ABB 1SCD014312R1 CGSE DT Contactor - 1000A UL 1008
Part Number: 1SCD014312R1
Quick Summary
ABB 1SCD014312R1 is a CGSE DT contactor for high-current three-phase motor protection. Many switchgear deployments struggle with arcing, reliability, and wiring complexity when interrupting 440-480 V loads at 1000 A. It carries UL 1008 standards compliance and is listed with cULus, while ETIM EC000066 placement supports clear product categorization. This combination delivers safer operation, faster maintenance, and predictable performance for electrical protection and control gear in demanding industrial environments. Designed for US-origin components, it simplifies procurement with clear documentation, including CMRT, maintenance manuals, and a wiring diagram. For engineering teams, this translates to reduced downtime, faster commissioning, and improved compliance across plant electrical protection and control gear ecosystems.
Product Information
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Instructions and Manuals
ZTGSE and ZTSSE Operation & Maintenance Manual
Wiring Diagram
77A-2006 ZTSSE 30-1200A Electrical Schematic
Minimum Order Quantity
1 piece
Customs Tariff Number
853710
Country of Origin
United States (US)
Package Level 1 Units
crate 1 piece
Controller Type
CG (Level 3)
Neutral Type
No Neutral
Number of Poles
3P
Rated Frequency (f)
Main Circuit 50/60 Hz
Rated Operational Voltage
440 ... 480 V AC
Standards
UL1008
Transition Type
Delayed Transition
Ampere Rating
1000 A
UL Certificate
cULus - CERTIFICATE OF COMPLIANCE - E535104-Vol1-Sec1-20230619
ETIM 8
EC000066 - Power contactor, AC switching
WEEE Category
4. Large Equipment (Any External Dimension More Than 50 cm)
Feature: 3P, 1000 A ampere rating with delayed transition. Business Impact: Reduces arc duration and wear on contacts, increasing reliability and extending service life in heavy motor circuits. Application: Ideal for high-current drives in conveyors, pumps, and fans where robust protection and smooth switching matter. Paragraph 2: Feature: Rated operational voltage 440-480 V AC and rated frequency 50/60 Hz. Business Impact: Ensures compatibility with standard industrial power, reducing misconfiguration and enabling seamless integration with existing switchgear. Application: Three-phase motor control in manufacturing lines and processing equipment. Paragraph 3: Feature: Neutral Type No Neutral. Business Impact: Simplifies wiring, reduces wiring errors, and shortens commissioning. Application: Main circuits for 3P loads where neutral is not required. Paragraph 4: Feature: Controller Type CG (Level 3) and UL 1008 compliance. Business Impact: Provides safe, reliable operation under demanding loads and supports compliance-driven procurement. Application: Heavy-duty control gear in manufacturing and process industries. Paragraph 5: Feature: Documentation such as Operation & Maintenance Manual and Wiring Diagram; WEEE Category 4 Large Equipment. Business Impact: Reduces maintenance time and asset management costs; Application: Streamlined installation and ongoing support. Paragraph 6: Feature: Certifications and classifications: ETIM EC000066; cULus listing. Business Impact: Ensures regulatory compliance and reduces supplier risk; Application: Procurement for regulated industrial environments.
Get a Quick Quote for a ABB 1SCD014312R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SCD014312R1?
Enquire Now
FAQs
Yes. The device is rated for 440–480 V AC main circuits and supports three-phase operation at 50/60 Hz. It uses a 3P configuration and does not require a neutral. When integrating into new or existing lines, verify voltage, current rating, and available space; refer to the wiring diagram and maintenance manuals during installation.
The contactor is rated at 1000 A and is designed for heavy motor protection in manufacturing lines, conveyors, pumps, and large fans. Its delayed-transition feature reduces arcing during switching, improving uptime and lowering maintenance costs in demanding industrial environments.
Delayed transition extends the switch timing to minimize arcing and wear when opening or closing contacts. This enhances contact life, reduces EMI, and supports safer interruption of high-current loads, which is especially beneficial for motors and pumps that switch frequently in production lines.
The product complies with UL 1008 and is listed as cULus, with ETIM EC000066 classification for power contactors. It is designed to meet US-origin requirements and aligns with WEEE categorization for large equipment, supporting compliant procurement and environmental considerations.
Documentation includes the ZTGSE and ZTSSE Operation & Maintenance Manual and the 77A-2006 ZTSSE 30-1200A Electrical Schematic wiring diagram. Access these resources on the product page or through your vendor portal to streamline installation, commissioning, and ongoing maintenance.