ABB 1SBX212321R1122 Contactor Starter - IEC 60947-4-1

Part Number: 1SBX212321R1122
Manufacturer
ABB
Part number
1SBX212321R1122

Quick Summary

ABB 1SBX212321R1122 Contactor Starter is a 3-pole reversing contactor designed for motor control in industrial automation applications. It addresses common installer challenges such as limited footprint, wiring complexity, and strict regulatory requirements by combining a compact 3P main circuit with dual NO auxiliary contacts and convenient DIN rail mounting. The device complies with IEC/EN 60947-1 and IEC/EN 60947-4-1, and it carries UL 60335-2-40 and CSA listings along with RoHS and REACH declarations to simplify global sourcing. With a 24–60 V control voltage and up to 1000 V main circuit rating, it delivers reliable performance while saving space and reducing downtime on OEM lines and service interventions.

Product Information

Extended Description

1SBX212321R1122 ABB: AF96R-30-22-11 24-60V50/60HZ 20-60VDC Reversing Contactor
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
140 mm
Product Net Depth / Length
149 mm
Product Net Height
151 mm
Product Net Weight
2.768 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 1000 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Control Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Rated Operational Current AC-1 (Ie)
(1000 V) 60 °C 105 A | (690 V) 40 °C 130 A | (690 V) 70 °C 90 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 105 A | (440 V) 60 °C 105 A | (500 V) 60 °C 80 A | (690 V) 60 °C 57 A | (1000 V) 60 °C 30 A | (380 / 400 V) 60 °C 105 A | (220 / 230 / 240 V) 60 °C 105 A
Rated Operational Current AC-3e (Ie)
(415 V) 60 °C 96 A | (440 V) 60 °C 96 A | (500 V) 60 °C 80 A | (690 V) 60 °C 57 A | (380 / 400 V) 60 °C 105 A | (220 / 230 / 240 V) 60 °C 105 A
Rated Operational Current AC-15 (Ie)
(500 V) 2 A | (690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (400 / 440 V) 3 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (48 V) 2.8 A / 134 W | (72 V) 1 A / 72 W | (110 V) 0.55 A / 60 W | (125 V) 0.55 A / 69 W | (220 V) 0.27 A / 60 W | (250 V) 0.27 A / 68 W | (400 V) 0.15 A / 60 W | (500 V) 0.13 A / 65 W | (600 V) 0.1 A / 60 W
Rated Operational Power AC-3 (Pe)
(415 V) 55 kW | (440 V) 55 kW | (500 V) 55 kW | (690 V) 55 kW | (1000 V) 40 kW | (380 / 400 V) 45 kW | (380 / 400 V) 55 kW | (220 / 230 / 240 V) 25 kW | (220 / 230 / 240 V) 30 kW
Rated Operational Power AC-3e (Pe)
(415 V) 55 kW | (440 V) 55 kW | (500 V) 55 kW | (690 V) 55 kW | (380 / 400 V) 45 kW | (380 / 400 V) 55 kW | (220 / 230 / 240 V) 25 kW | (220 / 230 / 240 V) 30 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 840 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 140 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1200 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 450 A | for 0.1 s 140 A | for 1 s 100 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 1000 V | acc. to IEC 60947-5-1 690 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
8 kV
Maximum Electrical Switching Frequency
(AC-15) 1200 cycles per hour | (DC-13) 900 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 24 ... 60 V | 60 Hz 24 ... 60 V | DC Operation 20 ... 60 V
Power Loss
at 6 A per Pole 0.1 W | at Rated Operating Conditions AC-1 per Pole 8.2 W | at Rated Operating Conditions AC-3 per Pole 4.5 W
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 or 2 x M6 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 6 ... 50 mm² | Flexible with Insulated Ferrule 1/2x 6 ... 50 mm² | Rigid Stranded 1x 6 ... 70 mm² | Rigid Stranded 2x 6 ... 50 mm²
Wire Stripping Length
Auxiliary Circuit 10 mm | Control Circuit 10 mm | Main Circuit 17 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Tightening Torque
Auxiliary Circuit 1.2 N·m | Control Circuit 1.2 N·m | Main Circuit 6 N·m
Terminal Type
Screw Terminals
Product Name
Contactor Starter
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
Connecting Capacity Main Circuit UL/CSA
Rigid Stranded 1/2x 6-1 AWG
Tightening Torque UL/CSA
Auxiliary Circuit 11 in·lb | Control Circuit 11 in·lb | Main Circuit 53 in·lb
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C
Pollution Degree
3
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
A2L Certificate – UL
UL-US Certificate of Compliance AF40 ... AF96 3-pole contactors - UL 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers | UL-CA Certificate of Compliance AF40 ... AF96 3-pole contactors - CSA C22.2 No. 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers
UL Certificate
UL-US-L312527-1141-10303102-9 | UL-CA-L312527-4141-10303102-9
Package Level 1 Units
box 1 piece
Package Level 1 Gross Weight
3.068 kg
Package Level 1 EAN
3471523020108
ETIM 7
EC000010 - Combination of contactors
ETIM 8
EC000010 - Combination of contactors
ETIM 9
EC000010 - Combination of contactors
eClass
V11.0 : 27371003
UNSPSC
39121529
Feature → Business Impact → Application: The 3-pole NO main contact set (3P) with 2 NO/2 NC auxiliary contacts enables flexible motor control and remote signaling, reducing wiring complexity and shortening installation times on conveyors and pumps. This translates into measurable efficiency gains and lower total cost of ownership when deployed in automated lines. Feature → Business Impact → Application: Rated main circuit voltage up to 1000 V and auxiliary circuit up to 690 V support worldwide electrical standards, ensuring broad compatibility across regional installations and reducing part proliferation on multi-site projects. Application: High-voltage motor starter duties in material handling, water treatment, and industrial pumps.

Get a Quick Quote for a ABB 1SBX212321R1122

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBX212321R1122? Enquire Now

FAQs

The Contactor Starter is designed for TH35-15 DIN rail mounting. Secure the unit to the rail, then connect the main circuit terminals with flexible or rigid conductor per 6–50 mm² ranges, and attach the control wiring to the 24–60 V coil terminals. Ensure the terminals are tightened to 6 N·m for the main circuit and 1.2 N·m for auxiliary/control circuits to meet spec.
Rated AC-3 current is up to 105 A across voltages up to 690 V and down to 415–690 V as listed, with AC-1 ratings around 105 A at 415–690 V, and DC-13 ratings up to 0.27–0.55 A at higher DC voltages depending on voltage level. This makes the device suitable for motor starting and switching duty with high inductive loads.
Yes. The coil control voltage supports 24–60 V AC/DC, while the main circuit is rated up to 1000 V, and auxiliary circuit up to 690 V. This combination supports common control architectures (12/24 V or 48 V) and high-voltage motor control in compliant, safe configurations.
The device complies with IEC/EN 60947-1 and IEC/EN 60947-4-1, and carries UL 60335-2-40 and CSA listings. It also references RoHS II and REACH declarations, along with CMRT, WEEE B2B classification, and eClass ETIM classifications to support global procurement and regulatory requirements.
With a power loss of 0.1 W per pole at 6 A and up to 8.2 W (AC-1) or 4.5 W (AC-3) per pole under rated conditions, the unit offers low idle losses and predictable energy performance. Its robust insulation, screw-terminal reliability, and DIN rail mounting support reduce downtime during installation and maintenance while maintaining consistent switching performance under repetitive cycling.