ABB 1SBX306321R1422 Reversing Contactor enables reliable motor direction changes in 3-pole drives for packaging lines and conveyors. Engineers often face downtime, space constraints, and wiring complexity when adding reversing functionality to existing panels. This device complies with key standards such as IEC/EN 60947-1 and 60947-4-1, and UL 60335-2-40 with CSA recognition, supporting safe operation in mixed EU/US environments. Its DIN rail mounting compatibility and compact footprint deliver easy installation, reduced panel depth, and straightforward maintenance, while maintaining rigorous electrical protection and control performance for industrial automation applications.
Product Information
Extended Description
1SBX306321R1422 ABB: AF80N3R-30-22-14 250-500V50/60HZ-DC Reversing Contactor
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
140 mm
Product Net Depth / Length
149 mm
Product Net Height
151 mm
Product Net Weight
2.638 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 1000 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Control Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Rated Operational Current AC-1 (Ie)
(1000 V) 60 °C 100 A | (690 V) 40 °C 125 A | (690 V) 70 °C 85 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 80 A | (440 V) 60 °C 80 A | (500 V) 60 °C 65 A | (690 V) 60 °C 49 A | (1000 V) 60 °C 25 A | (380 / 400 V) 60 °C 80 A | (220 / 230 / 240 V) 60 °C 80 A
Rated Operational Current AC-3e (Ie)
(415 V) 60 °C 80 A | (440 V) 60 °C 80 A | (500 V) 60 °C 65 A | (690 V) 60 °C 49 A | (380 / 400 V) 60 °C 80 A | (220 / 230 / 240 V) 60 °C 80 A
Rated Operational Current AC-15 (Ie)
(500 V) 2 A | (690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (400 / 440 V) 3 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (48 V) 2.8 A / 134 W | (72 V) 1 A / 72 W | (110 V) 0.55 A / 60 W | (125 V) 0.55 A / 69 W | (220 V) 0.27 A / 60 W | (250 V) 0.27 A / 68 W | (400 V) 0.15 A / 60 W | (500 V) 0.13 A / 65 W | (600 V) 0.1 A / 60 W
Rated Operational Power AC-3 (Pe)
(415 V) 45 kW | (440 V) 45 kW | (500 V) 45 kW | (690 V) 45 kW | (1000 V) 35 kW | (380 / 400 V) 37 kW | (220 / 230 / 240 V) 22 kW
Rated Operational Power AC-3e (Pe)
(415 V) 45 kW | (440 V) 45 kW | (500 V) 45 kW | (690 V) 45 kW | (380 / 400 V) 37 kW | (220 / 230 / 240 V) 22 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 780 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 140 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1200 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 450 A | for 0.1 s 140 A | for 1 s 100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1150 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 750 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 1000 V | acc. to IEC 60947-5-1 690 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
8 kV
Maximum Electrical Switching Frequency
(AC-15) 1200 cycles per hour | (DC-13) 900 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 250 ... 500 V | 60 Hz 250 ... 500 V | DC Operation 250 ... 500 V
Power Loss
at 6 A per Pole 0.1 W | at Rated Operating Conditions AC-1 per Pole 7.6 W | at Rated Operating Conditions AC-3 per Pole 3 W
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 or 2 x M6 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 6 ... 50 mm² | Flexible with Insulated Ferrule 1/2x 6 ... 50 mm² | Rigid Stranded 1x 6 ... 70 mm² | Rigid Stranded 2x 6 ... 50 mm²
Wire Stripping Length
Auxiliary Circuit 10 mm | Control Circuit 10 mm | Main Circuit 17 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Tightening Torque
Auxiliary Circuit 1.2 N·m | Control Circuit 1.2 N·m | Main Circuit 6 N·m
Terminal Type
Screw Terminals
Product Name
Contactor Starter
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
Connecting Capacity Main Circuit UL/CSA
Rigid Stranded 1/2x 6-1 AWG
Tightening Torque UL/CSA
Auxiliary Circuit 11 in·lb | Control Circuit 11 in·lb | Main Circuit 53 in·lb
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C
Pollution Degree
3
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
A2L Certificate – UL
UL-US Certificate of Compliance AF40 ... AF96 3-pole contactors - UL 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers | UL-CA Certificate of Compliance AF40 ... AF96 3-pole contactors - CSA C22.2 No. 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers
UL Certificate
UL-US-L312527-1141-10303102-9 | UL-CA-L312527-4141-10303102-9
Package Level 1 Units
box 1 piece
Package Level 1 Gross Weight
4.138 kg
Package Level 1 EAN
3471523020467
ETIM 7
EC000010 - Combination of contactors
ETIM 8
EC000010 - Combination of contactors
ETIM 9
EC000010 - Combination of contactors
eClass
V11.0 : 27371003
UNSPSC
39121529
Feature → Business Impact → Application The 3P configuration with 3 NO main contacts and 2 NO/2 NC auxiliary contacts enables flexible motor reversal without additional devices, reducing hardware counts and lifecycle costs in conveyor and packaging lines. Benefit: streamlined control architecture and faster commissioning in automated production lines where direction changes occur regularly. Application: mid-size machinery or line equipment requiring reliable reverse operation with minimal panel space. Feature → Business Impact → Application Rated up to 1000 V main circuit and 690 V auxiliary circuit with 50/60 Hz operation, providing broad compatibility across drives and machines. Benefit: one part fits multiple power levels, lowering spare part stock and simplifying procurement. Application: mixed-voltage motor control in manufacturing cells needing robust performance. Feature → Business Impact → Application DIN rail mounting TH35-15 and screw terminals simplify retrofits and new installs. Benefit: faster, vibration-resistant installations with standardized mounting, reducing installation errors. Application: OEM panel builders and maintenance teams ensuring consistent mounting across machines. Feature → Business Impact → Application Flexible connecting capacity for main circuit wiring (1/2x 6–50 mm², 2x 6–50 mm² or 1x 6–70 mm²). Benefit: compatible with diverse cabling practices, enabling tidy, reliable terminations. Application: power cabinet wiring in conveyors and processing lines. Feature → Business Impact → Application Comprehensive compliance (IEC/EN 60947-1, 60947-4-1; UL/CSA). Benefit: lowers regulatory risk and accelerates customer audits. Application: safety-critical installations in international plants. Feature → Business Impact → Application Compact dimensions and weight (140 mm W x 149 mm D x 151 mm H; ~2.64 kg). Benefit: saves panel space and enables denser control layouts. Application: compact machine enclosures and retrofit projects needing efficient space use.
Get a Quick Quote for a ABB 1SBX306321R1422
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SBX306321R1422?
Enquire Now
FAQs
This reversing contactor supports DIN rail mounting (TH35-15) and screw mounting options for secure panel installation. The unit has a compact footprint (140 mm W x 149 mm D x 151 mm H) and uses screw terminals for main and auxiliary connections, making retrofits straightforward in existing enclosures and ensuring reliable, vibration-resistant operation.
The device provides 3 main NO contacts and 2 NO/2 NC auxiliary contacts. Main circuit voltage is rated up to 1000 V with auxiliary circuit up to 690 V. It operates at 50/60 Hz, with control circuit voltage in the 250–500 V range, supporting versatile control schemes for 3P reversing applications.
Yes. The 1SBX306321R1422 conforms to UL 60335-2-40 and CSA standards, and carries IEC/EN 60947-1 and 60947-4-1 compliance. It has UL/CSA listings and documented tolerances for cross-border installations, reducing compliance risk for multinational manufacturing facilities.
Ideal for packaging lines, conveyors, and machine tools requiring controlled motor reversal. With 3 poles and 3 NO main contacts plus auxiliary contacts, it supports reversing logic in compact panels, improves changeover reliability, and minimizes downtime during direction changes in automated processes.
Choose DIN rail mounting for quick deployment and standardized layouts, ensure proper cable sizing (1/2x 6–50 mm² or 2x 6–50 mm² depending on routing), and adhere to torque specs (main circuit up to 6 N·m). The unit’s robust ratings and compact form factor reduce panel footprint, wiring complexity, and spare parts inventory, delivering faster commissioning and lower lifecycle costs.