ABB 1SBX306321R1322 Reversing Contactor - IEC/UL/CSA
Part Number: 1SBX306321R1322
Quick Summary
ABB 1SBX306321R1322 reversing contactor delivers reliable motor control for conveyor and process lines in harsh industrial environments. Designers often grapple with compact footprints, wiring complexity, and maintaining control-system compliance as standards evolve. This model aligns with IEC/EN 60947-1 and 60947-4-1, UL 60335-2-40, and CSA C22.2 declarations, supported by RoHS, REACH and TSCA commitments for safer, greener operation. With a DIN rail friendly mount and a versatile control voltage range, it reduces panel space and installation time while delivering robust performance for machines, fans, and conveyors. It is well-suited for applications requiring reliable reversing action and integrated auxiliary signaling.
Product Information
Extended Description
1SBX306321R1322 ABB: AF80N3R-30-22-13 100-250V50/60HZ-DC Reversing Contactor
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
140 mm
Product Net Depth / Length
149 mm
Product Net Height
151 mm
Product Net Weight
2.638 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 1000 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Control Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Rated Operational Current AC-1 (Ie)
(1000 V) 60 °C 100 A | (690 V) 40 °C 125 A | (690 V) 70 °C 85 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 80 A | (440 V) 60 °C 80 A | (500 V) 60 °C 65 A | (690 V) 60 °C 49 A | (1000 V) 60 °C 25 A | (380 / 400 V) 60 °C 80 A | (220 / 230 / 240 V) 60 °C 80 A
Rated Operational Current AC-3e (Ie)
(415 V) 60 °C 80 A | (440 V) 60 °C 80 A | (500 V) 60 °C 65 A | (690 V) 60 °C 49 A | (380 / 400 V) 60 °C 80 A | (220 / 230 / 240 V) 60 °C 80 A
Rated Operational Current AC-15 (Ie)
(500 V) 2 A | (690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (400 / 440 V) 3 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (48 V) 2.8 A / 134 W | (72 V) 1 A / 72 W | (110 V) 0.55 A / 60 W | (125 V) 0.55 A / 69 W | (220 V) 0.27 A / 60 W | (250 V) 0.27 A / 68 W | (400 V) 0.15 A / 60 W | (500 V) 0.13 A / 65 W | (600 V) 0.1 A / 60 W
Rated Operational Power AC-3 (Pe)
(415 V) 45 kW | (440 V) 45 kW | (500 V) 45 kW | (690 V) 45 kW | (1000 V) 35 kW | (380 / 400 V) 37 kW | (220 / 230 / 240 V) 22 kW
Rated Operational Power AC-3e (Pe)
(415 V) 45 kW | (440 V) 45 kW | (500 V) 45 kW | (690 V) 45 kW | (380 / 400 V) 37 kW | (220 / 230 / 240 V) 22 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 780 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 140 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1200 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 450 A | for 0.1 s 140 A | for 1 s 100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1150 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 750 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 1000 V | acc. to IEC 60947-5-1 690 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
8 kV
Maximum Electrical Switching Frequency
(AC-15) 1200 cycles per hour | (DC-13) 900 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 100 ... 250 V | 60 Hz 100 ... 250 V | DC Operation 100 ... 250 V
Power Loss
at 6 A per Pole 0.1 W | at Rated Operating Conditions AC-1 per Pole 7.6 W | at Rated Operating Conditions AC-3 per Pole 3 W
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 or 2 x M6 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 6 ... 50 mm² | Flexible with Insulated Ferrule 1/2x 6 ... 50 mm² | Rigid Stranded 1x 6 ... 70 mm² | Rigid Stranded 2x 6 ... 50 mm²
Wire Stripping Length
Auxiliary Circuit 10 mm | Control Circuit 10 mm | Main Circuit 17 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Tightening Torque
Auxiliary Circuit 1.2 N·m | Control Circuit 1.2 N·m | Main Circuit 6 N·m
Terminal Type
Screw Terminals
Product Name
Contactor Starter
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
Connecting Capacity Main Circuit UL/CSA
Rigid Stranded 1/2x 6-1 AWG
Tightening Torque UL/CSA
Auxiliary Circuit 11 in·lb | Control Circuit 11 in·lb | Main Circuit 53 in·lb
