ABB 1SBX211321R1422 Contactor - IEC/UL Certified
Part Number: 1SBX211321R1422
Quick Summary
ABB 1SBX211321R1422 Contactor is a three-pole reversing starter designed for reliable motor control in demanding industrial environments. This compact device simplifies mid to large drive applications by consolidating main and auxiliary contacts in a single unit. A common pain point is wiring complexity and inconsistent performance under temperature fluctuations; this model mitigates both with robust screw terminals and proven insulation. It carries IEC/EN 60947-1, IEC/EN 60947-4-1, and UL/CSA certifications, providing confidence across engineering, procurement, and operations. With DIN-rail mounting and a broad voltage range, it supports scalable panel builds while maintaining safety and efficiency. For maintenance teams, predictable switching characteristics and well-documented compatibility translate into smoother commissioning and reduced total cost of ownership.
Product Information
Extended Description
1SBX211321R1422 ABB: AF80R-30-22-14 250-500V50/60HZ-DC Reversing Contactor
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
140 mm
Product Net Depth / Length
149 mm
Product Net Height
151 mm
Product Net Weight
2.892 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 1000 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Control Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Rated Operational Current AC-1 (Ie)
(1000 V) 60 °C 100 A | (690 V) 40 °C 125 A | (690 V) 70 °C 85 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 80 A | (440 V) 60 °C 80 A | (500 V) 60 °C 65 A | (690 V) 60 °C 49 A | (1000 V) 60 °C 25 A | (380 / 400 V) 60 °C 80 A | (220 / 230 / 240 V) 60 °C 80 A
Rated Operational Current AC-3e (Ie)
(415 V) 60 °C 80 A | (440 V) 60 °C 80 A | (500 V) 60 °C 65 A | (690 V) 60 °C 49 A | (380 / 400 V) 60 °C 80 A | (220 / 230 / 240 V) 60 °C 80 A
Rated Operational Current AC-15 (Ie)
(500 V) 2 A | (690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (400 / 440 V) 3 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (48 V) 2.8 A / 134 W | (72 V) 1 A / 72 W | (110 V) 0.55 A / 60 W | (125 V) 0.55 A / 69 W | (220 V) 0.27 A / 60 W | (250 V) 0.27 A / 68 W | (400 V) 0.15 A / 60 W | (500 V) 0.13 A / 65 W | (600 V) 0.1 A / 60 W
Rated Operational Power AC-3 (Pe)
(415 V) 45 kW | (440 V) 45 kW | (500 V) 45 kW | (690 V) 45 kW | (1000 V) 35 kW | (380 / 400 V) 37 kW | (220 / 230 / 240 V) 22 kW
Rated Operational Power AC-3e (Pe)
(415 V) 45 kW | (440 V) 45 kW | (500 V) 45 kW | (690 V) 45 kW | (380 / 400 V) 37 kW | (220 / 230 / 240 V) 22 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 780 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 140 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1200 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 450 A | for 0.1 s 140 A | for 1 s 100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1150 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 750 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 1000 V | acc. to IEC 60947-5-1 690 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
8 kV
Maximum Electrical Switching Frequency
(AC-15) 1200 cycles per hour | (DC-13) 900 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 250 ... 500 V | 60 Hz 250 ... 500 V | DC Operation 250 ... 500 V
Power Loss
at 6 A per Pole 0.1 W | at Rated Operating Conditions AC-1 per Pole 7.6 W | at Rated Operating Conditions AC-3 per Pole 3 W
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 or 2 x M6 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 6 ... 50 mm² | Flexible with Insulated Ferrule 1/2x 6 ... 50 mm² | Rigid Stranded 1x 6 ... 70 mm² | Rigid Stranded 2x 6 ... 50 mm²
Wire Stripping Length
Auxiliary Circuit 10 mm | Control Circuit 10 mm | Main Circuit 17 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Tightening Torque
Auxiliary Circuit 1.2 N·m | Control Circuit 1.2 N·m | Main Circuit 6 N·m
Terminal Type
Screw Terminals
Product Name
Contactor Starter
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
Connecting Capacity Main Circuit UL/CSA
Rigid Stranded 1/2x 6-1 AWG
Tightening Torque UL/CSA
Auxiliary Circuit 11 in·lb | Control Circuit 11 in·lb | Main Circuit 53 in·lb
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C
Pollution Degree
3
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
