ABB 1SBX211321R1222 Reversing Contactor - UL 60335-2-40

Part Number: 1SBX211321R1222
Manufacturer
ABB
Part number
1SBX211321R1222

Quick Summary

ABB 1SBX211321R1222 Reversing Contactor enables precise motor reversal for automation panels and conveyor lines. Engineers often confront voltage fluctuations, limited panel space, and wiring complexity when upgrading legacy starters, risking downtime and miswiring. This device complies with IEC/EN 60947-1 and IEC/EN 60947-4-1, and carries UL 60335-2-40 and CSA certifications for North American safety, increasing trusted interoperability. With a compact DIN rail TH35-15 footprint and screw-terminal connections, installation is streamlined in tight panels. The coil accepts 48–130 V control signals at 50/60 Hz and supports 3P main contacts with 2 NO and 2 NC auxiliary contacts, delivering scalable control for diverse automation applications while maintaining robust protection and long service life.

Product Information

Extended Description

1SBX211321R1222 ABB: AF80R-30-22-12 48-130V50/60HZ-DC Reversing Contactor
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
140 mm
Product Net Depth / Length
149 mm
Product Net Height
151 mm
Product Net Weight
2.934 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 1000 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Control Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Rated Operational Current AC-1 (Ie)
(1000 V) 60 °C 100 A | (690 V) 40 °C 125 A | (690 V) 70 °C 85 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 80 A | (440 V) 60 °C 80 A | (500 V) 60 °C 65 A | (690 V) 60 °C 49 A | (1000 V) 60 °C 25 A | (380 / 400 V) 60 °C 80 A | (220 / 230 / 240 V) 60 °C 80 A
Rated Operational Current AC-3e (Ie)
(415 V) 60 °C 80 A | (440 V) 60 °C 80 A | (500 V) 60 °C 65 A | (690 V) 60 °C 49 A | (380 / 400 V) 60 °C 80 A | (220 / 230 / 240 V) 60 °C 80 A
Rated Operational Current AC-15 (Ie)
(500 V) 2 A | (690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (400 / 440 V) 3 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (48 V) 2.8 A / 134 W | (72 V) 1 A / 72 W | (110 V) 0.55 A / 60 W | (125 V) 0.55 A / 69 W | (220 V) 0.27 A / 60 W | (250 V) 0.27 A / 68 W | (400 V) 0.15 A / 60 W | (500 V) 0.13 A / 65 W | (600 V) 0.1 A / 60 W
Rated Operational Power AC-3 (Pe)
(415 V) 45 kW | (440 V) 45 kW | (500 V) 45 kW | (690 V) 45 kW | (1000 V) 35 kW | (380 / 400 V) 37 kW | (220 / 230 / 240 V) 22 kW
Rated Operational Power AC-3e (Pe)
(415 V) 45 kW | (440 V) 45 kW | (500 V) 45 kW | (690 V) 45 kW | (380 / 400 V) 37 kW | (220 / 230 / 240 V) 22 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 780 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 140 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1200 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 450 A | for 0.1 s 140 A | for 1 s 100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1150 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 750 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 1000 V | acc. to IEC 60947-5-1 690 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
8 kV
Maximum Electrical Switching Frequency
(AC-15) 1200 cycles per hour | (DC-13) 900 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 48 ... 130 V | 60 Hz 48 ... 130 V | DC Operation 48 ... 130 V
Power Loss
at 6 A per Pole 0.1 W | at Rated Operating Conditions AC-1 per Pole 7.6 W | at Rated Operating Conditions AC-3 per Pole 3 W
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 or 2 x M6 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 6 ... 50 mm² | Flexible with Insulated Ferrule 1/2x 6 ... 50 mm² | Rigid Stranded 1x 6 ... 70 mm² | Rigid Stranded 2x 6 ... 50 mm²
Wire Stripping Length
Auxiliary Circuit 10 mm | Control Circuit 10 mm | Main Circuit 17 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Tightening Torque
Auxiliary Circuit 1.2 N·m | Control Circuit 1.2 N·m | Main Circuit 6 N·m
Terminal Type
Screw Terminals
Product Name
Contactor Starter
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
Connecting Capacity Main Circuit UL/CSA
Rigid Stranded 1/2x 6-1 AWG
Tightening Torque UL/CSA
Auxiliary Circuit 11 in·lb | Control Circuit 11 in·lb | Main Circuit 53 in·lb
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C
Pollution Degree
3
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
A2L Certificate – UL
UL-US Certificate of Compliance AF40 ... AF96 3-pole contactors - UL 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers | UL-CA Certificate of Compliance AF40 ... AF96 3-pole contactors - CSA C22.2 No. 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers
UL Certificate
UL-US-L312527-1141-10303102-9 | UL-CA-L312527-4141-10303102-9
Package Level 1 Units
box 1 piece
Package Level 1 Gross Weight
3.234 kg
Package Level 1 EAN
3471523020078
ETIM 7
EC000010 - Combination of contactors
ETIM 8
EC000010 - Combination of contactors
ETIM 9
EC000010 - Combination of contactors
eClass
V11.0 : 27371003
UNSPSC
39121529
Feature → Business Impact → Application: 3P main contactset (3NO) with 2 NO and 2 NC auxiliary contacts simplifies motor control, reducing parts count and wiring complexity while enabling compact enclosures for conveyors and machine tools. This translates to faster panel assembly and lower installation costs. Feature → Business Impact → Application: 48–130 V control voltage at 50/60 Hz enables direct integration with common PLC/LCD operator signals, minimizing adapters and wiring errors in control cabinets. Application: panel upgrades and new installations across automated lines. Feature → Business Impact → Application: High rated currents (AC-3 up to 80 A at 415/440/500 V; DC-13 up to 60+ W depending on voltage) deliver reliable start/stop of motors with reduced wear, improving uptime in pumps and fans. Application: heavy machinery and packaging lines. Feature → Business Impact → Application: Power loss per pole (0.1 W at 6 A; 7.6 W AC-1; 3 W AC-3) supports energy-efficient operation and lower thermal load in crowded cabinets. Application: energy-conscious automation. Feature → Business Impact → Application: DIN rail mounting TH35-15 and screw-terminal connections simplify retrofits and new builds, enabling quick field wiring and robust vibration resistance. Application: modern control panels in food, packaging, and material handling. Feature → Business Impact → Application: Compliance with IEC/EN and UL/CSA standards ensures global suitability and easier supplier qualification. Application: multinational manufacturing environments requiring consistent safety and performance. Feature → Business Impact → Application: Universal mounting and wiring guidance (6–50 mm² conductor ranges, 1/2x 6–50 mm², 2x M4/M6 screws) reduces install time and improves reliability in tight spaces. Application: compact subpanels and retrofit projects. Feature → Business Impact → Application: Robust environmental and safety declarations (RoHS, REACH, TSCA, WEEE) support responsible supply chains and global procurement. Application: regulated industries with strict compliance needs.

