ABB 1SCD014276R1 CGSE DT Contactor - UL1008

Part Number: 1SCD014276R1
Manufacturer
ABB
Part number
1SCD014276R1

Quick Summary

1SCD014276R1 is an ABB CGSE DT 3P 240V contactor for reliable 3‑phase control in industrial electrical protection and circuit control. Engineers often struggle with finding devices that match high current requirements while preserving switch integrity; this part delivers a robust 1000 A rating and a controlled delayed transition to minimize inrush and mechanical wear. Key certifications include UL 1008 compliance with cULus listing and standardized data under ETIM EC000066, along with WEEE categorization to support responsible disposal. By aligning with these standards, ABB helps minimize downtime, simplify compliance reporting, and accelerate procurement through one component that fits existing motor control architectures. The product also integrates into standard packages and offers clear wiring diagrams for installation efficiency and repeatable performance.

Product Information

Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Instructions and Manuals
ZTGSE and ZTSSE Operation & Maintenance Manual
Wiring Diagram
77A-2006 ZTSSE 30-1200A Electrical Schematic
Minimum Order Quantity
1 piece
Customs Tariff Number
853710
Country of Origin
United States (US)
Package Level 1 Units
crate 1 piece
Controller Type
CG (Level 3)
Neutral Type
Solid Neutral Bar
Number of Poles
3P
Rated Frequency (f)
Main Circuit 50/60 Hz
Rated Operational Voltage
220 ... 240 V AC
Standards
UL1008
Transition Type
Delayed Transition
Ampere Rating
1000 A
UL Certificate
cULus - CERTIFICATE OF COMPLIANCE - E535104-Vol1-Sec1-20230619
ETIM 8
EC000066 - Power contactor, AC switching
WEEE Category
4. Large Equipment (Any External Dimension More Than 50 cm)
Feature: 3-pole CGSE DT design delivering 1000 A ampere rating and 220-240 V AC operation. Business Impact: Supports high-demand industrial motors with reliable current handling, reducing overload events and unplanned downtime. Application: Ideal for 3-phase motors and heavy loads in material handling, pumps, and conveyors across manufacturing facilities, where robust switching and safety margins are non-negotiable. Feature: Delayed transition switching to control inrush and arcing. Business Impact: Extends contact life, lowers maintenance costs, and improves starter performance. Application: Start/stop sequences in conveyors, fans, and process lines where soft-start behavior prevents mechanical stress and voltage dips. Feature: Solid neutral bar and 3P configuration for straightforward panel integration. Business Impact: Simplified wiring, safer installation, and better fault isolation. Application: OEM panels and facility switchgear where neat neutral distribution supports reliable operation of auxiliary circuits and safe maintenance intervals. Feature: UL 1008 standard compliance with cULus listing and ETIM classification. Business Impact: Regulatory confidence for procurement, compliance reporting, and reduced risk of certification-related delays. Application: Replacement in critical infrastructure, OEM equipment conforming to North American electrical safety standards and energy-code requirements. Feature: Comprehensive documentation and packaging, including CMRT, O&M manual, wiring diagram, and MOQ of 1 piece. Business Impact: Accelerates sourcing, simplifies installation planning, and minimizes stock-keeping costs. Application: Procurement and maintenance teams needing quick access to instructions such as 'ZTGSE and ZTSSE Operation & Maintenance Manual' and '77A-2006 ZTSSE 30-1200A Electrical Schematic'.

Get a Quick Quote for a ABB 1SCD014276R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SCD014276R1? Enquire Now

FAQs

This 3P 240V AC device is designed for straightforward panel mount in standard control cabinets. Plan for a solid neutral bus, ensure adequate clearance for the delayed transition mechanism, and follow the wiring diagram (77A-2006 ZTSSE) to connect the three phase lines and neutral. Minimum order is one piece, with packaging in a crate for safe shipping. Proper torque and secure lugs are essential to maintain performance across duty cycles.
Delayed transition reduces inrush currents and arcing during switching, which lowers mechanical stress on contacts and extends component life. This improves motor startup reliability in conveyors and pumps and reduces maintenance events. In practice, expect fewer contact wear-related faults and steadier operation during peak load periods, contributing to lower lifecycle costs and reduced downtime.
The unit is designed for 3P 240V systems with a robust 1000 A rating, which suits demanding conveyor and extrusion lines. For harsh environments, verify enclosure protection and ensure proper installation per standards UL1008 requirements. While not specifying an IP rating here, you can combine with appropriate enclosure and shielding to achieve the needed ingress protection for your application.
The device carries UL 1008 compliance with cULus listing and ETIM EC000066 classification, reinforcing safety and interchangeability in North American control panels. This simplifies supplier qualification, audit readiness, and regulatory reporting, facilitating smoother procurement and reducing certification-related delays in OEM and retrofit projects.
The combination of a 1000 A rating, delayed transition, and solid neutral design yields longer component life and improved startup efficiency, translating to lower maintenance costs and reduced downtime. The availability of comprehensive manuals and wiring diagrams accelerates installation and future servicing, delivering faster time-to-value for capital equipment and plant-wide motor control upgrades.