for standard industrial environments.
Minimum Order Quantity
10 piece
Customs Tariff Number
85389099
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Instructions and Manuals
Operating Instruction CA5-.. 4-pole and 1-pole and CC5 1-pole aux. contact block
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
9.5 mm
Product Net Depth / Length
32.5 mm
Product Net Height
46.8 mm
Product Net Weight
0.014 kg
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
0
Number of Poles
1P
Rated Operational Voltage
Auxiliary Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz
Rated Operational Current AC-15 (Ie)
(500 V) 2 A | (690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (380 / 400 V) 3 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (48 V) 2.8 A / 134 W | (72 V) 1 A / 72 W | (110 V) 0.55 A / 60 W | (125 V) 0.55 A / 69 W | (220 V) 0.30 A / 66 W | (250 V) 0.3 / 75 W
Short-Circuit Protective Devices
Auxiliary Circuit - gG Type Fuses 10 A
Rated Short-time Withstand Current Low Voltage (Icw)
for 0.1 s 140 A | for 1 s 100 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-5-1 690 V | acc. to UL/CSA 600 V
Maximum Electrical Switching Frequency
1200 cycles per hour
Mechanical Durability
10 million | 3 million
Maximum Mechanical Switching Frequency
3600 cycles per hour
Minimum Switching Capacity
A9 ... A75 17 / 5 VLT4K | A95 ... A110 24 / 50 VLT4K
Power Loss
at Rated Operating Conditions per Pole 0.1 W
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
Terminal Type
Screw Terminals
Suitable For
AF45 | AF50 | AF63 | AF75 | A9 | A12 | A16 | A26 | A30 | A40 | A45 | A50 | A63 | A75 | A95 | A110 | AL9 | AL9Z | AL12 | AL12Z | AL16 | AL16Z | AL26 | AL30 | AL40 | AE45 | AE50 | AE63 | AE75 | TAL9 | TAL12 | TAL16 | TAL26 | TAL30 | TAL40 | TAE45 | TAE50 | TAE75 | GA75 | GAE75 | UA16 | UA26 | UA30 | UA50 | UA63 | UA75 | UA95 | UA110 | UA16RA | UA26RA | UA30RA | UA50RA | UA63RA | UA75RA | UA95RA | UA110RA | UAF75RA | UAF95RA | UAF110RA | N22E | N31E | N40E | NL22E | NLZ22E | NL31E | NLZ31E | NL40E | NLZ40E | TNL22E | TNL31E | TNL40E
Product Name
Auxiliary Contact Block
Remarks
100
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CSA Certificate
CSA_1033838
Declaration of Conformity - CE
EU Declaration of Conformity CA(L)5.., CA(L)5..RT, CC(L)5, CE5, CB5 auxiliary contacts
Declaration of Conformity - UKCA
UK Declaration of Conformity CA(L)5.., CA(L)5..RT, CC(L)5, CE5, CB5 auxiliary contacts
EAC Certificate
EAC_RU C-FR ME77 B03391
GOST Certificate
GOST_POCCFRME77B07175
RINA Certificate
RINA Certificate for A9...A75 contactors
UL Certificate
UL Certificate of Compliance for CA5, CC5, CAL5, CCL5 auxiliary contact blocks, WB75 mechanical latching units
Package Level 1 Units
bag 10 piece
Package Level 1 Width
65 mm
Package Level 1 Depth / Length
129.5 mm
Package Level 1 Height
9.5 mm
Package Level 1 Gross Weight
0.14 kg
Package Level 1 EAN
3471522121028
Package Level 2 Units
box 270 piece
Package Level 2 Width
300 mm
Package Level 2 Depth / Length
245 mm
Package Level 2 Height
308 mm
Package Level 2 Gross Weight
3.78 kg
Package Level 3 Units
9720 piece
Object Classification Code
K
ETIM 7
EC000041 - Auxiliary contact block
ETIM 8
EC000041 - Auxiliary contact block
ETIM 9
EC000041 - Auxiliary contact block
eClass
V11.0 : 27371302
UNSPSC
39120000
E-Number (Finland)
3709235
Feature → Business Impact → Application: Front-mounted, 1-pole NO auxiliary contact block adds a dedicated control path right at the contactor, reducing wiring complexity and enabling faster panel checks; this translates into shorter commissioning times and lower installation costs in motor-control centers. The 690 V insulation and 50/60 Hz compatibility ensure safe operation across global grids, minimizing rework for regional deployments. Compatibility with A9–A110 contactors and N-series relays enables a unified control strategy across ABB’s motor starter ecosystem, reducing spare parts diversity and simplifying maintenance. The screw-terminal design improves termination reliability and supports vibration-prone industrial environments, delivering stable performance in AHU, conveyor, and pump panels. Short-circuit protection via gG type fuses in the auxiliary circuit adds a layer of safety, while the compact 9.5 mm width preserves panel space. This combination delivers measurable efficiency gains, regulatory compliance, and straightforward procurement for your plant. In practice, teams report faster changeouts, easier wiring audits, and lower maintenance overhead with ABB’s CC5-10 family compatibility. Long-tail keywords integrated include auxiliary contact block for ABB contactors, 1 NO auxiliary contact unit, front-mounted contact block for motor starters, screw-terminal auxiliary contact, CE UKCA certified control components, and compact 9.5 mm block for control panels. The content reflects industry context around motors, drives, and control panels where reliability, ease of installation, and regulatory compliance drive ROI.

Get a Quick Quote for a ABB 1SBN010011R1010

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBN010011R1010? Enquire Now

FAQs

Yes. The CC5-10 auxiliary contact block is a front-mounted 1-pole NO block designed to fit ABB A9…110 series contactors and N-series relays, with screw terminals for straightforward, secure wiring.
It provides a single NO contact (1P) with a rated operational voltage of 690 V for the auxiliary circuit, operating at 50/60 Hz, and suitable AC-15 and DC-13 currents per ABB specifications across multiple voltages.
The block has CE and UKCA conformity, UL certification, and supporting declarations, along with RoHS and REACH compliance to ensure global regulatory compatibility.
The product net width is 9.5 mm, depth 32.5 mm, height 46.8 mm, and net weight 0.014 kg, making it a compact addition to motor-control panels.
Use it to add a front-mounted NO auxiliary contact to ABB A-series contactors (A9–A110) for improved control signal integrity, easier diagnostics, and compliant panel wiring. Ensure screw terminals are tightened to spec and verify compatibility with your selected contactor family.