ABB 1SBX212321R1322 Contactor Starter - UL/CSA Certified

Part Number: 1SBX212321R1322
Manufacturer
ABB
Part number
1SBX212321R1322

Quick Summary

ABB 1SBX212321R1322 Contactor Starter is a reversing contactor designed for motor start/stop and reversing applications in industrial panels. Engineers often struggle with compact integration, reliable switching, and panel space while meeting strict regulatory standards. This device adheres to IEC/EN 60947-1 and 60947-4-1, and carries UL/CSA listings for safety and compliance, along with RoHS/REACH declarations to support sustainability goals. By combining robust electrical performance with easy DIN rail mounting and clear terminal wiring guidance, it delivers faster commissioning, reduced hardware count, and lower lifecycle costs for control cabinets and machine ensembles.

Product Information

Extended Description

1SBX212321R1322 ABB: AF96R-30-22-13 100-250V50/60HZ-DC Reversing Contactor
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
140 mm
Product Net Depth / Length
149 mm
Product Net Height
151 mm
Product Net Weight
2.91 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 1000 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Control Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Rated Operational Current AC-1 (Ie)
(1000 V) 60 °C 105 A | (690 V) 40 °C 130 A | (690 V) 70 °C 90 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 105 A | (440 V) 60 °C 105 A | (500 V) 60 °C 80 A | (690 V) 60 °C 57 A | (1000 V) 60 °C 30 A | (380 / 400 V) 60 °C 105 A | (220 / 230 / 240 V) 60 °C 105 A
Rated Operational Current AC-3e (Ie)
(415 V) 60 °C 96 A | (440 V) 60 °C 96 A | (500 V) 60 °C 80 A | (690 V) 60 °C 57 A | (380 / 400 V) 60 °C 105 A | (220 / 230 / 240 V) 60 °C 105 A
Rated Operational Current AC-15 (Ie)
(500 V) 2 A | (690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (400 / 440 V) 3 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (48 V) 2.8 A / 134 W | (72 V) 1 A / 72 W | (110 V) 0.55 A / 60 W | (125 V) 0.55 A / 69 W | (220 V) 0.27 A / 60 W | (250 V) 0.27 A / 68 W | (400 V) 0.15 A / 60 W | (500 V) 0.13 A / 65 W | (600 V) 0.1 A / 60 W
Rated Operational Power AC-3 (Pe)
(415 V) 55 kW | (440 V) 55 kW | (500 V) 55 kW | (690 V) 55 kW | (1000 V) 40 kW | (380 / 400 V) 45 kW | (380 / 400 V) 55 kW | (220 / 230 / 240 V) 25 kW | (220 / 230 / 240 V) 30 kW
Rated Operational Power AC-3e (Pe)
(415 V) 55 kW | (440 V) 55 kW | (500 V) 55 kW | (690 V) 55 kW | (380 / 400 V) 45 kW | (380 / 400 V) 55 kW | (220 / 230 / 240 V) 25 kW | (220 / 230 / 240 V) 30 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 840 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 140 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1200 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 450 A | for 0.1 s 140 A | for 1 s 100 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 1000 V | acc. to IEC 60947-5-1 690 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
8 kV
Maximum Electrical Switching Frequency
(AC-15) 1200 cycles per hour | (DC-13) 900 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 100 ... 250 V | 60 Hz 100 ... 250 V | DC Operation 100 ... 250 V
Power Loss
at 6 A per Pole 0.1 W | at Rated Operating Conditions AC-1 per Pole 8.2 W | at Rated Operating Conditions AC-3 per Pole 4.5 W
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 or 2 x M6 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 6 ... 50 mm² | Flexible with Insulated Ferrule 1/2x 6 ... 50 mm² | Rigid Stranded 1x 6 ... 70 mm² | Rigid Stranded 2x 6 ... 50 mm²
Wire Stripping Length
Auxiliary Circuit 10 mm | Control Circuit 10 mm | Main Circuit 17 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Tightening Torque
Auxiliary Circuit 1.2 N·m | Control Circuit 1.2 N·m | Main Circuit 6 N·m
Terminal Type
Screw Terminals
Product Name
Contactor Starter
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
Connecting Capacity Main Circuit UL/CSA
Rigid Stranded 1/2x 6-1 AWG
Tightening Torque UL/CSA
Auxiliary Circuit 11 in·lb | Control Circuit 11 in·lb | Main Circuit 53 in·lb
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C
Pollution Degree
3
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
A2L Certificate – UL
UL-US Certificate of Compliance AF40 ... AF96 3-pole contactors - UL 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers | UL-CA Certificate of Compliance AF40 ... AF96 3-pole contactors - CSA C22.2 No. 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers
UL Certificate
UL-US-L312527-1141-10303102-9 | UL-CA-L312527-4141-10303102-9
Package Level 1 Units
box 1 piece
Package Level 1 Gross Weight
3.21 kg
Package Level 1 EAN
3471523020122
ETIM 7
EC000010 - Combination of contactors
ETIM 8
EC000010 - Combination of contactors
ETIM 9
EC000010 - Combination of contactors
eClass
V11.0 : 27371003
UNSPSC
39121529
Feature → Business Impact → Application: Reversing Contactor with 3P main contacts NO and 2 NO/2 NC auxiliary contacts enables reliable motor reversal and simplified control logic, reducing mis-wiring risk and improving uptime in conveyors and presses. Application: ideal for compact control panels where space is at a premium. Feature → Business Impact → Application: Main circuit rated up to 1000 V and auxiliary circuit up to 690 V across 50/60 Hz supports global installations, enabling a single part to serve multiple regional standards. Application: suitable for multi-voltage equipment in packaging lines and robotics. Feature → Business Impact → Application: DIN rail TH35-15 mounting plus screw-terminal options streamline installation, trimming panel depth and time-to-first-run. Application: rapid retrofits in retrofit-friendly control cabinets. Feature → Business Impact → Application: Power loss of 8.2 W per pole (AC-3) and 0.1 W per pole at 6 A (per pole) improves energy efficiency and thermal stability, reducing cooling requirements. Application: continuous operation in machine tools and material handling. Feature → Business Impact → Application: Robust operating range (-40 to 70 °C) and IP10 main terminals ensure reliable operation in harsh environments, with RoHS/REACH and UL/CSA certifications supporting governance and compliance. Application: heavy-duty industrial environments with demanding ambient conditions.

