ABB 1SBX203301R2122 Reversing Contactor - IEC/UL 60947-4-1
Part Number: 1SBX203301R2122
Quick Summary
ABB 1SBX203301R2122 Reversing Contactor is designed to reverse motor direction in compact starter panels, delivering reliable three-pole control. Engineers often struggle with space constraints, wiring complexity, and matching coil voltages across control circuits. This device meets IEC/EN 60947-1 and 60947-4-1, UL 60335-2-40 (LZGH2 A2L), and CSA requirements, ensuring safety, compatibility, and predictable performance. By combining DIN-rail mounting with versatile coil voltages and robust contacts, it reduces installation time and simplifies panel design, helping maintenance teams improve uptime. For procurement teams, standardized ABB components translate into lower total cost of ownership and easier spare parts management across multi-site electrical installations.
Product Information
Extended Description
1SBX203301R2122 ABB: AF12ZR-30-22-21 24-60V50/60HZ 20-60VDC Reversing Contactor
Minimum Order Quantity
1 piece
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
90 mm
Product Net Depth / Length
102.5 mm
Product Net Height
104 mm
Product Net Weight
0.742 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-4-1
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Control Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Rated Operational Current AC-1 (Ie)
(1000 V) 60 °C 28 A | (690 V) 40 °C 28 A | (690 V) 70 °C 24 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 12 A | (440 V) 60 °C 12 A | (500 V) 60 °C 12.5 A | (690 V) 60 °C 9 A | (380 / 400 V) 60 °C 12 A | (220 / 230 / 240 V) 60 °C 12 A
Rated Operational Current AC-3e (Ie)
(415 V) 60 °C 12 A | (440 V) 60 °C 12 A | (500 V) 60 °C 12.5 A | (690 V) 60 °C 9 A | (380 / 400 V) 60 °C 12 A | (220 / 230 / 240 V) 60 °C 12 A
Rated Operational Current AC-15 (Ie)
(500 V) 2 A | (690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (400 / 440 V) 3 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (48 V) 2.8 A / 134 W | (72 V) 1 A / 72 W | (110 V) 0.55 A / 60 W | (125 V) 0.55 A / 69 W | (220 V) 0.27 A / 60 W | (250 V) 0.27 A / 68 W | (400 V) 0.15 A / 60 W | (500 V) 0.13 A / 65 W | (600 V) 0.1 A / 60 W
Rated Operational Power AC-3 (Pe)
(415 V) 5.5 kW | (440 V) 5.5 kW | (500 V) 7.5 kW | (690 V) 7.5 kW | (380 / 400 V) 5.5 kW | (220 / 230 / 240 V) 3 kW
Rated Operational Power AC-3e (Pe)
(415 V) 5.5 kW | (440 V) 5.5 kW | (500 V) 7.5 kW | (690 V) 7.5 kW | (380 / 400 V) 5.5 kW | (220 / 230 / 240 V) 3 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 150 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 35 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A | for 0.1 s 140 A | for 1 s 100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 690 V | acc. to IEC 60947-5-1 690 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
6 kV
Maximum Electrical Switching Frequency
(AC-15) 1200 cycles per hour | (DC-13) 900 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 24 ... 60 V | 60 Hz 24 ... 60 V | DC Operation 20 ... 60 V
Power Loss
at 6 A per Pole 0.1 W | at Rated Operating Conditions AC-1 per Pole 1 W | at Rated Operating Conditions AC-3 per Pole 0.2 W
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 0.75 ... 6 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 4 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | Rigid Solid 1/2x 1 ... 4 mm² | Rigid Stranded 1/2x 1 ... 6 mm²
Connecting Capacity Auxiliary Circuit
Rigid Solid 1/2x 1 ... 2.5 mm² | Rigid Stranded 1/2x 1 ... 2.5 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid Solid 1/2x 1 ... 2.5 mm² | Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Auxiliary Circuit 10 mm | Control Circuit 10 mm | Main Circuit 10 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Auxiliary Circuit 1.2 N·m | Control Circuit 1.2 N·m | Main Circuit 1.5 N·m
Terminal Type
Screw Terminals
Product Name
Contactor Starter
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
Connecting Capacity Main Circuit UL/CSA
Rigid Solid 1/2x 16-10 AWG | Rigid Stranded 1/2x 16-10 AWG
Connecting Capacity Auxiliary Circuit UL/CSA
Rigid Solid 1/2x 18-14 AWG | Rigid Stranded 1/2x 18-14 AWG
Connecting Capacity Control Circuit UL/CSA
Rigid Solid 1/2x 18-14 AWG | Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA
Auxiliary Circuit 11 in·lb | Control Circuit 11 in·lb | Main Circuit 13 in·lb
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 60 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C
Pollution Degree
3
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
A2L Certificate – UL
UL-US A2L LZGH2 Certificate of Compliance AF09 ... AF38 3-pole contactors with screw terminals - UL 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers | UL-CA A2L LZGH2 Certificate of Compliance AF09 ... AF38 3-pole contactors with screw terminals - CSA C22.2 No. 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers
