ABB 1SBX407651R1300 Contactor - UL 60335-2-40 LZGH2 A2L

Part Number: 1SBX407651R1300
Manufacturer
ABB
Part number
1SBX407651R1300

Quick Summary

ABB 1SBX407651R1300 Contactor is a robust motor control device for UL lighting and industrial circuits. In networks with fluctuating control voltages, performance can degrade and energy waste rises. It carries IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, and CB/CE/UKCA markings to ensure global compliance for machinery and panel builders. Designed for DIN rail TH35-15 or TH35-7.5 mounting, it is easily integrated with add-on auxiliary contact blocks and a wide range of accessories, enabling scalable control schemes. This combination delivers reliable operation, reduces panel complexity, and supports lifecycle cost reduction in demanding environments.

Product Information

Extended Description

1SBX407651R1300 ABB: The AF38-120-00-13LU is a 12-pole - 600 UL contactor set with screw terminals, dedicated for UL lighting applications. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC),managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Instructions and Manuals
Installation instructions AF(C)09...38(Z)(B) Contactors, NF(C)(Z)(B)22...80E Contactor relays and CA4, CAL4, CAT4, CC4, LDC4 Accessories
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
135 mm
Product Net Depth / Length
101 mm
Product Net Height
86 mm
Product Net Weight
1.08 kg
Number of Main Contacts NO
12
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
12P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 508, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-4-1
Rated Operational Voltage
Main Circuit 690 V
Rated Frequency (f)
Control Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 55 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 55 A | (690 V) 60 °C 45 A | (690 V) 70 °C 37 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 21.2 A | (440 V) 60 °C 20 A | (500 V) 60 °C 17.6 A | (690 V) 60 °C 10.5 A | (380 / 400 V) 60 °C 22 A | (220 / 230 / 240 V) 60 °C 23.2 A
Rated Operational Power AC-3 (Pe)
(400 V) 11 kW | (415 V) 11 kW | (440 V) 11 kW | (500 V) 11 kW | (690 V) 9 kW | (220 / 230 / 240 V) 5.5 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 55 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 450 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 690 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 100 ... 250 V | 60 Hz 100 ... 250 V | DC Operation 100 ... 250 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 2.3 W | at Rated Operating Conditions AC-3 per Pole 0.42 W
Operate Time
Between Coil De-energization and NC Contact Closing 13 ... 98 ms | Between Coil De-energization and NO Contact Opening 11 ... 95 ms | Between Coil Energization and NC Contact Opening 38 ... 90 ms | Between Coil Energization and NO Contact Closing 40 ... 95 ms
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 1.5 ... 16 mm² | Flexible with Insulated Ferrule 1/2x 1.5 ... 16 mm² | Rigid Solid 1/2x 1.5 ... 4 mm² | Rigid Stranded 1/2x 1.5 ... 16 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid Solid 1/2x 1 ... 2.5 mm² | Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Control Circuit 10 mm | Main Circuit 12 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Control Circuit 1.2 N·m | Main Circuit 2.5 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 55 A
Connecting Capacity Main Circuit UL/CSA
Rigid Solid 1/2x 16-10 AWG | Rigid Stranded 1/2x 16-6 AWG
Connecting Capacity Control Circuit UL/CSA
Rigid Solid 1/2x 18-14 AWG | Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA
Control Circuit 11 in·lb | Main Circuit 22 in·lb
Ambient Air Temperature
Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Closed, Shock Direction: B1 25 g | Open, Shock Direction: B1 5 g | Shock Direction: A 30 g | Shock Direction: B2 15 g | Shock Direction: C1 25 g | Shock Direction: C2 25 g
Resistance to Vibrations
4g Closed Position & 2g Open position 5 ... 300 Hz
Pollution Degree
3
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
A2L Certificate – UL
UL-US A2L LZGH2 Certificate of Compliance AF09 ... AF38 3-pole contactors with screw terminals - UL 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers | UL-CA A2L LZGH2 Certificate of Compliance AF09 ... AF38 3-pole contactors with screw terminals - CSA C22.2 No. 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers
CB Certificate
CB Certificate AF(C)26, AF(C)38, AF26(Z)B, AF38(Z)B 4-pole contactors
Declaration of Conformity - CE
EU Declaration of Conformity AF09..LU ... AF80..LU 3 and 4-pole contactors
Declaration of Conformity - UKCA
UK Declaration of Conformity AF09..LU ... AF80..LU 3 and 4-pole contactors
UL Certificate
UL_20180227_E312527_7_1
Package Level 1 Units
box 1 piece
Package Level 1 Width
87 mm
Package Level 1 Depth / Length
103 mm
Package Level 1 Height
137 mm
Package Level 1 Gross Weight
1.08 kg
Package Level 1 EAN
3471523020955
Package Level 3 Units
864 piece
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
Feature: Wide control voltage range 100–250 V AC, 60 Hz or 50 Hz and DC operation. Business impact: Enables stable coil performance amid supply variations, reducing nuisance trips and energy waste in lighting and motor control. Application: Ideal for UL lighting applications and mixed-control networks where voltage fluctuates. Feature: 12-pole, 12 NO main contacts with screw terminals. Business impact: Increases switching capacity and simplifies wiring; supports higher load with a single device, lowering panel footprint and wiring errors. Application: Large lighting banks, conveyors, and machine controls requiring multiple NO paths. Feature: Built-in surge protection and AF technology for extended reliability. Business impact: Minimizes peak transients, extends contact life, and lowers maintenance costs in harsh electrical environments. Application: OEM machinery, HVAC systems, and production lines. Feature: Comprehensive ratings for AC-1 and AC-3 operation with clear current values. Business impact: Enables precise selection for motor start/stop duties and prevents overdimensioning, saving capex. Application: Electric motors and resistive inductive loads across 220–690 V. Feature: DIN rail mounting and compatible with accessory blocks. Business impact: Simplifies installation, future expansion, and serviceability in control panels. Application: Control cabinets with TH35 mounting rails and add-on modules. Feature: Robust mechanical and electrical specifications (IP20, 6 kV Uimp, 690 V Ui). Business impact: Ensures safe operation and regulatory compliance in industrial environments. Application: Panel-mounted contactors in manufacturing and processing facilities. Feature: UL/CSA, CE/UKCA declarations and CB certificates. Business impact: Reduces vendor risk and streamlines certification processes, supporting global deployments. Application: Global product rollouts and cross-border projects.

