ABB 1SBX203301R1422 Reversing Contactor - IEC 60947-4-1
Part Number: 1SBX203301R1422
Quick Summary
ABB 1SBX203301R1422 Reversing Contactor is a three-pole device designed to reliably reverse motors in industrial drives. This model addresses common control-panel space constraints and wiring complexity by delivering DIN-rail mounting and compact dimensions. It supports DC control within a 250–500 V range and 50/60 Hz operation, making it well-suited for low- to mid-power conveyors, hoists, and fans. The unit adheres to essential standards such as IEC/EN 60947-1 and IEC/EN 60947-4-1, with UL 60335-2-40 and CSA listings enhancing global compatibility. For procurement and maintenance teams, the combination of robust certification, clear electrical ratings, and predictable performance translates into reduced risk, easier compliance, and lower lifecycle costs across regional installations.
Product Information
Extended Description
1SBX203301R1422 ABB: AF12R-30-22-14 250-500V50/60HZ-DC Reversing Contactor
Minimum Order Quantity
1 piece
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
90 mm
Product Net Depth / Length
102.5 mm
Product Net Height
104 mm
Product Net Weight
0.722 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-4-1
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Control Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Rated Operational Current AC-1 (Ie)
(1000 V) 60 °C 28 A | (690 V) 40 °C 28 A | (690 V) 70 °C 24 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 12 A | (440 V) 60 °C 12 A | (500 V) 60 °C 12.5 A | (690 V) 60 °C 9 A | (380 / 400 V) 60 °C 12 A | (220 / 230 / 240 V) 60 °C 12 A
Rated Operational Current AC-3e (Ie)
(415 V) 60 °C 12 A | (440 V) 60 °C 12 A | (500 V) 60 °C 12.5 A | (690 V) 60 °C 9 A | (380 / 400 V) 60 °C 12 A | (220 / 230 / 240 V) 60 °C 12 A
Rated Operational Current AC-15 (Ie)
(500 V) 2 A | (690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (400 / 440 V) 3 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (48 V) 2.8 A / 134 W | (72 V) 1 A / 72 W | (110 V) 0.55 A / 60 W | (125 V) 0.55 A / 69 W | (220 V) 0.27 A / 60 W | (250 V) 0.27 A / 68 W | (400 V) 0.15 A / 60 W | (500 V) 0.13 A / 65 W | (600 V) 0.1 A / 60 W
Rated Operational Power AC-3 (Pe)
(415 V) 5.5 kW | (440 V) 5.5 kW | (500 V) 7.5 kW | (690 V) 7.5 kW | (380 / 400 V) 5.5 kW | (220 / 230 / 240 V) 3 kW
Rated Operational Power AC-3e (Pe)
(415 V) 5.5 kW | (440 V) 5.5 kW | (500 V) 7.5 kW | (690 V) 7.5 kW | (380 / 400 V) 5.5 kW | (220 / 230 / 240 V) 3 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 150 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 35 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A | for 0.1 s 140 A | for 1 s 100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 690 V | acc. to IEC 60947-5-1 690 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
6 kV
Maximum Electrical Switching Frequency
(AC-15) 1200 cycles per hour | (DC-13) 900 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 250 ... 500 V | 60 Hz 250 ... 500 V | DC Operation 250 ... 500 V
Power Loss
at 6 A per Pole 0.1 W | at Rated Operating Conditions AC-1 per Pole 1 W | at Rated Operating Conditions AC-3 per Pole 0.2 W
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 0.75 ... 6 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 4 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | Rigid Solid 1/2x 1 ... 4 mm² | Rigid Stranded 1/2x 1 ... 6 mm²
Connecting Capacity Auxiliary Circuit
Rigid Solid 1/2x 1 ... 2.5 mm² | Rigid Stranded 1/2x 1 ... 2.5 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid Solid 1/2x 1 ... 2.5 mm² | Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Auxiliary Circuit 10 mm | Control Circuit 10 mm | Main Circuit 10 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Auxiliary Circuit 1.2 N·m | Control Circuit 1.2 N·m | Main Circuit 1.5 N·m
Terminal Type
Screw Terminals
Product Name
Contactor Starter
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
Connecting Capacity Main Circuit UL/CSA
Rigid Solid 1/2x 16-10 AWG | Rigid Stranded 1/2x 16-10 AWG
Connecting Capacity Auxiliary Circuit UL/CSA
Rigid Solid 1/2x 18-14 AWG | Rigid Stranded 1/2x 18-14 AWG
Connecting Capacity Control Circuit UL/CSA
Rigid Solid 1/2x 18-14 AWG | Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA
Auxiliary Circuit 11 in·lb | Control Circuit 11 in·lb | Main Circuit 13 in·lb
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 60 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C
Pollution Degree
3
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
A2L Certificate – UL
UL-US A2L LZGH2 Certificate of Compliance AF09 ... AF38 3-pole contactors with screw terminals - UL 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers | UL-CA A2L LZGH2 Certificate of Compliance AF09 ... AF38 3-pole contactors with screw terminals - CSA C22.2 No. 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers
CB Certificate
CB Certificate AF09, AF12, AF16, AF09(Z)B, AF12(Z)B, AF16(Z)B 3 and 4-pole contactors, AFS09, AFS12, AFS16 safety contactors
UL Certificate
