ABB 1SBX407551R1300 Block Contactor - UL/CSA 690V

Part Number: 1SBX407551R1300
Manufacturer
ABB
Part number
1SBX407551R1300

Quick Summary

ABB 1SBX407551R1300 Block Contactor is an 8-pole control device designed for UL lighting and motor-control applications. It addresses panel-energy variability by offering a wide control voltage range of 100-250 V (AC) and DC operation, stabilizing startup and reducing energy waste in fluctuating networks. The device meets key certifications including IEC/EN 60947-1, IEC/EN 60947-4-1, and UL/CSA 60335-2-40, providing reliable compliance for global installations. With built-in surge protection and a compact block design, it streamlines panel layouts and maintenance. Compatible with add-on auxiliary contact blocks and various accessories, it supports scalable control architectures while delivering measurable improvements in efficiency and reliability for industrial automation projects.

Product Information

Extended Description

1SBX407551R1300 ABB: The AF38-80-00-13LU is a 8-pole - 600 UL contactor set with screw terminals, dedicated for UL lighting applications. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC),managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Instructions and Manuals
Installation instructions AF(C)09...38(Z)(B) Contactors, NF(C)(Z)(B)22...80E Contactor relays and CA4, CAL4, CAT4, CC4, LDC4 Accessories
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
90 mm
Product Net Depth / Length
101 mm
Product Net Height
86 mm
Product Net Weight
0.72 kg
Number of Main Contacts NO
8
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
8P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 508, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-4-1
Rated Operational Voltage
Main Circuit 690 V
Rated Frequency (f)
Control Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 55 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 55 A | (690 V) 60 °C 45 A | (690 V) 70 °C 37 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 21.2 A | (440 V) 60 °C 20 A | (500 V) 60 °C 17.6 A | (690 V) 60 °C 10.5 A | (380 / 400 V) 60 °C 22 A | (220 / 230 / 240 V) 60 °C 23.2 A
Rated Operational Power AC-3 (Pe)
(400 V) 11 kW | (415 V) 11 kW | (440 V) 11 kW | (500 V) 11 kW | (690 V) 9 kW | (220 / 230 / 240 V) 5.5 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 55 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 450 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 690 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 100 ... 250 V | 60 Hz 100 ... 250 V | DC Operation 100 ... 250 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 2.3 W | at Rated Operating Conditions AC-3 per Pole 0.42 W
Operate Time
Between Coil De-energization and NC Contact Closing 13 ... 98 ms | Between Coil De-energization and NO Contact Opening 11 ... 95 ms | Between Coil Energization and NC Contact Opening 38 ... 90 ms | Between Coil Energization and NO Contact Closing 40 ... 95 ms
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 1.5 ... 16 mm² | Flexible with Insulated Ferrule 1/2x 1.5 ... 16 mm² | Rigid Solid 1/2x 1.5 ... 4 mm² | Rigid Stranded 1/2x 1.5 ... 16 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid Solid 1/2x 1 ... 2.5 mm² | Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Control Circuit 10 mm | Main Circuit 12 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Control Circuit 1.2 N·m | Main Circuit 2.5 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 55 A
Connecting Capacity Main Circuit UL/CSA
Rigid Solid 1/2x 16-10 AWG | Rigid Stranded 1/2x 16-6 AWG
Connecting Capacity Control Circuit UL/CSA
Rigid Solid 1/2x 18-14 AWG | Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA
Control Circuit 11 in·lb | Main Circuit 22 in·lb
Ambient Air Temperature
Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Closed, Shock Direction: B1 25 g | Open, Shock Direction: B1 5 g | Shock Direction: A 30 g | Shock Direction: B2 15 g | Shock Direction: C1 25 g | Shock Direction: C2 25 g
Resistance to Vibrations
4g Closed Position & 2g Open position 5 ... 300 Hz
Pollution Degree
3
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
A2L Certificate – UL
UL-US A2L LZGH2 Certificate of Compliance AF09 ... AF38 3-pole contactors with screw terminals - UL 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers | UL-CA A2L LZGH2 Certificate of Compliance AF09 ... AF38 3-pole contactors with screw terminals - CSA C22.2 No. 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers
CB Certificate
CB Certificate AF(C)26, AF(C)38, AF26(Z)B, AF38(Z)B 4-pole contactors
Declaration of Conformity - CE
EU Declaration of Conformity AF09..LU ... AF80..LU 3 and 4-pole contactors
Declaration of Conformity - UKCA
UK Declaration of Conformity AF09..LU ... AF80..LU 3 and 4-pole contactors
UL Certificate
UL_20180227_E312527_7_1
Package Level 1 Units
box 1 piece
Package Level 1 Width
87 mm
Package Level 1 Depth / Length
103 mm
Package Level 1 Height
92 mm
Package Level 1 Gross Weight
0.72 kg
Package Level 1 EAN
3471523020931
Package Level 3 Units
864 piece
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
Feature → Business Impact → Application: The AF-based wide control voltage range (100-250 V) minimizes the need for multiple coil variants, reducing wiring and inventory while stabilizing operation across unstable networks; this translates to lower panel energy consumption and fewer nuisance trips in lighting and motor-control panels. Feature → Business Impact → Application: Built-in surge protection protects costly loads and power electronics from voltage spikes, improving uptime and extending component life in manufacturing lines and processing facilities. Feature → Business Impact → Application: 8 NO main contacts in an 8P design deliver robust switching for high-load lighting and motor circuits, enabling compact DIN-rail installations (TH35-15 or TH35-7.5) with screw-terminals for secure connections. Feature → Business Impact → Application: Rated for 690 V main circuit with versatile wiring capacities and clear torque specs, supporting reliable field terminations and straightforward commissioning in control cabinets. Feature → Business Impact → Application: Compatibility with add-on auxiliary contact blocks and a wide accessories ecosystem reduces total-cost-of-ownership by enabling future expansion without replacing the base unit. Feature → Business Impact → Application: Compliance with IEC/EN 60947-1, IEC/EN 60947-4-1, UL/CSA standards provides risk-aligned, audit-ready documentation for manufacturing, automotive, and process industries. Feature → Business Impact → Application: DIN-rail mounting, screw-terminal connections, and explicit wire-stripping guides simplify installation, cut labor time, and improve field service efficiency in panel-building projects. Feature → Business Impact → Application: The device’s compact weight (0.72 kg) and modular form factor support space-constrained enclosures while maintaining robust thermal performance under 40–70 °C operating conditions.

