ABB AF26-80-00-13LU Block Contactor - UL/CSA LZGH2 A2L

Part Number: 1SBX405551R1300
Manufacturer
ABB
Part number
1SBX405551R1300

Quick Summary

ABB AF26-80-00-13LU Block Contactor is an 8-pole control device designed for UL lighting and motor control applications. In many panels, wide control voltage swings cause misfiring or energy waste; this AF technology handles 100-250 V AC/DC control and provides built-in surge protection to maintain reliable operation. The product complies with IEC/EN 60947-1 and IEC/EN 60947-4-1, along with UL 60335-2-40 and UL/CSA listings, ensuring safety and regulatory conformity for industrial environments. Mounted easily on DIN rails with screw-terminal connections, it supports add-on auxiliary blocks and a wide range of accessories, delivering compact, scalable control solutions that reduce panel footprint and energy losses while improving overall reliability.

Product Information

Extended Description

1SBX405551R1300 ABB: The AF26-80-00-13LU is a 8-pole - 600 UL contactor set with screw terminals, dedicated for UL lighting applications. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC),managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Instructions and Manuals
Installation instructions AF(C)09...38(Z)(B) Contactors, NF(C)(Z)(B)22...80E Contactor relays and CA4, CAL4, CAT4, CC4, LDC4 Accessories
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
90 mm
Product Net Depth / Length
101 mm
Product Net Height
86 mm
Product Net Weight
0.72 kg
Number of Main Contacts NO
8
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
8P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 508, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-4-1
Rated Operational Voltage
Main Circuit 690 V
Rated Frequency (f)
Control Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 55 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 45 A | (690 V) 60 °C 40 A | (690 V) 70 °C 32 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 21.2 A | (440 V) 60 °C 20 A | (500 V) 60 °C 17.6 A | (690 V) 60 °C 10.5 A | (380 / 400 V) 60 °C 22 A | (220 / 230 / 240 V) 60 °C 23.2 A
Rated Operational Power AC-3 (Pe)
(400 V) 11 kW | (415 V) 11 kW | (440 V) 11 kW | (500 V) 11 kW | (690 V) 9 kW | (220 / 230 / 240 V) 5.5 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 55 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 450 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 690 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 100 ... 250 V | 60 Hz 100 ... 250 V | DC Operation 100 ... 250 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 1.6 W | at Rated Operating Conditions AC-3 per Pole 0.42 W
Operate Time
Between Coil De-energization and NC Contact Closing 13 ... 98 ms | Between Coil De-energization and NO Contact Opening 11 ... 95 ms | Between Coil Energization and NC Contact Opening 38 ... 90 ms | Between Coil Energization and NO Contact Closing 40 ... 95 ms
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 1.5 ... 16 mm² | Flexible with Insulated Ferrule 1/2x 1.5 ... 16 mm² | Rigid Solid 1/2x 1.5 ... 4 mm² | Rigid Stranded 1/2x 1.5 ... 16 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid Solid 1/2x 1 ... 2.5 mm² | Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Control Circuit 10 mm | Main Circuit 12 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Control Circuit 1.2 N·m | Main Circuit 2.5 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 45 A
Connecting Capacity Main Circuit UL/CSA
Rigid Solid 1/2x 16-10 AWG | Rigid Stranded 1/2x 16-6 AWG
Connecting Capacity Control Circuit UL/CSA
Rigid Solid 1/2x 18-14 AWG | Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA
Control Circuit 11 in·lb | Main Circuit 22 in·lb
Ambient Air Temperature
Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Closed, Shock Direction: B1 25 g | Open, Shock Direction: B1 5 g | Shock Direction: A 30 g | Shock Direction: B2 15 g | Shock Direction: C1 25 g | Shock Direction: C2 25 g
Resistance to Vibrations
4g Closed Position & 2g Open position 5 ... 300 Hz
Pollution Degree
3
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
A2L Certificate – UL
UL-US A2L LZGH2 Certificate of Compliance AF09 ... AF38 3-pole contactors with screw terminals - UL 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers | UL-CA A2L LZGH2 Certificate of Compliance AF09 ... AF38 3-pole contactors with screw terminals - CSA C22.2 No. 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers
CB Certificate
CB Certificate AF(C)26, AF(C)38, AF26(Z)B, AF38(Z)B 4-pole contactors
Declaration of Conformity - CE
EU Declaration of Conformity AF09..LU ... AF80..LU 3 and 4-pole contactors
Declaration of Conformity - UKCA
UK Declaration of Conformity AF09..LU ... AF80..LU 3 and 4-pole contactors
UL Certificate
UL_20180227_E312527_7_1
Package Level 1 Units
box 1 piece
Package Level 1 Width
87 mm
Package Level 1 Depth / Length
103 mm
Package Level 1 Height
92 mm
Package Level 1 Gross Weight
0.72 kg
Package Level 1 EAN
3471523020894
Package Level 3 Units
864 piece
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
Feature: Wide control voltage range of 100–250 V AC/50/60 Hz and DC control. Business Impact: Reduces panel inventory and simplifies installation across systems with variable control voltages. Application: Lighting and general-purpose control in manufacturing floors where supply fluctuations are common. Feature: Built-in surge protection and compact AF block design. Business Impact: Enhances protection of control circuits and minimizes peripheral surge suppressors, lowering total cost of ownership. Application: Panels in areas with unstable networks or motors starting under load. Feature: 8 NO main contacts (8P) rated up to 690 V main circuit with defined AC-1 and AC-3 currents. Business Impact: Supports higher power switching with predictable life, reducing maintenance and downtime. Application: Motor starters and high-load switching in conveyors and presses. Feature: Low power loss per pole (AC-1 1.6 W; AC-3 0.42 W). Business Impact: Decreases heat generation and energy consumption in control panels, improving efficiency. Application: Continuous operation in enclosed panel environments. Feature: DIN rail mounting TH35-15 or TH35-7.5 and screw-terminal connections. Business Impact: Quick installation, flexible mounting, and straightforward field wiring. Application: New builds and retrofit projects in factory automation. Feature: Expandability with auxiliary contact blocks and accessories. Business Impact: Enables tailored control logic and future-proofed configurations without replacing the base device. Application: Customizable interlocking, signaling, and safety circuits in complex control systems.

