ABB 1SBX209321R1322 Contactor Starter - IEC 60947-4-1
Part Number: 1SBX209321R1322
Quick Summary
ABB 1SBX209321R1322 Contactor Starter is a compact motor-control device designed for reliable switching of three-phase loads in industrial panels. Engineers often face tight spaces, mixed voltage standards, and the need for quick, safe wiring. This model addresses those challenges with a 690 V main circuit and a 100–250 V control circuit, plus DIN-rail mounting options for TH35 rails. It meets core safety standards including IEC/EN 60947-1 and IEC/EN 60947-4-1, along with UL 60335-2-40 family compliance for broader certification coverage. By offering 3 main NO contacts and 2 auxiliary NO contacts, it supports robust control logic while minimizing panel footprint. This combination delivers improved reliability, reduced inventory, and faster panel assembly for automated systems.
Product Information
Extended Description
1SBX209321R1322 ABB: AF52R-30-22-13 100-250V50/60HZ-DC Reversing Contactor
Minimum Order Quantity
1 piece
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
110 mm
Product Net Depth / Length
144 mm
Product Net Height
151 mm
Product Net Weight
2.09 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Control Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Rated Operational Current AC-1 (Ie)
(1000 V) 60 °C 80 A | (690 V) 40 °C 100 A | (690 V) 70 °C 70 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 53 A | (440 V) 60 °C 53 A | (500 V) 60 °C 45 A | (690 V) 60 °C 35 A | (380 / 400 V) 60 °C 53 A | (220 / 230 / 240 V) 60 °C 53 A
Rated Operational Current AC-3e (Ie)
(415 V) 60 °C 53 A | (440 V) 60 °C 53 A | (500 V) 60 °C 45 A | (690 V) 60 °C 35 A | (380 / 400 V) 60 °C 53 A | (220 / 230 / 240 V) 60 °C 53 A
Rated Operational Current AC-15 (Ie)
(500 V) 2 A | (690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (400 / 440 V) 3 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (48 V) 2.8 A / 134 W | (72 V) 1 A / 72 W | (110 V) 0.55 A / 60 W | (125 V) 0.55 A / 69 W | (220 V) 0.27 A / 60 W | (250 V) 0.27 A / 68 W | (400 V) 0.15 A / 60 W | (500 V) 0.13 A / 65 W | (600 V) 0.1 A / 60 W
Rated Operational Power AC-3 (Pe)
(415 V) 30 kW | (440 V) 30 kW | (500 V) 30 kW | (690 V) 30 kW | (380 / 400 V) 22 kW | (220 / 230 / 240 V) 15 kW
Rated Operational Power AC-3e (Pe)
(415 V) 30 kW | (440 V) 30 kW | (500 V) 30 kW | (690 V) 30 kW | (380 / 400 V) 22 kW | (220 / 230 / 240 V) 15 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A | for 0.1 s 140 A | for 1 s 100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 690 V | acc. to IEC 60947-5-1 690 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
6 kV
Maximum Electrical Switching Frequency
(AC-15) 1200 cycles per hour | (DC-13) 900 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 100 ... 250 V | 60 Hz 100 ... 250 V | DC Operation 100 ... 250 V
Coil Consumption
Average Holding Value 50 / 60 Hz 4 V·A | Average Holding Value 50 Hz 4 V·A | Average Holding Value 60 Hz 4 V·A | Average Holding Value DC 2 W | Average Holding Value, from Warm State 2 W
Power Loss
at 6 A per Pole 0.1 W | at Rated Operating Conditions AC-1 per Pole 6.3 W | at Rated Operating Conditions AC-3 per Pole 1.7 W
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 or 2 x M6 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 4 ... 35 mm² | Flexible with Insulated Ferrule 1/2x 4 ... 35 mm² | Rigid Stranded 1/2x 6 ... 35 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid Solid 1/2x 1 ... 2.5 mm² | Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Auxiliary Circuit 10 mm | Control Circuit 10 mm | Main Circuit 16 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Recommended Screw Driver
Pozidriv PZ
Tightening Torque
Auxiliary Circuit 1.2 N·m | Control Circuit 1.2 N·m | Main Circuit 4 N·m
Terminal Type
Screw Terminals
Product Name
Contactor Starter
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
Connecting Capacity Main Circuit UL/CSA
Rigid Stranded 1/2x 10-2 AWG
Connecting Capacity Control Circuit UL/CSA
Rigid Solid 1/2x 18-14 AWG | Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA
Auxiliary Circuit 11 in·lb | Control Circuit 11 in·lb | Main Circuit 35 in·lb
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C
Pollution Degree
3
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
A2L Certificate – UL