Get a Quick Quote for a ABB 1SBX211321R1222

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBX211321R1222? Enquire Now

FAQs

This reversing cont actor is designed for DIN rail TH35-15 mounting and uses screw terminals for all connections. Main circuit supports Flexible with Ferrule 1/2x 6 … 50 mm² and Rigid Stranded up to 70 mm²; Auxiliary and Control circuits use the same screw terminal approach. For wiring, maintain the recommended 10 mm auxiliary/control wire stripping lengths and 17 mm for main circuit to ensure reliable terminations.
AC-3 ratings reach up to 80 A at 415–440–500 V and 60 A at 690 V, with AC-3e values similarly high for 415–440–690 V ranges. AC-1 ratings go up to 100 A at 1000 V (60 °C), while DC-13 ratings cover several coil voltages from 24 to 600 V depending on the circuit. These specs enable robust motor control in mixed-voltage environments.
Yes. The device provides 3P main contacts with AC-3 and AC-3e ratings for 380/400/415/440/500/690 V systems, plus a DC control option. It also offers a 1000 V insulation voltage and a 8 kV impulse withstand, making it well-suited for mid-to-high voltage motor starting tasks in machine tools, conveyors, and packaging lines.
The contactor complies with IEC/EN 60947-1 and IEC/EN 60947-4-1, and carries UL 60335-2-40 and CSA listings for North American safety. RoHS, REACH, TSCA declarations, and WEEE classification (B2B) support regulatory compliance across global supply chains, easing procurement for multinational facilities.
Regular inspection of terminal tightness (Main 6 N·m, Auxiliary/Control 1.2 N·m per spec), along with periodic contact resistance checks, helps prevent nuisance trips. The device’s high short-time withstand current and robust insulation reduce downtime during peak loads, delivering lower maintenance costs and improved equipment uptime in continuous process environments.