ABB 1SBX212321R1422 Contactor Starter - IEC/UL/CSA Listed
Part Number: 1SBX212321R1422
Quick Summary
ABB 1SBX212321R1422 Contactor Starter is a three‑pole reversing contactor designed for motor control in automation panels. This device helps simplify start/stop sequencing while reducing wiring complexity in compact control cabinets. It carries essential certifications such as IEC/EN 60947-4-1, UL 60335-2-40, and CSA listings, supporting global compliance and safety requirements. With rated main and auxiliary voltages suited for mixed control schemes, it also offers DIN rail mounting and robust screw-terminal connections for reliable terminations. For panel builders and maintenance teams, the combination of compact form, standards alignment, and clear serviceability translates to lower installation risk and predictable lifecycle costs.
Product Information
Extended Description
1SBX212321R1422 ABB: AF96R-30-22-14 250-500V50/60HZ-DC Reversing Contactor
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
140 mm
Product Net Depth / Length
149 mm
Product Net Height
151 mm
Product Net Weight
2.908 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 1000 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Control Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Rated Operational Current AC-1 (Ie)
(1000 V) 60 °C 105 A | (690 V) 40 °C 130 A | (690 V) 70 °C 90 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 105 A | (440 V) 60 °C 105 A | (500 V) 60 °C 80 A | (690 V) 60 °C 57 A | (1000 V) 60 °C 30 A | (380 / 400 V) 60 °C 105 A | (220 / 230 / 240 V) 60 °C 105 A
Rated Operational Current AC-3e (Ie)
(415 V) 60 °C 96 A | (440 V) 60 °C 96 A | (500 V) 60 °C 80 A | (690 V) 60 °C 57 A | (380 / 400 V) 60 °C 105 A | (220 / 230 / 240 V) 60 °C 105 A
Rated Operational Current AC-15 (Ie)
(500 V) 2 A | (690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (400 / 440 V) 3 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (48 V) 2.8 A / 134 W | (72 V) 1 A / 72 W | (110 V) 0.55 A / 60 W | (125 V) 0.55 A / 69 W | (220 V) 0.27 A / 60 W | (250 V) 0.27 A / 68 W | (400 V) 0.15 A / 60 W | (500 V) 0.13 A / 65 W | (600 V) 0.1 A / 60 W
Rated Operational Power AC-3 (Pe)
(415 V) 55 kW | (440 V) 55 kW | (500 V) 55 kW | (690 V) 55 kW | (1000 V) 40 kW | (380 / 400 V) 45 kW | (380 / 400 V) 55 kW | (220 / 230 / 240 V) 25 kW | (220 / 230 / 240 V) 30 kW
Rated Operational Power AC-3e (Pe)
(415 V) 55 kW | (440 V) 55 kW | (500 V) 55 kW | (690 V) 55 kW | (380 / 400 V) 45 kW | (380 / 400 V) 55 kW | (220 / 230 / 240 V) 25 kW | (220 / 230 / 240 V) 30 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 840 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 140 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1200 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 450 A | for 0.1 s 140 A | for 1 s 100 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 1000 V | acc. to IEC 60947-5-1 690 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
8 kV
Maximum Electrical Switching Frequency
(AC-15) 1200 cycles per hour | (DC-13) 900 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 250 ... 500 V | 60 Hz 250 ... 500 V | DC Operation 250 ... 500 V
Power Loss
at 6 A per Pole 0.1 W | at Rated Operating Conditions AC-1 per Pole 8.2 W | at Rated Operating Conditions AC-3 per Pole 4.5 W
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 or 2 x M6 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 6 ... 50 mm² | Flexible with Insulated Ferrule 1/2x 6 ... 50 mm² | Rigid Stranded 1x 6 ... 70 mm² | Rigid Stranded 2x 6 ... 50 mm²
Wire Stripping Length
Auxiliary Circuit 10 mm | Control Circuit 10 mm | Main Circuit 17 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Tightening Torque
Auxiliary Circuit 1.2 N·m | Control Circuit 1.2 N·m | Main Circuit 6 N·m
Terminal Type
Screw Terminals
Product Name
Contactor Starter
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
Connecting Capacity Main Circuit UL/CSA
Rigid Stranded 1/2x 6-1 AWG
Tightening Torque UL/CSA
Auxiliary Circuit 11 in·lb | Control Circuit 11 in·lb | Main Circuit 53 in·lb
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C
