ABB 1SCD014241R1 CG Contactor - UL 1008, 1200A, 208V

Part Number: 1SCD014241R1
Manufacturer
ABB
Part number
1SCD014241R1

Quick Summary

ABB 1SCD014241R1 is a CG contactor for high-current motor control in industrial equipment. Engineers often face downtime, arcing, and unreliable switching when handling 1200 A loads, so a robust, UL 1008‑certified solution is essential. This device carries UL 1008 certification, cULus listing, and ETIM 8 EC000066 compatibility to support safety compliance and procurement needs. With a solid 3P arrangement and a solid neutral bus, it simplifies panel integration while delivering scalable current handling for automation projects and larger equipment fleets.

Product Information

Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Instructions and Manuals
ZTGSE and ZTSSE Operation & Maintenance Manual
Wiring Diagram
77A-2006 ZTSSE 30-1200A Electrical Schematic
Minimum Order Quantity
1 piece
Customs Tariff Number
853710
Country of Origin
United States (US)
Package Level 1 Units
crate 1 piece
Controller Type
CG (Level 3)
Neutral Type
Solid Neutral Bar
Number of Poles
3P
Rated Frequency (f)
Main Circuit 50/60 Hz
Rated Operational Voltage
208 V AC
Standards
UL1008
Transition Type
Delayed Transition
Ampere Rating
1200 A
UL Certificate
cULus - CERTIFICATE OF COMPLIANCE - E535104-Vol1-Sec1-20230619
ETIM 8
EC000066 - Power contactor, AC switching
WEEE Category
4. Large Equipment (Any External Dimension More Than 50 cm)
Feature CG (Level 3) controller with 3P architecture delivers reliable switching for heavy loads; Business Impact reduced risk of outages and extended component life in harsh industrial environments; Application suitable for high‑duty motor control in pumps, conveyors, and processing lines. Feature Delayed Transition minimizes inrush and mechanical wear at start‑up; Business Impact lowers maintenance costs and extends contactor life in demanding automation scenarios; Application ideal for equipment that requires soft-start behavior during startup sequences. Feature Solid Neutral Bar enhances electrical balance and fault isolation; Business Impact improves safety margins and simplifies wiring in control panels; Application beneficial for installations with stringent neutral integrity requirements in North American facilities. Feature Wiring Diagram 77A‑2006 ZTSSE provides clear installation guidance; Business Impact reduces commissioning time and risk of wiring errors; Application supports efficient retrofits and new builds. Feature UL 1008 certification and cULus listing; Business Impact mitigates compliance risk and accelerates procurement cycles; Application critical for regulated industries and equipment subject to electrical safety standards. Feature Country of Origin United States (US) ensures supply chain transparency; Business Impact supports localization strategies and reduce lead times in North America; Application ideal for domestic manufacturing and regional builds. Feature Minimum Order Quantity 1 piece and Packaging crate 1 piece; Business Impact enables flexible procurement and safe, secure transport; Application suits project‑driven BOM planning and warehouse logistics.

Get a Quick Quote for a ABB 1SCD014241R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SCD014241R1? Enquire Now

FAQs

To install the ABB 1SCD014241R1 in a 3P 208 V system, mount the unit in a suitable enclosure, connect the three phase lines to the main contacts, and attach the solid neutral bar as specified. Refer to the 77A-2006 ZTSSE electrical schematic for wiring guidance, verify the 50/60 Hz compatibility, and ensure UL 1008 compliance during commissioning. Proper torque and clearance are required for reliable operation and heat dissipation.
This model is rated for 1200 A with a main circuit voltage of 208 V AC and handles 50/60 Hz operation. It uses a Delayed Transition type to minimize inrush and mechanical wear, and is designed as a 3P CG (Level 3) controller. The device complies with UL 1008 and carries cULus listing, providing robust protection for high-current motor switching.
Yes. The 1SCD014241R1 is purpose-built for heavy motor control in 208 V systems, with a 1200 A rating and delayed transition to reduce startup stress. Its solid neutral bar simplifies panel wiring, and its UL/cUL certifications support regulatory compliance in industrial conveyors, pumps, and processing lines where reliable switching and safety are paramount.
The device carries UL 1008 certification and cULus listing, plus ETIM 8 EC000066 classification for power contactors. It includes conflict minerals reporting (CMRT) and WEEE category information, ensuring traceability and environmental compliance. Documentation such as operation and maintenance manuals and wiring diagrams are referenced in the product specs to streamline audits and approvals.
The Delayed Transition feature reduces mechanical wear, lowering maintenance frequency and extending service life in demanding applications. A solid neutral bar improves electrical stability, reducing fault incidents. Additionally, UL/cUL compliance and standardized wiring diagrams shorten commissioning time, decreasing total cost of ownership and optimizing uptime for automation projects.