UL-US Certificate of Compliance AF40 ... AF96 3-pole contactors - UL 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers | UL-CA Certificate of Compliance AF40 ... AF96 3-pole contactors - CSA C22.2 No. 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers
CB Certificate
CB Certificate AF(S)40(B), (S)AF52(B), AF(S)65(B) 3 and 4-pole contactors
CCC Certificate
CQC Certificate, Contactor, AF*40-30-**-**, AF40-40-**-**, AF40-22-**-**, AF*52-30-**-**, AF52-40-**-**,AF*65-30-**-**, Made in France
UL Certificate
UL-US-L312527-1141-10303102-9 | UL-CA-L312527-4141-10303102-9
Package Level 1 Units
box 1 piece
Package Level 1 Gross Weight
2.29 kg
Package Level 1 EAN
3471523020009
Object Classification Code
Q
ETIM 7
EC000010 - Combination of contactors
ETIM 8
EC000010 - Combination of contactors
ETIM 9
EC000010 - Combination of contactors
eClass
V11.0 : 27371003
UNSPSC
39121529
Feature: Wide voltage compatibility across main and control circuits → Business Impact: Simplifies sourcing and reduces spare-parts inventory, enabling faster, globally compliant installations → Application: Ideal for international motor-control panels using 690 V mains and 100–250 V control signals. Feature: 3NO main contacts with 2 NO auxiliary contacts → Business Impact: Enhanced control logic capacity and signaling without increasing panel footprint → Application: Reliable sequencing for motor starters, conveyors, and pumps in compact control cabinets. Feature: DIN-rail mounting with TH35-15 and TH35-7.5 options → Business Impact: Fast, setback-free installation with standardized panel layouts → Application: Typical DIN-rail mounted drives and starter assemblies in machine builders. Feature: Robust safety and regulatory compliance (IEC/EN 60947-1, IEC/EN 60947-4-1, UL/CSA) → Business Impact: Reduces regulatory risk and supports global product deployment → Application: Suitable for equipment intended for multiple markets with strict safety requirements. Feature: High-breaking capacity and defined switching frequency → Business Impact: Protects connected loads and minimizes downtime during switching events → Application: Motor loads, pumps, and automated process lines operating at varying duty cycles. Feature: Flexible wiring and terminal options (Screw Terminals; ferrule and solid/stranded conductors) → Business Impact: Simplifies field wiring, improves reliability, and speeds commissioning → Application: Panels with mixed conductor types and standard field-installation practices.
Get a Quick Quote for a ABB 1SBX209321R1322
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SBX209321R1322?
Enquire Now
FAQs
Install the device on a TH35 DIN rail (TH35-15 or TH35-7.5) by snapping it into place and securing it with the included mounting method. Connect the Main Circuit using Flexible Ferrule 1/2x 4-35 mm² or Rigid/Stranded 1/2x 6-35 mm², then tighten Main terminals to 4 N·m. Wire the Control Circuit with 0.75–2.5 mm² conductors and tighten to 1.2 N·m. Ensure proper stripping length (Main 16 mm, Auxiliary/Control 10 mm) and verify IP10 protection.
AC-3 ratings vary by voltage: at 415 V, 60 °C the unit supports 53 A; at 440 V, 60 °C also 53 A; at 500 V, 60 °C 45 A; at 690 V, 60 °C 35 A; and at 380–400 V, 60 °C 53 A, with 220–240 V ratings at 53 A. AC-3e matches AC-3 ratings for these voltages, ensuring consistent switching performance in motor-starting applications.
Yes. The product carries UL/CSA documentation (UL-US and UL-CA) and CB/CCC certificates for cross-market acceptance. It aligns with UL 60335-2-40 and related safety standards, enabling use in diverse regions. Verify specific regional certifications for your country or customer requirements during procurement.
Main circuit terminals accept 1/2x 4–35 mm² conductors with a tightening torque of 4 N·m. Control circuit terminals accept flexible ferrules 0.75–2.5 mm² with 1.2 N·m torque, and control torque rated at 1.2 N·m for auxiliary. UL/CSA torque values differ: auxiliary 11 in·lb, control 11 in·lb, and main 35 in·lb. Use correct stripping lengths: main 16 mm, auxiliary/control 10 mm.
Designed for three-phase motor control in industrial panels, suitable for conveyors, pumps, fans, and machine tools. Its 690 V main circuit, 100–250 V control, and 3 NO main plus 2 NO auxiliary contacts support reliable motor-start sequences with compact DIN-rail mounting, enabling efficient, scalable automation in production lines and control cabinets.