ABB AF30R-30-22-11 Reversing Contactor - IEC/EN 60947-4-1 Certified

Part Number: 1SBX206311R1122
Manufacturer
ABB
Part number
1SBX206311R1122

Quick Summary

ABB AF30R-30-22-11 Reversing Contactor is a compact motor switch designed for reversing drives in industrial applications. Engineers often face procurement delays and mismatched coil voltages that lead to extended downtime; this device provides a unified solution with flexible control options. This contactor adheres to IEC/EN 60947-1 and IEC/EN 60947-4-1, with UL 60335-2-40 and CSA 60947-4-1 family certifications, enabling safe global implementation. By combining 24–60 V control with 690 V main circuit ratings and a 3P configuration, it streamlines panel design, reduces footprint, and supports scalable automation in assembly lines, conveyors, and pump stations.

Product Information

Extended Description

1SBX206311R1122 ABB: AF30R-30-22-11 24-60V50/60HZ 20-60VDC Reversing Contactor
Minimum Order Quantity
1 piece
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
90 mm
Product Net Depth / Length
119.5 mm
Product Net Height
112.5 mm
Product Net Weight
0.814 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-4-1
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Control Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Rated Operational Current AC-1 (Ie)
(1000 V) 60 °C 42 A | (690 V) 40 °C 50 A | (690 V) 70 °C 37 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 32 A | (440 V) 60 °C 32 A | (500 V) 60 °C 28 A | (690 V) 60 °C 21 A | (380 / 400 V) 60 °C 32 A | (220 / 230 / 240 V) 60 °C 33 A
Rated Operational Current AC-3e (Ie)
(415 V) 60 °C 32 A | (440 V) 60 °C 32 A | (500 V) 60 °C 28 A | (690 V) 60 °C 21 A | (380 / 400 V) 60 °C 32 A | (220 / 230 / 240 V) 60 °C 33 A
Rated Operational Current AC-15 (Ie)
(500 V) 2 A | (690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (400 / 440 V) 3 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (48 V) 2.8 A / 134 W | (72 V) 1 A / 72 W | (110 V) 0.55 A / 60 W | (125 V) 0.55 A / 69 W | (220 V) 0.27 A / 60 W | (250 V) 0.27 A / 68 W | (400 V) 0.15 A / 60 W | (500 V) 0.13 A / 65 W | (600 V) 0.1 A / 60 W
Rated Operational Power AC-3 (Pe)
(415 V) 15 kW | (440 V) 18.5 kW | (500 V) 18.5 kW | (690 V) 18.5 kW | (380 / 400 V) 15 kW | (220 / 230 / 240 V) 9 kW
Rated Operational Power AC-3e (Pe)
(415 V) 15 kW | (440 V) 18.5 kW | (500 V) 18.5 kW | (690 V) 18.5 kW | (380 / 400 V) 15 kW | (220 / 230 / 240 V) 9 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 350 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 50 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 700 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A | for 0.1 s 140 A | for 1 s 100 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 690 V | acc. to IEC 60947-5-1 690 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
6 kV
Maximum Electrical Switching Frequency
(AC-15) 1200 cycles per hour | (DC-13) 900 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 24 ... 60 V | 60 Hz 24 ... 60 V | DC Operation 20 ... 60 V
Power Loss
at 6 A per Pole 0.1 W | at Rated Operating Conditions AC-1 per Pole 2.4 W | at Rated Operating Conditions AC-3 per Pole 0.9 W
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 1.5 ... 10 mm² | Flexible with Insulated Ferrule 1x 1.5 ... 10 mm² | Flexible with Insulated Ferrule 2x 1.5 ... 4 mm² | Rigid Solid 1/2x 2.5 ... 4 mm² | Rigid Stranded 1/2x 2.5 ... 10 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid Solid 1/2x 1 ... 2.5 mm² | Rigid Stranded 1/2x 1 ... 2.5 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid Solid 1/2x 1 ... 2.5 mm² | Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Auxiliary Circuit 10 mm | Control Circuit 10 mm | Main Circuit 14 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Auxiliary Circuit 1.2 N·m | Control Circuit 1.2 N·m | Main Circuit 2.5 N·m
Terminal Type
Screw Terminals
Product Name
Contactor Starter
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
Connecting Capacity Main Circuit UL/CSA
Rigid Solid 1/2x 14-10 AWG | Rigid Stranded 1/2x 14-8 AWG
Connecting Capacity Auxiliary Circuit UL/CSA
Rigid Solid 1/2x 18-14 AWG | Rigid Stranded 1/2x 18-14 AWG
Connecting Capacity Control Circuit UL/CSA
Rigid Solid 1/2x 18-14 AWG | Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA
Auxiliary Circuit 11 in·lb | Control Circuit 11 in·lb | Main Circuit 22 in·lb
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 60 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C
Pollution Degree
3
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
A2L Certificate – UL
UL-US A2L LZGH2 Certificate of Compliance AF09 ... AF38 3-pole contactors with screw terminals - UL 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers | UL-CA A2L LZGH2 Certificate of Compliance AF09 ... AF38 3-pole contactors with screw terminals - CSA C22.2 No. 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers
CB Certificate
CB Certificate AF26(Z)(B), AF30(Z)(B), AF(Z)(B)38 3-pole contactors, AFS26, AFS30, AFS38 safety contactors
UL Certificate
UL-US Certificate of Compliance AF(C)(S)09(R/M/N)-..(L)(S)(K)...AF(C)(S)38(R/M/N)..(K) 3-pole contactors screw, spring and push-in spring terminals; LDC4 additional coil terminal block; LF16-4, LG16-4, LF38-4 and LH38-4 connecting strips, LD38-4 additional terminal block | UL-CA Certificate of Compliance AF(C)(S)09(R/M/N)-..(L)(S)(K)...AF(C)(S)38(R/M/N)..(K) 3-pole contactors screw, spring and push-in spring terminals; LDC4 additional coil terminal block; LF16-4, LG16-4, LF38-4 and LH38-4 connecting strips, LD38-4 additional terminal block
Package Level 1 Units
box 1 piece
Package Level 1 Gross Weight
0.964 kg
Package Level 1 EAN
3471523019843
ETIM 7
EC000010 - Combination of contactors
ETIM 8
EC000010 - Combination of contactors
ETIM 9
EC000010 - Combination of contactors
eClass
V11.0 : 27371003
UNSPSC
39121529
Feature 1: 3P main NO contacts with 2 NO and 2 NC auxiliary contacts. Business Impact: Increases control flexibility and feedback options, enabling interlocking and sequencing without additional relays. Application: Conveyor lines and press stations where precise motor start/stop and status monitoring are essential. Feature 2: Coil voltage range 24–60 V (AC/DC). Business Impact: Compatible with common PLC outputs and low-voltage control schemes, reducing wiring complexity and sourcing costs. Application: Panel-mounted drives and automation cabinets in rolling stock, packaging, and material handling. Feature 3: Rated main circuit voltage up to 690 V and rated operational currents (AC-3) up to 32 A, with AC-1/AC-3e variants. Business Impact: Supports high-efficiency motor control for pumps, fans, and conveyors while maintaining safe thermal performance. Application: Industrial fans, pumps, and small to mid-size motors in manufacturing lines. Feature 4: DIN rail mounting (TH35-15 or TH35-7.5) and compatible screw-terminal assembly. Business Impact: Fast, secure installation with reduced panel depth and improved serviceability. Application: New builds and retrofit projects in control panels. Feature 5: Low power loss per pole (0.1 W) and robust insulation (U_i 690 V). Business Impact: Reduces heat generation in cabinets and extends component life, lowering energy and maintenance costs. Application: Continuous-duty automation environments with tight thermal margins. Feature 6: IP20 protection and solid wiring capacity for main and auxiliary circuits. Business Impact: Enhanced protection against dust ingress in indoor panels and reliable termination for copper conductors up to 10 mm². Application: Panel installations in commercial facilities and discrete manufacturing lines. Feature 7: Compliance bundle including IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 and CSA standards. Business Impact: Facilitates global procurement and reduces regulatory risk across multiple regions. Application: Multinational production sites and OEM equipment. Feature 8: Versatile mounting and terminal configuration with specified torque values (Main 2.5 N·m, Auxiliary 1.2 N·m, UL 11 in-lb). Business Impact: Ensures repeatable, secure connections and predictable installation torque, lowering the likelihood of terminal loosening in service. Application: Control panels with frequent temperature cycling and vibration.

