ABB 1SBX207311R1422 Contactor Starter - UL/CSA LZGH2 A2L
Part Number: 1SBX207311R1422
Quick Summary
ABB 1SBX207311R1422 Contactor Starter is a compact, 3-pole device for motor control in industrial panels. It addresses wiring density and reliability challenges in high-voltage control circuits by using screw terminals and a DIN-rail compatible footprint. Manufactured to IEC/EN 60947-1 and IEC/EN 60947-4-1, with UL/CSA LZGH2 A2L certificates, it satisfies global safety and performance standards. Designed for robust control of AC- and DC-driven equipment, it offers 690 V ratings, 50/60 Hz operation, and proven compatibility with ABB control systems. This combination delivers dependable automation performance, reduced maintenance, and scalable panel integration for modern manufacturing environments.
Product Information
Extended Description
1SBX207311R1422 ABB: AF38R-30-22-14 250-500V50/60HZ-DC Reversing Contactor
Minimum Order Quantity
1 piece
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
90 mm
Product Net Depth / Length
119.5 mm
Product Net Height
112.5 mm
Product Net Weight
0.848 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-4-1
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Control Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Rated Operational Current AC-1 (Ie)
(1000 V) 60 °C 42 A | (690 V) 40 °C 50 A | (690 V) 70 °C 37 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 38 A | (440 V) 60 °C 38 A | (500 V) 60 °C 33 A | (690 V) 60 °C 24 A | (380 / 400 V) 60 °C 38 A | (220 / 230 / 240 V) 60 °C 40 A
Rated Operational Current AC-3e (Ie)
(415 V) 60 °C 38 A | (440 V) 60 °C 38 A | (500 V) 60 °C 33 A | (690 V) 60 °C 24 A | (380 / 400 V) 60 °C 38 A | (220 / 230 / 240 V) 60 °C 40 A
Rated Operational Current AC-15 (Ie)
(500 V) 2 A | (690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (400 / 440 V) 3 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (48 V) 2.8 A / 134 W | (72 V) 1 A / 72 W | (110 V) 0.55 A / 60 W | (125 V) 0.55 A / 69 W | (220 V) 0.27 A / 60 W | (250 V) 0.27 A / 68 W | (400 V) 0.15 A / 60 W | (500 V) 0.13 A / 65 W | (600 V) 0.1 A / 60 W
Rated Operational Power AC-3 (Pe)
(415 V) 18.5 kW | (440 V) 22 kW | (500 V) 22 kW | (690 V) 22 kW | (380 / 400 V) 18.5 kW | (220 / 230 / 240 V) 11 kW
Rated Operational Power AC-3e (Pe)
(415 V) 18.5 kW | (440 V) 22 kW | (500 V) 22 kW | (690 V) 22 kW | (380 / 400 V) 18.5 kW | (220 / 230 / 240 V) 11 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 350 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 50 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 700 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A | for 0.1 s 140 A | for 1 s 100 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 690 V | acc. to IEC 60947-5-1 690 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
6 kV
Maximum Electrical Switching Frequency
(AC-15) 1200 cycles per hour | (DC-13) 900 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 250 ... 500 V | 60 Hz 250 ... 500 V | DC Operation 250 ... 500 V
Power Loss
at 6 A per Pole 0.1 W | at Rated Operating Conditions AC-1 per Pole 2.4 W | at Rated Operating Conditions AC-3 per Pole 1.3 W
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 1.5 ... 10 mm² | Flexible with Insulated Ferrule 1x 1.5 ... 10 mm² | Flexible with Insulated Ferrule 2x 1.5 ... 4 mm² | Rigid Solid 1/2x 2.5 ... 4 mm² | Rigid Stranded 1/2x 2.5 ... 10 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid Solid 1/2x 1 ... 2.5 mm² | Rigid Stranded 1/2x 1 ... 2.5 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid Solid 1/2x 1 ... 2.5 mm² | Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Auxiliary Circuit 10 mm | Control Circuit 10 mm | Main Circuit 14 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Auxiliary Circuit 1.2 N·m | Control Circuit 1.2 N·m | Main Circuit 2.5 N·m
Terminal Type
Screw Terminals
Product Name
Contactor Starter
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
Connecting Capacity Main Circuit UL/CSA
Rigid Solid 1/2x 14-10 AWG | Rigid Stranded 1/2x 14-8 AWG
Connecting Capacity Auxiliary Circuit UL/CSA
Rigid Solid 1/2x 18-14 AWG | Rigid Stranded 1/2x 18-14 AWG
Connecting Capacity Control Circuit UL/CSA
Rigid Solid 1/2x 18-14 AWG | Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA
Auxiliary Circuit 11 in·lb | Control Circuit 11 in·lb | Main Circuit 22 in·lb
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 60 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C
Pollution Degree
3
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
A2L Certificate – UL
UL-US A2L LZGH2 Certificate of Compliance AF09 ... AF38 3-pole contactors with screw terminals - UL 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers | UL-CA A2L LZGH2 Certificate of Compliance AF09 ... AF38 3-pole contactors with screw terminals - CSA C22.2 No. 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers
CB Certificate
CB Certificate AF26(Z)(B), AF30(Z)(B), AF(Z)(B)38 3-pole contactors, AFS26, AFS30, AFS38 safety contactors
UL Certificate