UL-US Certificate of Compliance AF(C)(S)09(R/M/N)-..(L)(S)(K)...AF(C)(S)38(R/M/N)..(K) 3-pole contactors screw, spring and push-in spring terminals; LDC4 additional coil terminal block; LF16-4, LG16-4, LF38-4 and LH38-4 connecting strips, LD38-4 additional terminal block | UL-CA Certificate of Compliance AF(C)(S)09(R/M/N)-..(L)(S)(K)...AF(C)(S)38(R/M/N)..(K) 3-pole contactors screw, spring and push-in spring terminals; LDC4 additional coil terminal block; LF16-4, LG16-4, LF38-4 and LH38-4 connecting strips, LD38-4 additional terminal block
Package Level 1 Units
box 1 piece
Package Level 1 Gross Weight
0.872 kg
Package Level 1 EAN
3471523019720
ETIM 7
EC000010 - Combination of contactors
ETIM 8
EC000010 - Combination of contactors
ETIM 9
EC000010 - Combination of contactors
eClass
V11.0 : 27371003
UNSPSC
39121529
Feature: Three main NO contacts with 3 poles and two NO auxiliary contacts of the unit. Business Impact: Expands switching capability for motor loads while enabling compact control schemes, reducing panel space and wiring complexity. Application: Reversing drives in conveyors or hoists where reliable motor reversal is required with minimal footprint. Feature: DC control circuit rated 250 ... 500 V and 50/60 Hz control. Business Impact: Simplifies integration with existing DC control logic and offers flexible drive coordination, decreasing integration time. Application: Control of reverse motion in automated material handling systems. Feature: Rated insulation voltage 690 V and impedance with 6 kV impulse withstand. Business Impact: Ensures safe operation in higher voltage environments and improves surge resilience, lowering protective relays burden. Application: 690 V industrial motor control panels with demanding transient conditions. Feature: Mounting on DIN rails TH35-15 and TH35-7.5; Screw terminal wiring. Business Impact: Eases installation and serviceability, enabling faster panel assembly and future maintenance. Application: Modern control cabinets requiring modular, serviceable components. Feature: Connection capacities for Main, Auxiliary, and Control circuits with specified wire ranges. Business Impact: Facilitates versatile wiring configurations and reliable terminations, reducing contact resistance and heating under load. Application: Clean, compliant terminations for power and control circuits in automation lines. Feature: Tightening torque specifications and IP20 protection. Business Impact: Predictable installation quality and adequate protection in standard indoor environments, minimizing damage risk and maintenance. Application: Factory floor enclosures and control panels with moderate exposure. Feature: Compliance suite includes IEC/EN, UL, CSA, CB certificates, RoHS, REACH, and WEEE. Business Impact: Simplifies cross-border procurement, ensures regulatory alignment, and reduces compliance overhead. Application: Global deployment of automation equipment with strict regulatory requirements.
Get a Quick Quote for a ABB 1SBX203301R1422
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SBX203301R1422?
Enquire Now
FAQs
This device is designed for DIN rail mounting (TH35-15 or TH35-7.5). Use screw terminals for Main, Auxiliary, and Control circuits. Main circuit terminations accept flexible ferrule 1/2x 0.75 … 6 mm² and rigid solid 1/2x 1 … 4 mm², while auxiliary and control circuits support smaller gauges. Ensure proper stripping (10 mm) and tighten to 1.2–1.5 N·m as specified per circuit. Verify 690 V insulation and 6 kV impulse withstand ratings are not exceeded by the install location.
The contactor supports AC-3 operation with rated currents up to 12 A at 415–440 V and 12.5 A at 500 V, with 9 A at 690 V. For AC-1, currents are up to 28 A at 690 V depending on ambient temperature. The DC control circuit operates in the 250–500 V range, with 50/60 Hz control and main circuit ratings compatible with typical DC start-stop logic in automation panels.
Yes. The part holds UL/CSA listings (UL-US A2L LZGH2 and CSA 60335-2-40 related approvals) and a CB Certificate for cross-border safety verification. This means you can streamline global procurement, simplify supplier qualification, and maintain consistent compliance across installations in North America and other regions, reducing design redrafts and audit findings.
Ideal for motor reversal tasks in conveyors, hoists, fans, and other drive systems where compact panels are essential. The 3P design with 3 main NO contacts and 2 auxiliary contacts supports reversing logic while maintaining reliable interlock capabilities. Use cases include small to mid-size automated lines with 690 V insulation and demanding surge resilience thanks to 6 kV impulse withstand.
The device uses screw terminals and DIN-rail mounting designed for easy replacement and reduced downtime. With robust TÜV/UL/CSA certifications and high reliability under typical ambient conditions, you can expect lower maintenance costs and longer service life. The compact footprint and straightforward wiring reduce upfront installation time, lowering total cost of ownership for motor-reversal applications.