ABB 1SCD014153R1 CGSE OT 400A is a high‑reliability power switch for motor control and distribution. This device helps prevent downtime and mis-wiring in critical circuits by delivering clear, UL‑listed protection. It carries UL 1008 certification, cULus compliance, and ETIM EC000066 alignment to support consistent, regulated classification. In practice, it integrates smoothly into electrical protection and circuit control workflows, supporting open transition and switched neutral configurations for 208 V systems to improve installation efficiency and safety. Developers and maintenance teams will appreciate the clear wiring diagrams and CMRT compliance documentation that simplify procurement and audits. Suitable for switchgear, MCCs, and pump stations, it reduces integration risk and accelerates project timelines.

Product Information

Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Instructions and Manuals
ZTGSE and ZTSSE Operation & Maintenance Manual
Wiring Diagram
77A-2005 ZTGSE 30-1200A Electrical Schematic
Minimum Order Quantity
1 piece
Customs Tariff Number
853710
Country of Origin
United States (US)
Package Level 1 Units
crate 1 piece
Controller Type
CG (Level 3)
Neutral Type
Switched Neutral
Number of Poles
4P
Rated Frequency (f)
Main Circuit 50/60 Hz
Rated Operational Voltage
208 V AC
Standards
UL1008
Transition Type
Open Transition
Ampere Rating
400 A
UL Certificate
cULus - CERTIFICATE OF COMPLIANCE - E35022-Vol1-Sec1-20230616
ETIM 8
EC000066 - Power contactor, AC switching
WEEE Category
4. Large Equipment (Any External Dimension More Than 50 cm)
Feature: 400 A Ampere rating enables reliable high-current switching for demanding MCC loads. Business Impact: reduces the need for multiple devices in parallel, lowering cabinet footprint and wiring complexity while improving overall system reliability. Application: ideal as the main contactor in 208 V AC, 3P4W motor control centers where consistent switching is required. Feature: 4P configuration supports full four-pole switching on 208 V 3P4W systems. Business Impact: ensures complete isolation of all poles, minimizes arcing, and enhances safety during transitions. Application: power distribution panels and switchgear in manufacturing and processing facilities. Feature: Open Transition and Switched Neutral capabilities provide controlled energizing and safe neutral switching. Business Impact: reduces arc flash risk and enables sequencing strategies for critical loads. Application: motor starters and circuits where neutral switching is necessary for diagnostics or fault isolation. Feature: UL 1008 compliance and cULus certification establish regulatory acceptance and audit readiness. Business Impact: mitigates compliance risk, simplifies supplier qualification, and accelerates project approvals. Application: North American electrical protection and circuit control installations in protected environments. Feature: CMRT compliance plus accessible Wiring Diagram and Operation & Maintenance Manual support responsible sourcing and fast commissioning. Business Impact: improves procurement transparency, supports audits, and reduces downtime during start-up. Application: enterprise supply chains and service teams managing large MCC deployments.

Get a Quick Quote for a ABB 1SCD014153R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SCD014153R1? Enquire Now

FAQs

To install, mount the 4P contactor in a compliant enclosure and connect three phase lines to the L1–L3 terminals with the fourth pole for the neutral as required by the switched neutral configuration. Verify wiring against the 77A‑2005 ZTGSE schematic, use the open transition setting, and ensure the CMRT documentation is available for procurement traceability. Follow local electrical codes and UL 1008 requirements during commissioning.
The 400 A ampere rating supports high-current motor control centers without needing parallel devices, reducing cabinet size and wiring complexity. This improves reliability and lowers installation time while providing a safe margin for startup surges typical in heavy‑duty MCC environments.
Yes. The Open Transition feature permits break-before-make switching with reduced arcing, which is beneficial for motor startups and controlled load switching. Switched Neutral further supports diagnostic tests and neutral-referenced control schemes common in 208V systems.
This product carries UL 1008 certification and has cULus compliance, aligning with North American regulations. Additional classifications include ETIM EC000066, ensuring standardized product data across procurement platforms and maintenance documentation.
CMRT compliance supports responsible sourcing, while the wiring diagram and maintenance manual streamline installation and future servicing. Together, they reduce procurement risk, shorten commissioning, and facilitate audits, delivering faster project delivery and lower lifecycle costs.