A2L Certificate – UL
UL-US Certificate of Compliance AF40 ... AF96 3-pole contactors - UL 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers | UL-CA Certificate of Compliance AF40 ... AF96 3-pole contactors - CSA C22.2 No. 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers
UL Certificate
UL-US-L312527-1141-10303102-9 | UL-CA-L312527-4141-10303102-9
Package Level 1 Units
box 1 piece
Package Level 1 Gross Weight
3.192 kg
Package Level 1 EAN
3471523020092
ETIM 7
EC000010 - Combination of contactors
ETIM 8
EC000010 - Combination of contactors
ETIM 9
EC000010 - Combination of contactors
eClass
V11.0 : 27371003
UNSPSC
39121529
Feature: Three main normally open contacts (NO) and zero normally closed (NC) contacts, plus two NO and two NC auxiliary contacts. Impact: Expands control logic and reduces external interlocks, enabling compact control schemes and faster wiring. Application: Ideal for synchronized motor control in conveyors and pumps where multiple control paths are required. Feature: Rated main circuit voltage up to 1000 V and auxiliary circuit up to 690 V. Impact: Supports versatile power ranges, enabling use across different machines and regional standards. Application: Suitable for high-voltage panels and mixed-voltage systems in metalworking or processing lines. Feature: Rated currents AC-1 up to 100 A and AC-3 up to 80 A (depending on voltage). Impact: Improves motor starting performance and reduces the need for external contactors or relays. Application: Suitable for general purpose drives and fans in HVAC and material handling. Feature: DIN rail mounting TH35-15 plus screw terminal option. Impact: Eases retrofit and installation, reduces enclosure space, and simplifies panel layouts. Application: Fast integration in new builds and upgrade projects. Feature: Power loss and energy efficiency data (0.1 W per pole at 6 A; 7.6 W at AC-1; 3 W at AC-3). Impact: Lower energy consumption and cooler operation, contributing to longer device life. Application: Critical in high-cycle applications like packaging lines and sorting systems. Feature: Robust environmental and safety specs (‑40 to 70 °C, IP10 terminals, UL/CSA and RoHS/REACH compliance). Impact: Reliable operation in harsh industrial environments with regulatory peace of mind. Application: Suitable for outdoor or harsh indoor panels with stringent compliance requirements. Feature: Comprehensive documentation and compatibility (2 x M4/M6 diagonal mounting, 1/2x6–50 mm² flexible wiring, 6–50 mm² ferrules). Impact: Streamlined commissioning and maintenance, reduced risk of wiring faults. Application: Works across a wide range of OEM and end-user installations, from machines to packaging lines.
Get a Quick Quote for a ABB 1SBX211321R1422
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SBX211321R1422?
Enquire Now
FAQs
The unit supports DIN rail mounting on TH35-15 (35x15 mm) for quick panel integration, and it can be screwed to a chassis using 2 x M4 or 2 x M6 screws placed diagonally. This flexibility simplifies retrofits and new panel builds alike, reducing installation time and potential wiring errors.
Main circuit voltage is rated up to 1000 V, auxiliary circuit up to 690 V, and control circuit voltage ranges from 250 to 500 V depending on the supply. Main contacts are 3 NO, with 2 NO and 2 NC auxiliaries, enabling versatile control logic for stop/start and reversing operations.
Yes. The model is a reversing contactor designed for DC operation within a 250–500 V range for the control circuit and supports DC reversing configurations in appropriate drive architectures, offering reliable bidirectional motor control when paired with compatible relays and drive logic.
It complies with IEC/EN 60947-1 and 60947-4-1, UL 60335-2-40, UL 60947-1, UL 60947-4-1, and CSA C22.2 No. 60335-2-40 as applicable, along with RoHS, REACH and CMRT disclosures. These certifications support global deployments and regulatory compliance on safety and environmental grounds.
Key benefits include documented wiring compatibility, predictable switching performance, and low power loss (0.1 W per pole at 6 A; 7.6 W at AC-1; 3 W at AC-3). This translates to reduced downtime, longer component life, and lower energy costs in high-cycle applications like packaging lines and conveyors.