CB Certificate
CB Certificate AF09, AF12, AF16, AF09(Z)B, AF12(Z)B, AF16(Z)B 3 and 4-pole contactors, AFS09, AFS12, AFS16 safety contactors
UL Certificate
UL-US Certificate of Compliance AF(C)(S)09(R/M/N)-..(L)(S)(K)...AF(C)(S)38(R/M/N)..(K) 3-pole contactors screw, spring and push-in spring terminals; LDC4 additional coil terminal block; LF16-4, LG16-4, LF38-4 and LH38-4 connecting strips, LD38-4 additional terminal block | UL-CA Certificate of Compliance AF(C)(S)09(R/M/N)-..(L)(S)(K)...AF(C)(S)38(R/M/N)..(K) 3-pole contactors screw, spring and push-in spring terminals; LDC4 additional coil terminal block; LF16-4, LG16-4, LF38-4 and LH38-4 connecting strips, LD38-4 additional terminal block
Package Level 1 Units
box 1 piece
Package Level 1 Gross Weight
0.892 kg
Package Level 1 EAN
3471523019737
ETIM 7
EC000010 - Combination of contactors
ETIM 8
EC000010 - Combination of contactors
ETIM 9
EC000010 - Combination of contactors
eClass
V11.0 : 27371003
UNSPSC
39121529
Feature: Three-pole design with three main normally open contacts and two auxiliary normally open/closed contacts enables reliable motor reversal in compact footprints. Business Impact: Simplifies control logic and reduces panel depth while supporting standard motor load switching. Application: Suitable for small to mid-size conveyor, pump, and fan drives where space is at a premium. Feature: Coil voltage range 24–60 V (AC) and 20–60 V (DC) provides flexible integration with existing control systems. Business Impact: Enables seamless PLC or relay network interfacing with minimal power supply changes. Application: Industrial automation panels using mixed-voltage control schemes. Feature: DIN rail mounting TH35-15 (and TH35-7.5) plus screw-terminal wiring simplifies installation and serviceability. Business Impact: Faster commissioning, easier field maintenance, reduced commissioning errors. Application: Factory automation enclosures and control cabinets. Feature: Rated voltage up to 690 V and multiple current ratings (AC-1, AC-3, DC-13) offer broad compatibility with standard motor loads. Business Impact: Supports scalable motor control while maintaining safe, predictable switching performance. Application: Pumps, conveyors, fans in harsh plant environments. Feature: Power loss and thermal performance (0.1 W per pole at 6 A; 0.2 W per pole in AC-3) provide energy efficiency and cooler operation. Business Impact: Lower energy waste in continuous-duty applications and extended component life. Application: Continuous process lines with frequent switching. Feature: Comprehensive certifications (IEC/EN 60947-1, 60947-4-1; UL 60335-2-40; CSA) provide regulatory confidence. Business Impact: Accelerates approvals, reduces risk in multi-region deployments. Application: Global manufacturing sites with strict safety compliance. Feature: Mechanical and terminal robustness (screw terminals, 2 x M4 mounting screws) supports reliable field wiring. Business Impact: Durable connections under vibration and temperature swings. Application: Wind-down and restart cycles in demanding environments.
Get a Quick Quote for a ABB 1SBX203301R2122
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SBX203301R2122?
Enquire Now
FAQs
Mounting is straightforward with DIN rail TH35-15 (and TH35-7.5) supported, plus two M4 screws for panel fixation. This enables quick installation, consistent spacing, and reliable vibration resistance in industrial cabinets. Ensure the DIN rail run is clean and that the unit sits securely to maintain terminal integrity during operation.
For AC-3 operation, the device handles up to 12 A at common voltages (including 415–690 V variants) with appropriate derating at higher voltages or ambient temperatures. DC-13 ratings show reduced current at higher DC voltages (for example, 24 V up to 6 A; 600 V down to 0.1 A). These ratings support motor starting and switching suitable for small to mid-size loads.
Yes. The contactor coil supports 24–60 V across AC (50/60 Hz) and DC operation ranges, providing flexibility to interface with most PLCs, relays, and control circuits without extra power supplies. This reduces wiring complexity and potential control voltage mismatches in automation panels.
The device conforms to IEC/EN 60947-1 and 60947-4-1, with UL 60335-2-40 (LZGH2 A2L) and CSA equivalents, ensuring compliance for safety and appliance standards across multiple regions. These certifications streamline cross-border procurement and support regulatory approvals for equipment in varied facilities.
Product net width is 90 mm, depth 102.5 mm, and height 104 mm, with a net weight of 0.742 kg. Package weight is 0.892 kg. These dimensions help calculate panel space, clearance for wiring, and ensure proper fit in compact control housings.