Get a Quick Quote for a ABB 1SBX206311R1122

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBX206311R1122? Enquire Now

FAQs

This device is designed for DIN rail mounting (TH35-15 or TH35-7.5) and uses screw terminals. For retrofit projects, ensure panel depth accommodates 119.5 mm length and 90 mm width, and verify torque specifications: 2.5 N·m on the main circuit, 1.2 N·m on auxiliary/control circuits. The coil voltage range 24–60 V supports common PLC outputs, simplifying integration.
Key specs include three main NO contacts, two NO and two NC auxiliary contacts, 3P poles, coil voltage 24–60 V (AC/DC), main circuit rating up to 690 V, and rated currents AC-3 up to 32 A. It supports 50/60 Hz operation, 6 kV impulse withstand, and a maximum switching frequency of 1200 cycles per hour (AC-15).
Yes. With AC-3 and DC-13 ratings and a compact 3P architecture, it handles frequent starting/stopping, while low per-pole power loss minimizes heat buildup. For conveyor and pump applications, its 24–60 V control and 690 V insulation enable reliable operation across fluctuating loads and voltages.
The AF30R-30-22-11 complies with IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40, CSA C22.2, and related UL/CSA 60947-4-1 listings. These certifications support global regulatory acceptance and help streamline cross-border procurement for OEMs and integrators.
Low power loss (0.1 W per pole) reduces heat and energy use, contributing to longer service life and lower operating costs. The device’s robust insulation, IP20 rating, and standard torque specs simplify maintenance, leading to lower downtime and a favorable return on investment in continuous-operation environments.