Get a Quick Quote for a ABB 1SBX407651R1300

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBX407651R1300? Enquire Now

FAQs

The 1SBX407651R1300 Contactor is designed for DIN rail mounting on TH35-15 or TH35-7.5 profiles, enabling quick installation in control cabinets. It also supports mounting by screws if needed, with diagonal 2x M4 screws. This flexibility simplifies retrofits and new panel builds while maintaining a tidy, organized wiring layout.
The coil operates from 100 to 250 V, supporting 50/60 Hz AC and DC operation. This wide range accommodates voltage variations common in industrial networks, reducing control voltage sensitivity and improving reliability in fluctuating power conditions.
The contactor provides 12 NO main contacts (12P) with ratings suitable for AC-3, including 21.2 A at 415 V to 23.2 A at 240 V and 10.5–11 kW power depending on voltage. This makes it well-suited for starting and switching inductive loads, offloading heavy loads from smaller devices and reducing panel clutter.
Compliance includes IEC/EN 60947-1 and 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL/CSA general use ratings, CB certificates, CE and UKCA declarations. The UL certificate number is UL_20180227_E312527_7_1. These certifications support global usage in machinery, HVAC, and home appliance safety applications.
Typical applications include UL lighting circuits, HVAC, conveyors, and industrial machinery requiring high-pole, high-current control. Benefits include reduced energy consumption due to wide control voltage tolerance, lower maintenance thanks to surge protection, and easier expansion with add-on auxiliary blocks. The result is faster panel assembly, fewer parts, and a lower total cost of ownership over the device lifecycle.