Get a Quick Quote for a ABB 1SBX405551R1300

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBX405551R1300? Enquire Now

FAQs

The AF26-80-00-13LU supports DIN rail mounting on TH35-15 or TH35-7.5 rails and can be mounted with 2 x M4 screws placed diagonally if required. This flexibility enables quick panel integration and compatible wiring schemes for compact control cabinets.
Rated Operational Current AC-1 at 690 V is 45 A at 40 °C, 40 A at 60 °C, and 32 A at 70 °C. For AC-3, at 415–690 V ranges, currents vary (e.g., up to 23.2 A at 220–240 V). Insulation and impulse withstand are 690 V and 6 kV respectively, supporting reliable motor control and switching.
Yes. It is designed for UL lighting and motor control applications and carries UL/CSA listings with CE/UKCA declarations. The device supports add-on auxiliary blocks, wide control voltage ranges, and is compatible with standard automation panels, ensuring dependable operation in lighting and motor-start circuits.
Key standards include IEC 60947-1 and IEC 60947-4-1, UL 60335-2-40, UL 508, CSA C22.2 No. 60335-2-40, and CSA C22.2 No. 60947-4-1. It also carries CB certification and CE/UKCA declarations, with RoHS and WEEE compliance for modern panel manufacturing.
Low coil power (1.6 W AC-1 per pole and 0.42 W AC-3 per pole) reduces heat and energy use. Built-in surge protection lowers external suppressor needs, and modular add-on blocks simplify customization without replacing the base unit, cutting maintenance time and inventory while improving system uptime.