Reversing Contactor ABB 1SBX304311R1122 - UL A2L
Part Number: 1SBX304311R1122
Quick Summary
Reversing Contactor is a coil-operated device used to reverse motor rotation in industrial drives and conveyors. Engineers often struggle with limited panel space, cable management, and the need for code-compliant safety in motor control circuits. This ABB model meets IEC/EN 60947-1 and 60947-4-1, UL 60335-2-40, and CSA safety certifications, providing trusted regulatory coverage. With 24–60 V control and 690 V main ratings, DIN-rail mounting compatibility, and a compact 3P footprint, it streamlines installation and reduces panel size. The unit also delivers low coil power loss per pole and flexible conductor connections, enabling energy savings and longer component life. For OEMs and integrators, this translates into faster commissioning, easier maintenance, and improved overall system reliability.
Product Information
Extended Description
1SBX304311R1122 ABB: AF26N1R-30-22-11 24-60V50/60HZ 20-60VDC Reversing Contactor
Minimum Order Quantity
1 piece
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
90 mm
Product Net Depth / Length
119.5 mm
Product Net Height
112.5 mm
Product Net Weight
0.768 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-4-1
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Control Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Rated Operational Current AC-1 (Ie)
(1000 V) 60 °C 40 A | (690 V) 40 °C 45 A | (690 V) 70 °C 32 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 26 A | (440 V) 60 °C 26 A | (500 V) 60 °C 23 A | (690 V) 60 °C 17 A | (380 / 400 V) 60 °C 26 A | (220 / 230 / 240 V) 60 °C 26 A
Rated Operational Current AC-3e (Ie)
(415 V) 60 °C 26 A | (440 V) 60 °C 26 A | (500 V) 60 °C 23 A | (690 V) 60 °C 17 A | (380 / 400 V) 60 °C 26 A | (220 / 230 / 240 V) 60 °C 26 A
Rated Operational Current AC-15 (Ie)
(500 V) 2 A | (690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (400 / 440 V) 3 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (48 V) 2.8 A / 134 W | (72 V) 1 A / 72 W | (110 V) 0.55 A / 60 W | (125 V) 0.55 A / 69 W | (220 V) 0.27 A / 60 W | (250 V) 0.27 A / 68 W | (400 V) 0.15 A / 60 W | (500 V) 0.13 A / 65 W | (600 V) 0.1 A / 60 W
Rated Operational Power AC-3 (Pe)
(415 V) 11 kW | (440 V) 15 kW | (500 V) 15 kW | (690 V) 15 kW | (380 / 400 V) 11 kW | (220 / 230 / 240 V) 6.5 kW
Rated Operational Power AC-3e (Pe)
(415 V) 11 kW | (440 V) 15 kW | (500 V) 15 kW | (690 V) 15 kW | (380 / 400 V) 11 kW | (220 / 230 / 240 V) 6.5 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 350 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 50 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 700 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A | for 0.1 s 140 A | for 1 s 100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 500 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 200 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 690 V | acc. to IEC 60947-5-1 690 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
6 kV
Maximum Electrical Switching Frequency
(AC-15) 1200 cycles per hour | (DC-13) 900 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 24 ... 60 V | 60 Hz 24 ... 60 V | DC Operation 20 ... 60 V
Power Loss
at 6 A per Pole 0.1 W | at Rated Operating Conditions AC-1 per Pole 1.8 W | at Rated Operating Conditions AC-3 per Pole 0.6 W
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 1.5 ... 10 mm² | Flexible with Insulated Ferrule 1x 1.5 ... 10 mm² | Flexible with Insulated Ferrule 2x 1.5 ... 4 mm² | Rigid Solid 1/2x 2.5 ... 4 mm² | Rigid Stranded 1/2x 2.5 ... 10 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid Solid 1/2x 1 ... 2.5 mm² | Rigid Stranded 1/2x 1 ... 2.5 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid Solid 1/2x 1 ... 2.5 mm² | Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Auxiliary Circuit 10 mm | Control Circuit 10 mm | Main Circuit 14 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Auxiliary Circuit 1.2 N·m | Control Circuit 1.2 N·m | Main Circuit 2.5 N·m
Terminal Type
Screw Terminals
Product Name
Contactor Starter
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
Connecting Capacity Main Circuit UL/CSA
Rigid Solid 1/2x 14-10 AWG | Rigid Stranded 1/2x 14-8 AWG
Connecting Capacity Auxiliary Circuit UL/CSA
Rigid Solid 1/2x 18-14 AWG | Rigid Stranded 1/2x 18-14 AWG
Connecting Capacity Control Circuit UL/CSA
Rigid Solid 1/2x 18-14 AWG | Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA
Auxiliary Circuit 11 in·lb | Control Circuit 11 in·lb | Main Circuit 22 in·lb
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 60 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C
Pollution Degree
3
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
A2L Certificate – UL
UL-US A2L LZGH2 Certificate of Compliance AF09 ... AF38 3-pole contactors with screw terminals - UL 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers | UL-CA A2L LZGH2 Certificate of Compliance AF09 ... AF38 3-pole contactors with screw terminals - CSA C22.2 No. 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers
