ABB 1SBX305321R1122 Contactor Starter - IEC 60947-4-1
Part Number: 1SBX305321R1122
Quick Summary
ABB 1SBX305321R1122 Contactor Starter provides reliable motor control for compact machines and conveyors. Many engineers struggle with control gear that fits small panels while meeting safety and regulatory demands. This device aligns with IEC 60947-4-1, UL 60335-2-40, and CSA expectations, ensuring safe, compliant operation in diverse environments. With TH35 mounting on DIN rails and screw-terminal connections, it simplifies installation and minimizes field wiring errors. Rated for 690 V mains and up to 60 A in AC-1, AC-3, and AC-3e ranges, it supports 24–60 V control circuits and DC operation, making it a versatile choice for modern machine builders. Two auxiliary contacts and three main poles enable compact interlocking and status signaling, delivering tangible space and cost benefits.
Product Information
Extended Description
1SBX305321R1122 ABB: AF40N2R-30-22-11 24-60V50/60HZ 20-60VDC Reversing Contactor
Minimum Order Quantity
1 piece
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
110 mm
Product Net Depth / Length
144 mm
Product Net Height
151 mm
Product Net Weight
2.168 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Control Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Rated Operational Current AC-1 (Ie)
(1000 V) 60 °C 60 A | (690 V) 40 °C 70 A | (690 V) 70 °C 50 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 40 A | (440 V) 60 °C 40 A | (500 V) 60 °C 35 A | (690 V) 60 °C 25 A | (380 / 400 V) 60 °C 40 A | (220 / 230 / 240 V) 60 °C 40 A
Rated Operational Current AC-3e (Ie)
(415 V) 60 °C 40 A | (440 V) 60 °C 40 A | (500 V) 60 °C 35 A | (690 V) 60 °C 25 A | (380 / 400 V) 60 °C 40 A | (220 / 230 / 240 V) 60 °C 40 A
Rated Operational Current AC-15 (Ie)
(500 V) 2 A | (690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (400 / 440 V) 3 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (48 V) 2.8 A / 134 W | (72 V) 1 A / 72 W | (110 V) 0.55 A / 60 W | (125 V) 0.55 A / 69 W | (220 V) 0.27 A / 60 W | (250 V) 0.27 A / 68 W | (400 V) 0.15 A / 60 W | (500 V) 0.13 A / 65 W | (600 V) 0.1 A / 60 W
Rated Operational Power AC-3 (Pe)
(415 V) 22 kW | (440 V) 22 kW | (500 V) 22 kW | (690 V) 22 kW | (380 / 400 V) 18.5 kW | (220 / 230 / 240 V) 11 kW
Rated Operational Power AC-3e (Pe)
(415 V) 22 kW | (440 V) 22 kW | (500 V) 22 kW | (690 V) 22 kW | (380 / 400 V) 18.5 kW | (220 / 230 / 240 V) 11 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A | for 0.1 s 140 A | for 1 s 100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 690 V | acc. to IEC 60947-5-1 690 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
6 kV
Maximum Electrical Switching Frequency
(AC-15) 1200 cycles per hour | (DC-13) 900 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 24 ... 60 V | 60 Hz 24 ... 60 V | DC Operation 20 ... 60 V
Power Loss
at 6 A per Pole 0.1 W | at Rated Operating Conditions AC-1 per Pole 3 W | at Rated Operating Conditions AC-3 per Pole 1 W
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 or 2 x M6 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 4 ... 35 mm² | Flexible with Insulated Ferrule 1/2x 4 ... 35 mm² | Rigid Stranded 1/2x 6 ... 35 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid Solid 1/2x 1 ... 2.5 mm² | Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Auxiliary Circuit 10 mm | Control Circuit 10 mm | Main Circuit 16 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Tightening Torque
Auxiliary Circuit 1.2 N·m | Control Circuit 1.2 N·m | Main Circuit 4 N·m
Terminal Type
Screw Terminals
Product Name
Contactor Starter
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
Connecting Capacity Main Circuit UL/CSA
Rigid Stranded 1/2x 10-2 AWG
Connecting Capacity Control Circuit UL/CSA
Rigid Solid 1/2x 18-14 AWG | Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA
Auxiliary Circuit 11 in·lb | Control Circuit 11 in·lb | Main Circuit 35 in·lb
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C
Pollution Degree
3
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
A2L Certificate – UL
UL-US Certificate of Compliance AF40 ... AF96 3-pole contactors - UL 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers | UL-CA Certificate of Compliance AF40 ... AF96 3-pole contactors - CSA C22.2 No. 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers
CB Certificate
CB Certificate AF(S)40(B), (S)AF52(B), AF(S)65(B) 3 and 4-pole contactors
CCC Certificate
CQC Certificate, Contactor, AF*40-30-**-**, AF40-40-**-**, AF40-22-**-**, AF*52-30-**-**, AF52-40-**-**,AF*65-30-**-**, Made in France
UL Certificate
UL-US-L312527-1141-10303102-9 | UL-CA-L312527-4141-10303102-9
Package Level 1 Units
box 1 piece
Package Level 1 Gross Weight
3.668 kg
Package Level 1 EAN
3471523020399
ETIM 7
EC000010 - Combination of contactors
ETIM 8
EC000010 - Combination of contactors
ETIM 9
EC000010 - Combination of contactors
eClass
V11.0 : 27371003
UNSPSC
39121529
Feature a three-pole design with three main normally-open contacts and two auxiliary normally-open/normal-closed contacts delivers reliable motor switching while reducing circuit complexity. Business impact: improved interlocking, safer signaling, and easier wiring for conveyors and pumps. Application: ideal for compact pack-out lines and small automation cabinets. Feature a broad voltage capability with main circuit ratings up to 690 V and auxiliary up to 690 V, enabling a single device to cover diverse machine topsologies. Business impact: lowers part diversity and stock-keeping costs; Application: suitable for multi-voltage motor drives and mixed-load machines. Feature control circuitry rated for 50/60 Hz and a 24–60 V supply, including DC operation, which supports PLC-driven control. Business impact: simplifies integration with modern control architectures and reduces control-panel footprint. Application: ideal for drop-in replacements in existing control schemes. Feature mounting on DIN rails TH35-15 or TH35-7.5 and screw-terminal connections streamlines installation and service. Business impact: faster commissioning, robust connections, and easier field maintenance. Application: widely used in panel-building, machine builders, and retrofit projects. Feature compact dimensions and weight (110 mm width, 144 mm depth, 151 mm height, ~2.168 kg) for space-constrained panels. Business impact: enables smaller enclosures and reduced shipping/handling costs. Application: preferred in space-limited automation cabinets. Feature broad certification and compliance footprint including IEC/EN 60947-1, IEC/EN 60947-4-1, UL/CSA and RoHS declarations. Business impact: mitigates regulatory risk and accelerates customer approvals. Application: essential for regulated industrial environments and global deployments.
Get a Quick Quote for a ABB 1SBX305321R1122
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SBX305321R1122?
Enquire Now
FAQs
This device supports DIN rail mounting on TH35-15 or TH35-7.5 profiles and also allows installation with 2 x M4 or 2 x M6 screws placed diagonally. For quick upgrades, snap it onto standard TH35 rails in control panels and secure with the recommended hardware to ensure reliable voltage and signal integrity in busy automation cabinets.
AC-3 ratings vary by voltage: for 415 V and 440 V at 60 °C it is 40 A, for 690 V it is 25 A, and for 380/400 V it remains 40 A. DC-13 ratings show 24 V up to 6 A (144 W) and progressively lower currents at higher DC voltages, enabling a range of motor and load switching scenarios while maintaining safe disconnects.
Yes. The contactor starter is designed around IEC 60947-4-1 (and related IEC 60947-1) standards, delivering proper isolation, switching performance, and safety margins for conveyor drives and other continuous-motion equipment. Its 3P configuration and 690 V rating align with typical industrial conveyor requirements.
The device carries IEC/EN 60947-1 and IEC/EN 60947-4-1 certifications, UL 60335-2-40 and UL/CSA listings, RoHS and REACH declarations, and CMRT documentation. These certifications help ensure regulatory compliance across global deployments and support safe integration into household appliances and industrial controls.
The unit’s DIN-rail mounting, screw-terminal connections, and compact footprint reduce installation time and panel space. Low per-pole power loss (0.1 W at 6 A, and overall low heat generation) minimizes cooling needs, while broad voltage and current ratings simplify stocking and replacements, delivering lower total cost of ownership and faster project ROI.