UL-US Certificate of Compliance AF(C)(S)09(R/M/N)-..(L)(S)(K)...AF(C)(S)38(R/M/N)..(K) 3-pole contactors screw, spring and push-in spring terminals; LDC4 additional coil terminal block; LF16-4, LG16-4, LF38-4 and LH38-4 connecting strips, LD38-4 additional terminal block | UL-CA Certificate of Compliance AF(C)(S)09(R/M/N)-..(L)(S)(K)...AF(C)(S)38(R/M/N)..(K) 3-pole contactors screw, spring and push-in spring terminals; LDC4 additional coil terminal block; LF16-4, LG16-4, LF38-4 and LH38-4 connecting strips, LD38-4 additional terminal block
Package Level 1 Units
box 1 piece
Package Level 1 Gross Weight
0.998 kg
Package Level 1 EAN
3471523019928
ETIM 7
EC000010 - Combination of contactors
ETIM 8
EC000010 - Combination of contactors
ETIM 9
EC000010 - Combination of contactors
eClass
V11.0 : 27371003
UNSPSC
39121529
Feature → Business Impact → Application: The contactor offers 3 main NO contacts with 2 auxiliary NO and 2 NC, enabling reliable motor switching with clear fault separation, which reduces downtime and simplifies maintenance in conveyor and pump drives. Application: 3P motor control in automation panels where space is at a premium and clear separation of control and power circuits is required. Feature → Business Impact → Application: Rated operational voltage of auxiliary and main circuits at 690 V and 50/60 Hz ensures compatibility with common European and global power networks, supporting cross-site deployments and standardized spare parts. Application: High-voltage motor starters for food processing lines and process automation where standardization reduces spare parts stock. Feature → Business Impact → Application: DIN-rail mounting (TH35-15 or TH35-7.5) and screw-terminal connections enable quick, secure installations and simplified field servicing. Application: Panel builders seeking fast commissioning and reliable terminal retention in tight control cabinets. Feature → Business Impact → Application: 3P 690 V AC-3/AC-3e ratings and 24–38 A practical current support for medium-size motors, delivering efficient control with predictable thermal behavior. Application: HVAC fans, pumps, and compound drives where predictable performance under continuous duty is essential. Feature → Business Impact → Application: Tightening torques (Main 2.5 N·m; Auxiliary/Control 1.2 N·m) and clear wire-stripping guidance reduce installation errors and improve long-term reliability. Application: Prevents loose connections in high-vibration environments. Feature → Business Impact → Application: IP20 protection and robust UL/CSA certification provide compliance confidence for installation in industrial enclosures and consumer-adjacent equipment. Application: Industrial automation panels subject to strict safety and environmental requirements. Feature → Business Impact → Application: Reversing-contactor capability with DC control and a 3P configuration supports bidirectional motor control in material handling and production lines. Application: Reversing drives in conveyors and mixer systems where bi-directional operation is required and space is at a premium. Feature → Business Impact → Application: Comprehensive datasheet availability including 2D/3D CAD files simplifies design integration and reduces engineering cycles. Application: Engineers can accelerate BOM creation and CAD assembly processes, shortening time-to-production.
Get a Quick Quote for a ABB 1SBX207311R1422
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SBX207311R1422?
Enquire Now
FAQs
This unit supports TH35 mounting rails (TH35-15 or TH35-7.5) and requires 2 x M4 screws for panel fixation. Use the DIN rail clip provided and ensure the device is seated firmly to avoid micro-movements in high-vibration environments. Proper alignment with adjacent devices minimizes wiring congestion and improves serviceability.
Key ratings include main and auxiliary circuits rated up to 690 V AC/DC, 50/60 Hz operation, 3 main NO contacts, 2 auxiliary NO, and 2 auxiliary NC contacts. AC-3e ratings reach up to 38 A at typical voltages, with power switching up to 22 kW at 415–690 V. The coil control voltage is 250–500 V across 50/60 Hz, enabling versatile integration with high-voltage controls.
Yes. The AF38R-based family includes DC reversing functionality, and the unit provides a 3P configuration with corresponding auxiliary contacts to support control logic for bidirectional motor drives. It is ideal for conveyors, packaging lines, and material handling equipment needing reliable forward/reverse operation.
The product complies with IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 including LZGH2 A2L certification, and CSA equivalents. These certifications ensure safety, electrical reliability, and suitability for global commercial and industrial installations.
Tightening torque is 2.5 N·m for the main circuit terminals and 1.2 N·m for auxiliary and control circuit terminals. Wire connections use screw terminals with stripping lengths of 14 mm for main conductors and 10 mm for auxiliary and control conductors. Following these specs helps maintain secure connections and minimize heat buildup.