ABB 1SBN019040R1340 Auxiliary Contact Block - CE 690V
Part Number: 1SBN019040R1340
Quick Summary
ABB 1SBN019040R1340 Auxiliary Contact Block adds 4 normally open contacts for AX contactors in control panels. In dense automation cabinets, signaling reliability and wiring clarity are common pain points, and this block helps reduce mis-signaling and field wiring errors. The unit complies with CE, RoHS, and REACH standards, with additional TSCA and EAC declarations for broader markets, supporting regulatory confidence across Europe, the Americas, and beyond. Its compact footprint and screw-terminal design streamline installation, while ensuring robust performance in standard industrial environments. Built for fast replacement and scalable signaling, it pairs effectively with AX06 through AX40 contactors, delivering predictable interlocks and status feedback in modern control systems.
Product Information
Extended Description
1SBN019040R1340 ABB: CA5X-40U is a 4-pole front mounted auxiliary contact block equipped with screw terminals. CA5X-..U version offers terminal assortment matching the marking of 3-pole AX06..40-30-01 contactors. CA5X-40U is available with 4 N.O. and 0 N.C. instantaneous contacts for standard industrial environments.
Minimum Order Quantity
2 piece
Customs Tariff Number
85030099
Data Sheet, Technical Information
1SBC100187L0203
Instructions and Manuals
1SBC101044M9801
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
43 mm
Product Net Depth / Length
32.5 mm
Product Net Height
47 mm
Product Net Weight
0.06 kg
Number of Auxiliary Contacts NO
4
Number of Auxiliary Contacts NC
0
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-15 (Ie)
(690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (380 / 400 V) 3 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (110 V) 0.55 A / 60 W | (125 V) 0.55 A / 69 W | (220 V) 0.30 A / 66 W | (250 V) 0.30 A / 75 W | (400 V) 2.8 A / 134 W | (500 V) 1 A / 72 W
Rated Short-time Withstand Current Low Voltage (Icw)
for 0.1 s 140 A | for 1 s 100 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V
Maximum Electrical Switching Frequency
(AC-15) 1200 cycles per hour | (DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Terminal Type
Screw Terminals
Suitable For
AX06 | AX09 | AX12 | AX18 | AX25 | AX32 | AX40
Product Name
Auxiliary Contact Block
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CCC Certificate
CCC_2014010304725046
CQC Certificate
CQC Certificate, Auxiliary contacts, CA5X-***, Made in India
Declaration of Conformity - CCC
CCC Declaration of Conformity, Auxiliary contacts, CA5X-***, Made in India
Declaration of Conformity - CE
EU Declaration of Conformity CA5X.., CAL5X.., auxiliary contacts
EAC Certificate
EAC_RU C-DE ME77 B03562
Package Level 1 Units
box 2 piece
Package Level 1 Width
65 mm
Package Level 1 Depth / Length
130 mm
Package Level 1 Height
40 mm
Package Level 1 Gross Weight
0.12 kg
Package Level 1 EAN
3471522387837
Package Level 2 Units
120 piece
Package Level 2 Width
220 mm
Package Level 2 Depth / Length
380 mm
Package Level 2 Height
300 mm
Package Level 2 Gross Weight
7.2 kg
Object Classification Code
K
ETIM 7
EC000041 - Auxiliary contact block
ETIM 8
EC000041 - Auxiliary contact block
ETIM 9
EC000041 - Auxiliary contact block
eClass
V11.0 : 27371302
UNSPSC
39121500
IDEA Granular Category Code (IGCC)
4743 >> Auxiliary contact block
Feature → Business Impact → Application: The CA5X-40U-compatible auxiliary block provides four NO contacts and 690 V ratings, which translates into reliable signaling for AX06–AX40 contactors in plant control circuits, improving interlock reliability and reducing wiring complexity in machine automation. Application: signaling and status feedback in control panels. Feature → Business Impact → Application: Four normally open contacts with front-mounted screw terminals simplify field wiring, shorten commissioning time, and enable quick diagnostics, reducing on-site labor costs and downtime. Application: low-profile signaling modules in compact automation cabinets. Feature → Business Impact → Application: Compact 43 mm width, 32.5 mm depth, 47 mm height, and 0.06 kg weight enable dense panel layouts without compromising performance, improving space efficiency and airflow in electrical enclosures. Application: space-constrained control panels and modular automation setups. Feature → Business Impact → Application: Compatibility with AX06–AX40 contactors ensures scalable signaling across multiple machine configurations, supporting standardization and inventory simplification. Application: modular control architectures and retrofit projects. Feature → Business Impact → Application: IEC 60947-5-1 compliance, 16 A Ith, AC-15 up to 690 V at 2 A and DC-13 up to 400 V at 2.8 A, plus 0.1–1 s short-time withstand current, provides predictable performance and regulatory confidence for industrial installations. Application: high-reliability signaling in control circuits.
Get a Quick Quote for a ABB 1SBN019040R1340
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SBN019040R1340?
Enquire Now
FAQs
Install the CA5X-40U-compatible auxiliary block by aligning it with AX06–AX40 contactors in front-mounted slots and securing the screw terminals. Ensure wiring conforms to the 43 mm by 32.5 mm footprint and standard conductor sizes. The 2 piece minimum order helps with project phasing, while the screw terminals simplify field terminations and debugging during commissioning.
AC-15 ratings at 690 V are up to 2 A, with lower voltages allowing higher currents (24/127 V up to 6 A, 220/240 V up to 4 A, 380/400 V up to 3 A). DC-13 ratings vary by voltage, including 24 V at 6 A (144 W) and 400 V at 2.8 A (134 W), with higher DC voltages offering reduced currents to stay within safety margins.
Yes. With four normally open contacts and front-mounted screw terminals, the block provides clear signaling and reliable interlocking for AX06–AX40 contactors in machine control panels. The 690 V rating and IEC 60947-5-1 compliance support standard industrial environments, while the compact footprint helps when panel space is tight. It also simplifies maintenance and troubleshooting.
The auxiliary block carries CE, RoHS, and REACH declarations, with TSCA compliance and CCC/CQC certifications, plus EAC support for Eurasian markets. WEEE B2B classification confirms proper end-of-life handling, and CMRT information helps with sustainability reporting. This breadth of compliance supports global deployments and supplier audits.
By expanding AX contactors with 4 NO auxiliary contacts, you gain enhanced signaling reliability, reduce wiring errors, and shorten commissioning. The screw-terminal design speeds field terminations, while the compact 0.06 kg form factor minimizes panel load. Long-term maintenance is simplified, contributing to lower downtime and higher overall equipment effectiveness (OEE).