ABB 1SCD014082R1 Contactor - 3P 240V UL1008
Part Number: 1SCD014082R1
Quick Summary
ABB 1SCD014082R1 Contactor is a high-current 3P switch for 220–240 V AC motors. Engineers face reliability, arcing, and footprint challenges in compact control panels. This unit carries UL1008 and cULus certifications and aligns with CMRT reporting for responsible sourcing. With a 600 A rating and open-transition action, it delivers fast, safe motor switching in demanding environments. Made in the United States, it integrates with standard wiring diagrams and common installation practices, supporting efficient installation and predictable procurement. Ideal for industrial automation and electrical protection & circuit control applications, it aligns with industry standards while delivering robust control, simplifying maintenance, and reducing lifecycle costs.
Product Information
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Instructions and Manuals
ZTGSE and ZTSSE Operation & Maintenance Manual
Wiring Diagram
77A-2005 ZTGSE 30-1200A Electrical Schematic
Minimum Order Quantity
1 piece
Customs Tariff Number
853710
Country of Origin
United States (US)
Package Level 1 Units
crate 1 piece
Controller Type
CG (Level 3)
Neutral Type
No Neutral
Number of Poles
3P
Rated Frequency (f)
Main Circuit 50/60 Hz
Rated Operational Voltage
220 ... 240 V AC
Standards
UL1008
Transition Type
Open Transition
Ampere Rating
600 A
UL Certificate
cULus - CERTIFICATE OF COMPLIANCE - E35022-Vol1-Sec1-20230616
ETIM 8
EC000066 - Power contactor, AC switching
WEEE Category
4. Large Equipment (Any External Dimension More Than 50 cm)
Feature: High-current 600 A rating for a 3P contactor; Business Impact: enables reliable control of large motor loads with minimized downtime; Application: conveyors, pumps, and heavy-duty industrial equipment in process lines. Feature → Business Impact → Application. Feature: Open Transition switching; Business Impact: reduces arcing and extends contact life, improving panel safety and maintenance intervals; Application: start/stop sequences in demanding motors. Feature: UL1008 and cULus certifications; Business Impact: simplifies regulatory compliance and supplier qualification; Application: US-based facilities and regulated industries seeking robust electrical protection. Feature: No Neutral design; Business Impact: lowers panel wiring complexity and saves space without sacrificing performance; Application: standard 3P control panels in automation lines. Feature: CMRT compliance and WEEE categorization; Business Impact: enhances supply-chain transparency and sustainability reporting; Application: procurement for OEMs and sustainability-focused projects. Feature: US-origin manufacturing; Business Impact: supports local supply chains and shorter lead times; Application: onsite builds and regulated manufacturing environments.
Get a Quick Quote for a ABB 1SCD014082R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SCD014082R1?
Enquire Now
FAQs
Yes. The 1SCD014082R1 is a three-pole (3P) contactor designed for 220–240 V AC operation, commonly used in standard industrial control panels and with typical 3P wiring schemes. Its 600 A rating supports heavy motor loads, while the open-transition action helps with arc control during switching. When selecting mounting and busbar hardware, verify panel space and conductor sizing to ensure clean, reliable integration.
The device is specified for main circuit operation at 50/60 Hz, with a 220–240 V AC supply and a 600 A ampere rating. This aligns with typical industrial motors and pumps. Designers should plan for proper conductor sizing and thermal management to sustain peak current during inrush and steady-state operation without overheating, ensuring long-term reliability in continuous-duty applications.
Key certifications include UL1008 and cULus, providing recognized safety compliance for electrical protection and circuit control. The CMRT template supports responsible sourcing reporting, and WEEE categorization indicates suitability for large equipment recycling. Documenting these certifications in RFQs and PO specs helps reduce supplier risk and ensures regulatory alignment for US and global projects.
Yes. The 600 A rating supports robust motor switching with Open Transition to mitigate arc formation, reducing wear on contacts and extending service intervals. UL/cUL compliance minimizes rework during audits, and CMRT/WEEE transparency helps with sustainability reporting. Together, these factors translate into lower maintenance costs, fewer unscheduled outages, and more predictable downtime planning.
Wiring diagrams and operation manuals referenced for this model include the 77A-2005 ZTGSE 30-1200A Electrical Schematic and the ZTGSE/ZTSSE Operation & Maintenance Manual. These resources support correct wiring, safe installation, and ongoing maintenance. When planning installation, consult the official schematics to confirm contactor terminations, coil voltage, and the appropriate transition type for open-transition switching.