ABB 1SBX203301R1222 Contactor Starter - IEC 60947-4-1

Part Number: 1SBX203301R1222
Manufacturer
ABB
Part number
1SBX203301R1222

Quick Summary

ABB Contactor Starter is a compact motor control solution for three-pole loads in industrial automation. Engineers often contend with space constraints and wiring complexity in control panels. This ABB unit complies with IEC/EN 60947-1 and IEC/EN 60947-4-1 and carries UL/CSA listings for global installations. Designed for 48-130 V control circuits and 690 V mains, it reduces panel clutter while delivering dependable switching performance. By integrating main and auxiliary contacts in a DIN-rail footprint, it lowers installation time and total cost of ownership. It’s well-suited for factory automation, conveyors, pumps, and process equipment.

Product Information

Extended Description

1SBX203301R1222 ABB: AF12R-30-22-12 48-130V50/60HZ-DC Reversing Contactor
Minimum Order Quantity
1 piece
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
90 mm
Product Net Depth / Length
102.5 mm
Product Net Height
104 mm
Product Net Weight
0.662 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-4-1
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Control Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Rated Operational Current AC-1 (Ie)
(1000 V) 60 °C 28 A | (690 V) 40 °C 28 A | (690 V) 70 °C 24 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 12 A | (440 V) 60 °C 12 A | (500 V) 60 °C 12.5 A | (690 V) 60 °C 9 A | (380 / 400 V) 60 °C 12 A | (220 / 230 / 240 V) 60 °C 12 A
Rated Operational Current AC-3e (Ie)
(415 V) 60 °C 12 A | (440 V) 60 °C 12 A | (500 V) 60 °C 12.5 A | (690 V) 60 °C 9 A | (380 / 400 V) 60 °C 12 A | (220 / 230 / 240 V) 60 °C 12 A
Rated Operational Current AC-15 (Ie)
(500 V) 2 A | (690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (400 / 440 V) 3 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (48 V) 2.8 A / 134 W | (72 V) 1 A / 72 W | (110 V) 0.55 A / 60 W | (125 V) 0.55 A / 69 W | (220 V) 0.27 A / 60 W | (250 V) 0.27 A / 68 W | (400 V) 0.15 A / 60 W | (500 V) 0.13 A / 65 W | (600 V) 0.1 A / 60 W
Rated Operational Power AC-3 (Pe)
(415 V) 5.5 kW | (440 V) 5.5 kW | (500 V) 7.5 kW | (690 V) 7.5 kW | (380 / 400 V) 5.5 kW | (220 / 230 / 240 V) 3 kW
Rated Operational Power AC-3e (Pe)
(415 V) 5.5 kW | (440 V) 5.5 kW | (500 V) 7.5 kW | (690 V) 7.5 kW | (380 / 400 V) 5.5 kW | (220 / 230 / 240 V) 3 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 150 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 35 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A | for 0.1 s 140 A | for 1 s 100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 690 V | acc. to IEC 60947-5-1 690 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
6 kV
Maximum Electrical Switching Frequency
(AC-15) 1200 cycles per hour | (DC-13) 900 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 48 ... 130 V | 60 Hz 48 ... 130 V | DC Operation 48 ... 130 V
Power Loss
at 6 A per Pole 0.1 W | at Rated Operating Conditions AC-1 per Pole 1 W | at Rated Operating Conditions AC-3 per Pole 0.2 W
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 0.75 ... 6 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 4 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | Rigid Solid 1/2x 1 ... 4 mm² | Rigid Stranded 1/2x 1 ... 6 mm²
Connecting Capacity Auxiliary Circuit
Rigid Solid 1/2x 1 ... 2.5 mm² | Rigid Stranded 1/2x 1 ... 2.5 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid Solid 1/2x 1 ... 2.5 mm² | Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Auxiliary Circuit 10 mm | Control Circuit 10 mm | Main Circuit 10 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Auxiliary Circuit 1.2 N·m | Control Circuit 1.2 N·m | Main Circuit 1.5 N·m
Terminal Type
Screw Terminals
Product Name
Contactor Starter
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
Connecting Capacity Main Circuit UL/CSA
Rigid Solid 1/2x 16-10 AWG | Rigid Stranded 1/2x 16-10 AWG
Connecting Capacity Auxiliary Circuit UL/CSA
Rigid Solid 1/2x 18-14 AWG | Rigid Stranded 1/2x 18-14 AWG
Connecting Capacity Control Circuit UL/CSA
Rigid Solid 1/2x 18-14 AWG | Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA
Auxiliary Circuit 11 in·lb | Control Circuit 11 in·lb | Main Circuit 13 in·lb
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 60 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C
Pollution Degree
3
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
A2L Certificate – UL
UL-US A2L LZGH2 Certificate of Compliance AF09 ... AF38 3-pole contactors with screw terminals - UL 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers | UL-CA A2L LZGH2 Certificate of Compliance AF09 ... AF38 3-pole contactors with screw terminals - CSA C22.2 No. 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers
CB Certificate
CB Certificate AF09, AF12, AF16, AF09(Z)B, AF12(Z)B, AF16(Z)B 3 and 4-pole contactors, AFS09, AFS12, AFS16 safety contactors
UL Certificate
UL-US Certificate of Compliance AF(C)(S)09(R/M/N)-..(L)(S)(K)...AF(C)(S)38(R/M/N)..(K) 3-pole contactors screw, spring and push-in spring terminals; LDC4 additional coil terminal block; LF16-4, LG16-4, LF38-4 and LH38-4 connecting strips, LD38-4 additional terminal block | UL-CA Certificate of Compliance AF(C)(S)09(R/M/N)-..(L)(S)(K)...AF(C)(S)38(R/M/N)..(K) 3-pole contactors screw, spring and push-in spring terminals; LDC4 additional coil terminal block; LF16-4, LG16-4, LF38-4 and LH38-4 connecting strips, LD38-4 additional terminal block
Package Level 1 Units
box 1 piece
Package Level 1 Gross Weight
0.812 kg
Package Level 1 EAN
3471523019706
ETIM 7
EC000010 - Combination of contactors
ETIM 8
EC000010 - Combination of contactors
ETIM 9
EC000010 - Combination of contactors
eClass
V11.0 : 27371003
UNSPSC
39121529
Feature: Three-pole main contacts plus two normally open auxiliary contacts and two normally closed auxiliary contacts. Benefit: Simplifies motor control and status indication in a compact footprint, reducing panel wiring and allowing centralized control. Application: Conveyor systems, pumps, and process equipment where compact, reliable switching is required. Feature: Rated operational voltage up to 690 V and 50/60 Hz compatibility. Benefit: Supports broad industrial mains standards and fast integration with existing electrical architectures, improving system compatibility and reducing design risk. Application: Medium voltage motor drives, pumps, and line-start equipment in manufacturing environments. Feature: DC control voltage range 48–130 V and coil power optimized for low standby consumption. Benefit: Enables seamless integration with common PLC and control systems while minimizing control circuit loading. Application: Logic-level control panels and automation cabinets. Feature: DIN rail mounting TH35-15 or TH35-7.5 and screw-mount compatibility. Benefit: Fast, vibration-resistant installation with versatile mounting options, lowering assembly time and improving maintenance access. Application: Standard control panels in OEM equipment and retrofit projects. Feature: Flexible main and auxiliary circuit connections (Ferrule, insulated ferrule, rigid solid, and stranded conductors). Benefit: Broad wiring compatibility reduces termination time and ensures robust connections in harsh industrial environments. Application: Panel wiring for motors, fans, and process actuators. Feature: IP20 protection, UL/CSA and IEC 60947 compliance, 6 kV impulse withstand. Benefit: Strong protection and regulatory alignment for safer operation and easier certification. Application: Machinery, HVAC, and industrial automation panels requiring formal compliance.

