ABB 1SBX208321R1222 Reversing Contactor enables bidirectional motor control in compact starters for conveyors and packaging lines. Operators face downtime from wiring complexity, control-voltage compatibility, and installing across evolving voltage environments, which can bottleneck project timelines and inflate costs. This device meets IEC/EN 60947-4-1, IEC/EN 60947-1, UL 60335-2-40, and CSA certifications, delivering robust safety, interoperability, and regulatory compliance across global sites. With DIN-rail mounting compatibility and a three-pole main circuit plus two auxiliary contacts, it supports scalable control architectures, easy panel integration, and reduced commissioning time. By combining solid electrical ratings with compact dimensions, it helps improve energy efficiency, reliability, and maintenance predictability for OEMs and end users alike.
Product Information
Extended Description
1SBX208321R1222 ABB: AF40R-30-22-12 48-130V50/60HZ-DC Reversing Contactor
Minimum Order Quantity
1 piece
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
110 mm
Product Net Depth / Length
144 mm
Product Net Height
151 mm
Product Net Weight
2.384 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Control Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Rated Operational Current AC-1 (Ie)
(1000 V) 60 °C 60 A | (690 V) 40 °C 70 A | (690 V) 70 °C 50 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 40 A | (440 V) 60 °C 40 A | (500 V) 60 °C 35 A | (690 V) 60 °C 25 A | (380 / 400 V) 60 °C 40 A | (220 / 230 / 240 V) 60 °C 40 A
Rated Operational Current AC-3e (Ie)
(415 V) 60 °C 40 A | (440 V) 60 °C 40 A | (500 V) 60 °C 35 A | (690 V) 60 °C 25 A | (380 / 400 V) 60 °C 40 A | (220 / 230 / 240 V) 60 °C 40 A
Rated Operational Current AC-15 (Ie)
(500 V) 2 A | (690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (400 / 440 V) 3 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (48 V) 2.8 A / 134 W | (72 V) 1 A / 72 W | (110 V) 0.55 A / 60 W | (125 V) 0.55 A / 69 W | (220 V) 0.27 A / 60 W | (250 V) 0.27 A / 68 W | (400 V) 0.15 A / 60 W | (500 V) 0.13 A / 65 W | (600 V) 0.1 A / 60 W
Rated Operational Power AC-3 (Pe)
(415 V) 22 kW | (440 V) 22 kW | (500 V) 22 kW | (690 V) 22 kW | (380 / 400 V) 18.5 kW | (220 / 230 / 240 V) 11 kW
Rated Operational Power AC-3e (Pe)
(415 V) 22 kW | (440 V) 22 kW | (500 V) 22 kW | (690 V) 22 kW | (380 / 400 V) 18.5 kW | (220 / 230 / 240 V) 11 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A | for 0.1 s 140 A | for 1 s 100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 690 V | acc. to IEC 60947-5-1 690 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
6 kV
Maximum Electrical Switching Frequency
(AC-15) 1200 cycles per hour | (DC-13) 900 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 48 ... 130 V | 60 Hz 48 ... 130 V | DC Operation 48 ... 130 V
Power Loss
at 6 A per Pole 0.1 W | at Rated Operating Conditions AC-1 per Pole 3 W | at Rated Operating Conditions AC-3 per Pole 1 W
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 or 2 x M6 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 4 ... 35 mm² | Flexible with Insulated Ferrule 1/2x 4 ... 35 mm² | Rigid Stranded 1/2x 6 ... 35 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid Solid 1/2x 1 ... 2.5 mm² | Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Auxiliary Circuit 10 mm | Control Circuit 10 mm | Main Circuit 16 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Tightening Torque
Auxiliary Circuit 1.2 N·m | Control Circuit 1.2 N·m | Main Circuit 4 N·m
Terminal Type
Screw Terminals
Product Name
Contactor Starter
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
Connecting Capacity Main Circuit UL/CSA
Rigid Stranded 1/2x 10-2 AWG
Connecting Capacity Control Circuit UL/CSA
Rigid Solid 1/2x 18-14 AWG | Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA
Auxiliary Circuit 11 in·lb | Control Circuit 11 in·lb | Main Circuit 35 in·lb
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C
Pollution Degree
3
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
A2L Certificate – UL
UL-US Certificate of Compliance AF40 ... AF96 3-pole contactors - UL 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers | UL-CA Certificate of Compliance AF40 ... AF96 3-pole contactors - CSA C22.2 No. 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers
CB Certificate
CB Certificate AF(S)40(B), (S)AF52(B), AF(S)65(B) 3 and 4-pole contactors
CCC Certificate
CQC Certificate, Contactor, AF*40-30-**-**, AF40-40-**-**, AF40-22-**-**, AF*52-30-**-**, AF52-40-**-**,AF*65-30-**-**, Made in France
UL Certificate
UL-US-L312527-1141-10303102-9 | UL-CA-L312527-4141-10303102-9
Package Level 1 Units
box 1 piece
Package Level 1 Gross Weight
2.584 kg
Package Level 1 EAN
3471523019959
ETIM 7
EC000010 - Combination of contactors
ETIM 8
EC000010 - Combination of contactors
ETIM 9
EC000010 - Combination of contactors
eClass
V11.0 : 27371003
UNSPSC
39121529
Three-pole design with 3 NO main contacts and two auxiliary NO/NC contacts reduces wiring complexity. This configuration improves panel density and simplifies control wiring, cutting commissioning time in new builds. It is well suited for 3-phase motors in packaging lines and material-handling conveyors. Rated Operational Voltage up to 690 V for main and auxiliary circuits enables operation with high-power mains and international installations, reducing the need for multiple devices and simplifying spare parts stocking. This makes it ideal for conveyors, fans, and process lines that require reliable high-voltage switching. DC coil control from 48–130 V (50/60 Hz) and DC operation facilitates direct interfacing with standard PLCs and automation networks, minimizing interface hardware and potential signal degradation. The device also features low coil power loss per pole, improving overall energy efficiency in continuous duty applications. DIN rail mounting options TH35-15 and TH35-7.5, plus the option for mounting by screws, enable fast, flexible installation in varied panel configurations. This reduces install time and supports modular panel designs for OEMs and system integrators. Tightening torque values (Auxiliary 1.2 N·m, Control 1.2 N·m, Main 4 N·m) and screw-terminal connections support secure, vibration-resistant wiring with flexible/rigid conductor options up to 35 mm². This improves reliability in harsh industrial environments and simplifies field maintenance. Certifications and environmental compliance include IEC/EN 60947-1, 60947-4-1, UL 60335-2-40, CSA, RoHS, REACH, and WEEE alignment. Such broad compliance reduces regulatory risk for global deployments and supports cross-border procurement and installation in manufacturing sites.
Get a Quick Quote for a ABB 1SBX208321R1222
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SBX208321R1222?
Enquire Now
FAQs
This reversing contactor supports DIN rail mounting on TH35-15 or TH35-7.5 rails and offers screw mounting as an alternative. The compact 110 mm width and 144 mm depth simplify panel design, while screw-terminal connections handle flexible or rigid conductors up to 35 mm². These options enable fast, scalable integration into OEM panels and control cabinets.
The device features a main circuit rated up to 690 V with three NO main contacts and two NO/NC auxiliary contacts. Rated operational currents include AC-3 and AC-3e across multiple voltages, and the unit supports 48–130 V control voltage (50/60 Hz) or DC operation for the coil, enabling broad compatibility with standard industrial controls.
Yes. With three poles and 22 kW AC-3 rated power at typical mains voltages, plus robust short-time withstand performance, this contactor is well-suited for high-inertia loads. Its UL/CSA and EN/IEC certifications, along with compact enclosure and reliable terminal connections, support durable performance in demanding production environments.
The product complies with IEC/EN 60947-1 and IEC/EN 60947-4-1, and is certified under UL 60335-2-40 and CSA. It also carries RoHS and REACH declarations, with WEEE alignment for B2B applications. These certifications help ensure global regulatory compliance and safer, more reliable operation in multinational facilities.
The ROI benefits arise from reduced wiring complexity, faster installation, and improved reliability. DIN-rail mounting with compact dimensions lowers enclosure space and labor costs, while UL/CSA compliance reduces regulatory risk and minimizes downtime due to regulatory findings. Combined, these factors contribute to lower total cost of ownership over equipment life cycles.