ABB 1SCD014118R1 CGSE OT 600A 3P 415V - UL 1008

Part Number: 1SCD014118R1
Manufacturer
ABB
Part number
1SCD014118R1

Quick Summary

ABB 1SCD014118R1 is a CGSE OT circuit protection device designed for 380–415 V AC three-phase systems up to 600 A. Engineers often struggle with reliable protection during startup and Open Transition events, which can disrupt production and shorten equipment life. This unit carries UL 1008 certification with a formal cULus certificate and aligns with ETIM EC000066 classification, supporting compliant electrical installations and responsible lifecycle handling (WEEE category 4). In addition, the 50/60 Hz compatibility and solid neutral bar simplify panel wiring and protection coordination, delivering business value through safer operations and faster commissioning in industrial automation environments.

Product Information

Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Instructions and Manuals
ZTGSE and ZTSSE Operation & Maintenance Manual
Wiring Diagram
77A-2005 ZTGSE 30-1200A Electrical Schematic
Minimum Order Quantity
1 piece
Customs Tariff Number
853710
Country of Origin
United States (US)
Package Level 1 Units
crate 1 piece
Controller Type
CG (Level 3)
Neutral Type
Solid Neutral Bar
Number of Poles
3P
Rated Frequency (f)
Main Circuit 50/60 Hz
Rated Operational Voltage
380 ... 415 V AC
Standards
UL1008
Transition Type
Open Transition
Ampere Rating
600 A
UL Certificate
cULus - CERTIFICATE OF COMPLIANCE - E35022-Vol1-Sec1-20230616
ETIM 8
EC000066 - Power contactor, AC switching
WEEE Category
4. Large Equipment (Any External Dimension More Than 50 cm)
High current capability and a compact CGSE OT design enable safe switching of heavy loads up to 600 A, reducing the number of protective devices in a panel and cutting installation time. This translates to lower upfront costs and simpler panel layouts for feeders and distribution sections in manufacturing environments. Rated for 380–415 V AC and 50/60 Hz, it fits regional power architectures without requiring custom solutions, minimizing engineering risk and accelerating time-to-production. Open Transition switching minimizes arcing and wear on contacts, contributing to longer service life and reduced maintenance downtime in conveyors and packaging lines. The solid neutral bar simplifies wiring practices and improves protection coordination across 3P4W configurations, enabling robust fault isolation and faster fault diagnosis in control panels. UL 1008 compliance and cULus recognition provide regulatory alignment, reducing project risk and speeding NEC and local code approvals. Supplementary resources, including CMRT, operation manuals, and wiring diagrams, support procurement, installation, and ongoing maintenance.

Get a Quick Quote for a ABB 1SCD014118R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SCD014118R1? Enquire Now

FAQs

Installation should begin with verifying 380–415 V AC supply availability and ensuring a three-pole, four-wire configuration. Mount the unit per standard enclosure guidelines, connect lines to the phase terminals and the neutral bar, and tie into the protective circuit according to the 3P open-transition operation. Use the included wiring diagram (77A-2005 ZTGSE) as a reference to align conductors, terminal screws, and ground connections. Ensure correct ACL and short-circuit protection settings, then perform a controlled OCC (operational commissioning) to validate proper isolation during fault conditions. This approach minimizes commissioning time and reduces field wiring errors.
Key specifications include a 600 A ampere rating, three poles (3P), and a rated operational voltage range of 380–415 V AC. The device operates at 50/60 Hz, supports open-transition switching, and features a solid neutral bar for stable neutral reference. It is designed for 3P4W configurations and UL 1008 compliance, ensuring safe, code-aligned operation in industrial power protection scenarios. These specs collectively enable reliable protection of heavy-duty feeders and motors in demanding environments.
Yes. The unit is specified for 50/60 Hz operation, making it suitable for both North American and international power systems. Country of origin is the United States (US), and the product carries a UL certificate (UL 1008) with a cULus designation, supporting compliance within US-based electrical panels and NEC-adjacent installations. When integrating into a US-based panel, confirm local code requirements and ensure the 380–415 V AC range matches the system voltage.
The device carries UL 1008 as a primary standard, along with a formal cULus certificate, indicating compliance with North American electrical safety requirements. It is classified under ETIM EC000066 for power contactors, AC switching, and WEEE category 4 for equipment retirement. These certifications support safety, regulatory acceptance, and responsible end-of-life handling in industrial facilities and procurement specifications.
The 600 A, 3P open-transition protection supports reliable startup and fault isolation for large feeders and motors, reducing unplanned downtime and extending equipment life. UL 1008 compliance eases permitting and code adherence, while the solid neutral bar simplifies wiring and improves protection coordination. Availability of manuals and wiring diagrams speeds maintenance, and CMRT alignment helps with supply-chain transparency and responsible sourcing in modern industrial operations.