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C
Pollution Degree
3
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
A2L Certificate – UL
UL-US Certificate of Compliance AF40 ... AF96 3-pole contactors - UL 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers | UL-CA Certificate of Compliance AF40 ... AF96 3-pole contactors - CSA C22.2 No. 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers
UL Certificate
UL-US-L312527-1141-10303102-9 | UL-CA-L312527-4141-10303102-9
Package Level 1 Units
box 1 piece
Package Level 1 Gross Weight
4.138 kg
Package Level 1 EAN
3471523020450
ETIM 7
EC000010 - Combination of contactors
ETIM 8
EC000010 - Combination of contactors
ETIM 9
EC000010 - Combination of contactors
eClass
V11.0 : 27371003
UNSPSC
39121529
Three main NO contacts with two NO auxiliary and two NC auxiliary enable reliable three-pole motor control with integrated feedback. This reduces wiring complexity and panel footprint, speeding assembly and maintenance. Ideal for conveyors, packaging lines, and processing equipment where precise motor control and status signals are essential. Control circuit voltage of 100-250 V AC or DC operation simplifies integration with standard plant controls and PLC outputs, reducing wiring errors and accelerating commissioning. High current ratings in AC-3 and AC-3e configurations support common motor loads; for example, 80 A at several voltages enables direct control of medium-sized conveyors or pumps, reducing external contactors and improving energy efficiency. Mounting flexibility includes TH35-15 DIN rail mounting and optional screw mounting, making installation straightforward in existing panels. Terminals are screw-type with ferrule compatibility for robust connections, and power losses remain low (0.1 W per pole at 6 A) to support energy-efficient operation. The compact footprint, combined with a weight of 2.638 kg and dimensions around 140 mm W x 149 mm D x 151 mm H, suits compact control enclosures while delivering dependable long-term performance.
Get a Quick Quote for a ABB 1SBX306321R1322
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SBX306321R1322?
Enquire Now
FAQs
Mount the unit on a TH35-15 DIN rail or use two M4/M6 screws placed diagonally for panel fit. Wire the Main Circuit using flexible ferrule or rigid conductors up to 50 mm² per section, and connect the Auxiliary Circuit per standard control wiring practices. Tighten auxiliary and main terminals to the specified torque, ensuring secure, code-compliant installation with appropriate protective enclosures.
The device supports AC-3 and AC-3e operation with Ie values up to 80 A at various voltages, plus DC-13 ratings for DC control scenarios. Main circuit insulation is rated to 1000 V, with 690 V insulation in lower sections, enabling reliable switching of typical industrial motors. Short-time withstand and breaking capacities ensure protection during startup surges and switching transients.
Yes. The three main normally open contacts plus integrated auxiliary contacts provide reversing control compatible with conveyors, pumps, and similar equipment. The 50/60 Hz rated operation and control voltage range of 100-250 V enable straightforward interface with PLCs and pushbuttons, while DIN rail mounting simplifies panel integration in compact control cabinets.
The product complies with IEC/EN 60947-1 and 60947-4-1, UL 60335-2-40, and CSA C22.2 No. 60335-2-40, with RoHS, REACH and TSCA declarations. It is UL/CSA listed and designed for safe operation in commercial and industrial environments, providing confidence in regulatory compliance and supplier qualification programs.
The design offers low power loss per pole and robust screw-terminal connections, reducing energy consumption and maintenance downtime. Its compact footprint and DIN rail mounting accelerate installation, while integrated auxiliaries improve fault signaling and control reliability. Overall, expect lower lifecycle costs, faster commissioning, and improved uptime for medium-sized motor applications.