Get a Quick Quote for a ABB 1SBX407551R1300

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBX407551R1300? Enquire Now

FAQs

This cont actor supports DIN rail mounting on TH35-15 or TH35-7.5 rails and can be screwed to panels using 2 x M4 screws (not supplied). The screw-terminal design simplifies field wiring, and the unit is compatible with add-on auxiliary contact blocks for scalable control. For retrofit projects, ensure mounting space and rail size meet the 90 mm width and 101 mm depth specifications.
Key specs include 8 main NO contacts (8P), rated main-circuit voltage up to 690 V, control voltage 100-250 V (AC 50/60 Hz) or DC, and 55 A IEC 60947-4-1 current at 40 °C (AC-1) with derating at higher temperatures. Power loss is 2.3 W per pole (AC-1) and 0.42 W per pole (AC-3). It supports up to 300 A short-time withstand current and 6 kV impulse withstand voltage.
Yes. The AF38-80-00-13LU design targets UL lighting control with an 8-pole configuration and wide control range, ensuring stable operation under voltage fluctuations. Its IEC/EN 60947-1 and 60947-4-1 certifications, along with UL/CSA approvals, make it appropriate for lighting and motor-control panels in commercial and industrial environments, including spaces with variable power quality.
This model carries IEC/EN 60947-1, IEC/EN 60947-4-1 conformity, UL 60335-2-40 family approvals, and CSA equivalents. It also meets UL 508, and CSA C22.2 standards for related equipment. UKCA and CE declarations are available, along with RoHS/REACH declarations, enabling compliance in global manufacturing and equipment safety audits.
The wide control voltage tolerance reduces the need for multiple coil variants, lowering inventory and wiring complexity, which shortens commissioning time. Built-in surge protection mitigates surge-related faults, reducing maintenance and replacement costs. Expandability with auxiliary blocks minimizes future upgrades, improving total cost of ownership while maintaining reliable operation in UL lighting and motor-control panels.