ABB 1SBX306321R1122 Contactor Starter - IEC/UL/CSA
Part Number: 1SBX306321R1122
Quick Summary
ABB 1SBX306321R1122 Contactor Starter is a 3-pole motor starter for industrial automation. Engineers often grapple with control gear that hinders panel wiring speed and reliability under peak loads. This device meets IEC/EN 60947-1 and 60947-4-1, UL/CSA listings, and RoHS/REACH declarations, delivering proven safety compliance. Its DIN rail mounting and screw-terminal wiring simplify installation, while the 24–60 V DC control range and 3P main contacts support scalable, energy-efficient control architectures for conveyors, pumps, and processing lines.
Product Information
Extended Description
1SBX306321R1122 ABB: AF80N3R-30-22-11 24-60V50/60HZ 20-60VDC Reversing Contactor
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
140 mm
Product Net Depth / Length
149 mm
Product Net Height
151 mm
Product Net Weight
2.738 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 1000 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Control Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Rated Operational Current AC-1 (Ie)
(1000 V) 60 °C 100 A | (690 V) 40 °C 125 A | (690 V) 70 °C 85 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 80 A | (440 V) 60 °C 80 A | (500 V) 60 °C 65 A | (690 V) 60 °C 49 A | (1000 V) 60 °C 25 A | (380 / 400 V) 60 °C 80 A | (220 / 230 / 240 V) 60 °C 80 A
Rated Operational Current AC-3e (Ie)
(415 V) 60 °C 80 A | (440 V) 60 °C 80 A | (500 V) 60 °C 65 A | (690 V) 60 °C 49 A | (380 / 400 V) 60 °C 80 A | (220 / 230 / 240 V) 60 °C 80 A
Rated Operational Current AC-15 (Ie)
(500 V) 2 A | (690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (400 / 440 V) 3 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (48 V) 2.8 A / 134 W | (72 V) 1 A / 72 W | (110 V) 0.55 A / 60 W | (125 V) 0.55 A / 69 W | (220 V) 0.27 A / 60 W | (250 V) 0.27 A / 68 W | (400 V) 0.15 A / 60 W | (500 V) 0.13 A / 65 W | (600 V) 0.1 A / 60 W
Rated Operational Power AC-3 (Pe)
(415 V) 45 kW | (440 V) 45 kW | (500 V) 45 kW | (690 V) 45 kW | (1000 V) 35 kW | (380 / 400 V) 37 kW | (220 / 230 / 240 V) 22 kW
Rated Operational Power AC-3e (Pe)
(415 V) 45 kW | (440 V) 45 kW | (500 V) 45 kW | (690 V) 45 kW | (380 / 400 V) 37 kW | (220 / 230 / 240 V) 22 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 780 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 140 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1200 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 450 A | for 0.1 s 140 A | for 1 s 100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1150 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 750 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 1000 V | acc. to IEC 60947-5-1 690 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
8 kV
Maximum Electrical Switching Frequency
(AC-15) 1200 cycles per hour | (DC-13) 900 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 24 ... 60 V | 60 Hz 24 ... 60 V | DC Operation 20 ... 60 V
Power Loss
at 6 A per Pole 0.1 W | at Rated Operating Conditions AC-1 per Pole 7.6 W | at Rated Operating Conditions AC-3 per Pole 3 W
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 or 2 x M6 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 6 ... 50 mm² | Flexible with Insulated Ferrule 1/2x 6 ... 50 mm² | Rigid Stranded 1x 6 ... 70 mm² | Rigid Stranded 2x 6 ... 50 mm²
Wire Stripping Length
Auxiliary Circuit 10 mm | Control Circuit 10 mm | Main Circuit 17 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Tightening Torque
Auxiliary Circuit 1.2 N·m | Control Circuit 1.2 N·m | Main Circuit 6 N·m
Terminal Type
Screw Terminals
Product Name
Contactor Starter
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
Connecting Capacity Main Circuit UL/CSA
Rigid Stranded 1/2x 6-1 AWG
Tightening Torque UL/CSA
Auxiliary Circuit 11 in·lb | Control Circuit 11 in·lb | Main Circuit 53 in·lb
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C
Pollution Degree
3
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
A2L Certificate – UL
UL-US Certificate of Compliance AF40 ... AF96 3-pole contactors - UL 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers | UL-CA Certificate of Compliance AF40 ... AF96 3-pole contactors - CSA C22.2 No. 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers
UL Certificate
UL-US-L312527-1141-10303102-9 | UL-CA-L312527-4141-10303102-9
Package Level 1 Units
box 1 piece
Package Level 1 Gross Weight
4.238 kg
Package Level 1 EAN
3471523020436
ETIM 7
EC000010 - Combination of contactors
ETIM 8
EC000010 - Combination of contactors
ETIM 9
EC000010 - Combination of contactors
eClass
V11.0 : 27371003
UNSPSC
39121529
Feature → Business Impact → Application: The 3P main contactor with 3 NO main contacts and 2 NO / 2 NC auxiliary contacts enables reliable motor control and flexible logic for start/stop sequences, reducing wiring complexity and retrofit time in panel assemblies. This translates to lower installation costs and improved mean time between failures in automated production lines. Feature → Business Impact → Application: Rated for auxiliary circuit 690 V and main circuit 1000 V, with AC-3/AC-3e performance, supporting high-demand loads while ensuring equipment protection and energy efficiency in heavy industry applications such as pumps and fans. Feature → Business Impact → Application: Control circuit voltage is 24–60 V DC or 50/60 Hz AC, enabling seamless PLC integration and safer low-voltage control in factory automation environments. Feature → Business Impact → Application: DIN rail TH35-15 mounting and screw-terminal connections plus 1/2 x 6–50 mm² flexible or rigid conductors minimize field wiring errors and speed up commissioning in OEM panel builds. Feature → Business Impact → Application: Power loss and thermal performance (0.1 W per pole; 7.6 W per pole under AC-1) reduce panel heat, supporting compact enclosures in space-constrained installations. Feature → Business Impact → Application: Comprehensive documentation and compatibility (CAD drawings, manuals, RoHS/REACH, ETIM/UNSPSC) streamline procurement, sourcing, and spare-part planning for maintenance teams in industrial facilities.
Get a Quick Quote for a ABB 1SBX306321R1122
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SBX306321R1122?
Enquire Now
FAQs
This unit is designed for mounting on DIN rails per TH35-15 (35 x 15 mm). To install, align the device with the rail, press firmly to engage the clip, and ensure the main terminals are accessible for wiring. Use 2 x M4 or 2 x M6 screws placed diagonally if mounting screws are required. Verify rated terminal torque and wire sizes (1/2 x 6–50 mm²) for reliable connection, then secure the assembly to prevent vibration-induced loosening in industrial environments.
Key ratings include Main Circuit voltage up to 1000 V and Auxiliary Circuit up to 690 V, with rated frequencies of 50/60 Hz. The device supports AC-3 (and AC-3e) operation with currents up to 80 A at various voltages and conditions, and CC/DC control voltages of 24–60 V. Its maximum breaking capacity and short-time withstand currents are specified (Icw values) to ensure safe switching of motor loads under typical industrial duty cycles.
Yes. The product features UL/CSA listings (UL-US and UL-CA certificates) and supports common national and international standards. This, combined with RoHS/REACH compliance and a documented 2D/3D CAD presence, makes it well-suited for UL-listed panel builds in North America and CSA-compliant installations, reducing qualification time and supplier risk for manufacturers.
Mounting on DIN rail with proper screw-terminal connections and correctly torqued terminals (Main Circuit 6 N·m) minimizes connection resistance and arcing. The device features a three-pole design with two auxiliary contacts for interlocking or signaling, and a robust operating range (-40 to 70 °C ambient, IP10 protection for main terminals). This configuration supports dependable motor control with reduced mis-wiring risk in demanding environments.
The product provides CAD dimensional drawings (Information – 2D and 3D files for CAD systems) and a 'Contactor Starter' product name with broader standards coverage. You’ll also find Instructions and Manuals (Part 2) for contactors and overload relays, along with RoHS/REACH declarations and CMRT data to simplify sourcing, BOM preparation, and environmental compliance in global supply chains.