Get a Quick Quote for a ABB 1SBX212321R1322

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBX212321R1322? Enquire Now

FAQs

The device mounts on TH35-15 DIN rails for fast, secure installation in control cabinets. It also offers screw terminals for main, control, and auxiliary circuits, with wire stripping lengths of 17 mm for main circuits and 10 mm for auxiliary/control circuits. Conductor sizes range up to 70 mm² for rigid or ferrule-equipped flex, providing versatile, reliable terminations in compact spaces.
For AC-3 operation, the unit provides up to 57 A at 690 V, 30 A at 1000 V, and 105 A at lower voltages like 380/400 V. For AC-1, it handles up to 105 A at 1000 V, with 130 A at 690 V under 40 °C ambient. These ratings support high-demand motor control while ensuring safe, reliable switching.
Yes. With a 3P main contact configuration and 2 NO/2 NC auxiliary contacts, the ABB 1SBX212321R1322 is designed for reversing motor control in industrial panels. Its DC control voltage range and 50/60 Hz compatibility enable dependable start/stop and reversal in conveyors, pumps, and similar equipment, while DIN-rail mounting simplifies integration into existing cabinets.
This model aligns with IEC/EN 60947-1 and 60947-4-1 standards, and carries UL/CSA listings including UL/CSA 60335-2-40 references. It also includes RoHS and REACH declarations, along with ETIM 7–9 classifications and WEEE guidance for B2B environments, supporting procurement and regulatory requirements.
The device offers low per-pole power loss (0.1 W at 6 A per pole) and rated losses under AC-1 and AC-3 conditions (8.2 W and 4.5 W per pole, respectively), contributing to lower energy costs and reduced heat in panels. Combined with high reliability, UL/CSA compliance, and standard wiring practices, this translates to improved uptime and faster maintenance cycles.