Pollution Degree
3
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
A2L Certificate – UL
UL-US Certificate of Compliance AF40 ... AF96 3-pole contactors - UL 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers | UL-CA Certificate of Compliance AF40 ... AF96 3-pole contactors - CSA C22.2 No. 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers
UL Certificate
UL-US-L312527-1141-10303102-9 | UL-CA-L312527-4141-10303102-9
Package Level 1 Units
box 1 piece
Package Level 1 Gross Weight
3.208 kg
Package Level 1 EAN
3471523020146
ETIM 7
EC000010 - Combination of contactors
ETIM 8
EC000010 - Combination of contactors
ETIM 9
EC000010 - Combination of contactors
eClass
V11.0 : 27371003
UNSPSC
39121529
Feature → Business Impact → Application: 3P reversing contactor with 3 main NO contacts and 2 NO + 2 NC auxiliary contacts delivers compact control of motor reversing sequences, reducing panel footprint and wiring complexity in conveyors and pumps. This enables faster commissioning and lower assembly costs in machine tools and packaging lines. Feature → Application → Industry context: Rated operating voltage for main circuit up to 1000 V and auxiliary up to 690 V, with 50/60 Hz compatibility, supports diverse motor applications and international installations without reconfiguration, improving cross-site consistency. Feature → Business Impact → Application: AC-3 and DC-13 ratings across voltage ranges (e.g., 415–690 V AC-3 up to 105 A; DC-13 at multiple voltages) ensure reliable motor starting and stopping under varying load profiles, reducing downtime and enhancing process uptime. Feature → Application → Installation advantage: DIN rail mounting TH35-15 and screw-terminal wiring provide flexible mounting and robust terminations, improving vibration resistance and ease of service in harsh environments. Feature → Business Impact → Application: Low Power Loss (per pole 0.1 W; AC-1 8.2 W; AC-3 4.5 W) supports energy efficiency in continuous control applications, cutting running costs over the device lifetime. Feature → Application → Compliance: Wide range of standards and certifications (IEC/EN 60947‑1, 60947‑4‑1, UL/CSA) ensures regulatory alignment for global deployments, simplifying procurement and audit processes. Feature → Application → Compatibility: 140 mm width, 149 mm depth, 151 mm height, 2.908 kg weight, with 2×M4/M6 screw mounting options and 17 mm main-circuit wire stripping; this combination provides predictable fit in existing control panels and minimizes rework during retrofits.
Get a Quick Quote for a ABB 1SBX212321R1422
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SBX212321R1422?
Enquire Now
FAQs
This device supports TH35-15 DIN rail mounting for compact, multi‑bay panels, and it also offers screw mounting with 2 x M4 or 2 x M6 screws placed diagonally. The combination provides flexible installation in existing cabinets and simplifies retrofits in tight spaces.
Main circuit rated up to 1000 V, auxiliary up to 690 V with 50/60 Hz operation. Main contacts are 3 NO with 2 NO/2 NC auxiliary contacts, and the unit supports AC-3 up to 105 A at relevant voltages and DC-13 ratings across several voltages, enabling reliable motor control across diverse applications.
Yes. It carries UL 60335-2-40 and CSA listings, and complies with IEC/EN 60947-1 and 60947-4-1, among others. This combination supports regulatory compliance in North America and Europe, streamlining procurement and audits for multinational facilities.
Ideal for motor control in automation lines such as conveyors, pumps, fans, and machine tools. Its reversing capability, 3P configuration, and robust ratings support start/stop sequences, direction changes, and protection in demanding industrial environments.
The unit’s DIN rail compatibility, screw-terminal connections, moderate weight, and compact dimensions simplify installation and maintenance. Low power losses per pole reduce energy consumption, while wide voltage and current ratings minimize the need for replacement during upgrades, delivering predictable total cost of ownership over the equipment lifecycle.