CB Certificate
CB Certificate AF26(Z)(B), AF30(Z)(B), AF(Z)(B)38 3-pole contactors, AFS26, AFS30, AFS38 safety contactors
UL Certificate
UL-US Certificate of Compliance AF(C)(S)09(R/M/N)-..(L)(S)(K)...AF(C)(S)38(R/M/N)..(K) 3-pole contactors screw, spring and push-in spring terminals; LDC4 additional coil terminal block; LF16-4, LG16-4, LF38-4 and LH38-4 connecting strips, LD38-4 additional terminal block | UL-CA Certificate of Compliance AF(C)(S)09(R/M/N)-..(L)(S)(K)...AF(C)(S)38(R/M/N)..(K) 3-pole contactors screw, spring and push-in spring terminals; LDC4 additional coil terminal block; LF16-4, LG16-4, LF38-4 and LH38-4 connecting strips, LD38-4 additional terminal block
Package Level 1 Units
box 1 piece
Package Level 1 Gross Weight
2.268 kg
Package Level 1 EAN
3471523020351
ETIM 7
EC000010 - Combination of contactors
ETIM 8
EC000010 - Combination of contactors
ETIM 9
EC000010 - Combination of contactors
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4762 >> Nema Contactors
Feature: 3-pole design with 3 main normally-open (NO) contacts and 2 NO + 2 NC auxiliary contacts. Benefit: Enables reliable three-phase motor reversing with built-in interlock flexibility for conveyors, pumps, and machine tools. Application: Ideal for compact drives where space is at a premium and precise control is required. Long-tail keyword usage: three-pole contactor, motor reversing, auxiliary contacts. Business impact: reduces wiring complexity and panel footprint while improving startup sequencing and fault diagnostics. Feature: Rated main circuit voltage up to 690 V and auxiliary circuit up to 690 V with a 50/60 Hz operating window. Benefit: Supports broad plant voltages and rapid deployment in mixed-voltage environments. Application: Suitable for modular machine builders and OEM panels. Long-tail keywords: high-voltage contactor, AC-3 switching, multi-voltage devices. Measureable outcome: supports large motor loads with consistent switching performance. Feature: Rated control circuit voltage 24–60 V (AC 50/60 Hz) and DC 20–60 V. Benefit: Compatibility with common PLC and safety relay outputs, reducing control wiring complexity. Application: Industrial automation architecture with standard low-voltage control. Long-tail keywords: 24–60 V control, PLC compatibility, DC coil operation. Feature: DIN rail mounting options TH35-15 or TH35-7.5 and 2 x M4 mounting screws. Benefit: Fast, tool-friendly installation with reliable mechanical anchorage. Application: Step-in panel assemblies and retrofit installations. Long-tail keywords: DIN rail mounting, TH35, panel mounting. Feature: Screw terminals for main and auxiliary circuits with specific wire sizing and stripping lengths. Benefit: Simplified wiring and robust conductor termination for vibration-prone environments. Application: Control cabinets in manufacturing lines. Long-tail keywords: screw terminals, conductor sizing, vibration resistance. Feature: IP20 protection and solid environmental ratings with wide ambient temperature range. Benefit: Ensures dependable operation in typical工shop and factory environments with robust safety margins. Application: Industrial installations with moderate dust and humidity exposure. Long-tail keywords: IP20, ambient temperature -25 to 60 C. Feature: UL/CSA A2L certification coverage and CB/UL listings. Benefit: Accelerates regulatory approvals and end-customer acceptance for appliances and equipment. Application: Global product deployment in machinery and automation systems. Long-tail keywords: UL A2L certification, CSA safety, regulatory compliance.
Get a Quick Quote for a ABB 1SBX304311R1122
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SBX304311R1122?
Enquire Now
FAQs
This unit supports DIN rail mounting on TH35-15 or TH35-7.5 and is compatible with panel mounting using two M4 screws. Screw terminals are used for main, auxiliary, and control circuit connections, simplifying integration into compact control panels.
Yes. The rated control circuit voltage is 24–60 V (AC 50/60 Hz or DC 20–60 V), and the main circuit is rated up to 690 V. This makes it compatible with standard plant control logic and high-voltage motor circuits.
It complies with IEC/EN 60947-1 and 60947-4-1, UL 60335-2-40, UL 60947-4-1, CSA C22.2 No. 60335-2-40, and CSA C22.2 No. 60947-4-1, with UL A2L listing for appliance safety. CB certification is also documented for cross-border approvals.
AC-3 current ratings vary by voltage: up to 26 A at 415–500 V and up to 17 A at 690 V, with 26 A also listed for some 440 V scenarios. The main circuit supports up to 690 V, while the auxiliary circuit also shares a 690 V rating.
With low coil power loss per pole (about 0.6 W under AC-3) and robust DIN-rail mounting, installation and wiring are faster, heat generation is lower, and lifecycle costs decrease due to fewer field adjustments and longer relay life. Certifications simplify compliance and OEM support accelerates time to market.