ABB 1SCD014357R1 CGSE DT 400A 4P Switch - UL 1008 Certified

Part Number: 1SCD014357R1
Manufacturer
ABB
Part number
1SCD014357R1

Quick Summary

CGSE DT 400A is a high-current protection switch for 3P4W industrial power circuits. In the field, engineers often struggle with finding UL-certified devices that fit 380–415 V AC systems and include clear maintenance documentation. This ABB unit delivers reliability with UL 1008 certification, cULus recognition, and ETIM EC000066 alignment, plus switched neutral for safer energization of downstream loads. Its 4P configuration, 400 A rating, and delayed transition help protect motors and switchgear while minimizing inrush and arc events. Designed for quick installation in ABB panels, it provides standardized wiring diagrams and maintenance manuals to shrink commissioning time. Originating in the United States supports consistent supply, traceability, and compliance reporting for global projects.

Product Information

Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Instructions and Manuals
ZTGSE and ZTSSE Operation & Maintenance Manual
Wiring Diagram
77A-2006 ZTSSE 30-1200A Electrical Schematic
Minimum Order Quantity
1 piece
Customs Tariff Number
853710
Country of Origin
United States (US)
Package Level 1 Units
crate 1 piece
Controller Type
CG (Level 3)
Neutral Type
Switched Neutral
Number of Poles
4P
Rated Frequency (f)
Main Circuit 50/60 Hz
Rated Operational Voltage
380 ... 415 V AC
Standards
UL1008
Transition Type
Delayed Transition
Ampere Rating
400 A
UL Certificate
cULus - CERTIFICATE OF COMPLIANCE - E35022-Vol1-Sec1-20230616
ETIM 8
EC000066 - Power contactor, AC switching
WEEE Category
4. Large Equipment (Any External Dimension More Than 50 cm)
Feature a four-pole design delivering 400 A with a switched neutral and a wide operating voltage range of 380–415 V AC. Business Impact: supports robust protection of high-demand equipment and simplifies integration into standard ABB panel builds, reducing installation time and field rewiring costs. Application: motor control centers and machine panels in manufacturing lines requiring reliable, UL-listed power switching. Feature a delayed transition capability to minimize inrush and arc flash risk. Business Impact: extends contactor life, lowers maintenance cycles, and enhances process reliability. Application: heavy loads such as conveyors, pumps, and HVAC drives where smooth energization matters. Feature UL 1008 compliance and cULus recognition along with ETIM EC000066 alignment. Business Impact: lowers regulatory risk, accelerates procurement, and improves catalog interoperability. Application: critical protection schemes in plant-wide electrical protection and circuit control. Feature 4P configuration with 3P4W compatibility and 50/60 Hz operation. Business Impact: universal applicability across international sites; simplifies spare parts management and cross-border sourcing. Application: multinational facilities needing consistent protection products. Feature Switched Neutral and 380–415 V AC support. Business Impact: enhances sensing accuracy for downstream protection devices and ensures compatibility with modern motor starters. Application: panel feeders and control circuits in automation lines. Feature Comprehensive documentation including wiring diagrams and operation manuals. Business Impact: reduces commissioning time, improves technician onboarding, and supports accurate maintenance planning. Application: field installation and ongoing service for ABB control panels.

Get a Quick Quote for a ABB 1SCD014357R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SCD014357R1? Enquire Now

FAQs

This unit is a 4P, switched-neutral controller rated for 380–415 V AC and 50/60 Hz. It fits standard ABB panel configurations and uses common wiring diagrams (77A-2006) for installation. Ensure enclosure clearance for a 400 A device and verify conductor sizing remains within UL 1008 guidelines to avoid derating and ensure safe operation.
Key specs include four poles (4P), 400 A ampere rating, delayed transition, 380–415 V AC operating voltage, and support for 50/60 Hz mains. The controller type is CG (Level 3) with switched neutral. It complies with UL 1008 and carries cULus recognition, with ETIM EC000066 classification supporting catalog interoperability.
Yes. The 4P, 400 A rating with delayed transition is designed to protect three-phase, four-wire systems and downstream motors, pumps, and drives. Switched neutral aids sensing and protection accuracy, while UL 1008 certification provides the compliance framework needed for motor control centers and automated lines.
The device is UL 1008 certified with cULus recognition, aligned to ETIM EC000066 for power contactor classification. It also falls under WEEE Category 4 for large equipment, and complies with 380–415 V AC, 50/60 Hz operation, supporting safety, environmental, and procurement requirements.
Benefits include reduced downtime due to robust UL-listed protection, minimized inrush with delayed transition, and easier commissioning via standardized wiring diagrams and manuals. The 400 A rating supports scalable protection for growing lines, while readily available documentation and OEM compatibility shorten maintenance cycles and improve overall equipment availability.