Get a Quick Quote for a ABB 1SBX203301R1222

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBX203301R1222? Enquire Now

FAQs

To install, mount the Contactor Starter on a TH35 DIN rail (TH35-15 or TH35-7.5) or fasten with 2 x M4 screws as needed. Connect the main circuit conductors to the screw terminals with rated capacities for flexible or solid conductors per the guide, and wire auxiliary contacts NO/NC as required for interlocking and status feedback. Ensure coil voltage is 48-130 V DC/AC for control. Verify IP20 protection and secure tightening torques before energizing the circuit.
Key ratings include a 690 V rated main circuit and 50/60 Hz operation, with rated operational currents of up to 12 A in AC-3 applications at higher voltages and higher currents at lower voltages. The device also supports AC-1 loads up to 28 A at 690 V and provides a 6 kV impulse withstand. These specs ensure reliable switching of 3-pole motors and controlled loads in standard industrial networks.
Yes, the ABB 1SBX contactor is designed for DC control voltages in the 48-130 V range and supports AC-3 motor starting and switching. The AC-3 ratings indicate capability for frequent switching of motors and other inductive loads, with current values dependent on voltage. For example, 12 A AC-3 at higher voltages and up to 12.5 A at other voltage combinations, with suitable protective measures and cooling.
The product carries IEC/EN 60947-1 and IEC/EN 60947-4-1 standards compliance, along with UL 60335-2-40 and CSA listings. Documentation includes UL/CSA certificates, CB certificates, and REACH/RoHS declarations. These certifications support compliance for machinery safety, electrical equipment in industrial settings, and product traceability in global supply chains.
The compact DIN-rail design with integrated main and auxiliary contacts reduces wiring complexity and panel footprint, cutting installation time and labor costs. UL/CSA and IEC certifications ease regulatory approvals, while reduced panel wiring lowers fault potential and maintenance downtime. In retrofit projects, common coil voltages and standardized mounting support faster upgrades and predictable spare part availability.