ABB 1SCD014406R1 CSSE OT 600A UL 3P 208V 3P3W - UL1008

Part Number: 1SCD014406R1
Manufacturer
ABB
Part number
1SCD014406R1

Quick Summary

ABB 1SCD014406R1 CSSE OT 600A contactor enables reliable 3‑phase control at 208 V in industrial equipment. Manufacturers often struggle with bulky starters and confusing legacy wiring during upgrades. This device is UL 1008 listed, ETIM EC000066 compliant, and falls under WEEE category 4 for large equipment, delivering safety, interoperability, and sustainable disposal. By consolidating motor control into a compact, well-documented unit, you can reduce panel footprint and simplify maintenance. The result is faster commissioning, fewer wiring errors, and improved uptime, while supporting US-origin manufacturing and compatibility with standard control panels. For procurement teams, the combination of 600 A rating and open transition provides tangible ROI in heavy-industry applications like conveyors and presses.

Product Information

Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Instructions and Manuals
ZTGSE and ZTSSE Operation & Maintenance Manual
Wiring Diagram
77A-2007 ZTGDSE 30-1200A Electrical Schematic
Minimum Order Quantity
1 piece
Customs Tariff Number
853710
Country of Origin
United States (US)
Package Level 1 Units
crate 1 piece
Controller Type
CS (Level 4)
Neutral Type
No Neutral
Number of Poles
3P
Rated Frequency (f)
Main Circuit 50/60 Hz
Rated Operational Voltage
208 V AC
Standards
UL1008
Transition Type
Open Transition
Ampere Rating
600 A
UL Certificate
cULus - CERTIFICATE OF COMPLIANCE - E35022-Vol1-Sec1-20230616
ETIM 8
EC000066 - Power contactor, AC switching
WEEE Category
4. Large Equipment (Any External Dimension More Than 50 cm)
Feature: Three-pole, 600 A ampere rating with 208 V AC operation delivers robust control for large motors and heavy loads. Business Impact: Reduces need for parallel contactors and improves protective coordination, lowering installation and maintenance costs. Application: Suitable for conveyors, presses, and machine tools in automotive, packaging, and plastics sectors. Feature: Open transition switching and CS Level 4 controller provide smoother motor start/stop and enhanced protection. Business Impact: Minimizes electrical stress during switching, extending contact life and reducing arc damage. Application: Ideal for process lines requiring clean transfer and reduced downtime. Feature: 50/60 Hz rated frequency and 208 V AC support global networks. Business Impact: Enables reuse across regional power standards, lowering engineering effort. Application: Retrofit and new-build projects in US and international facilities. Feature: UL 1008 certification, cULus documentation, ETIM EC000066 classification, and WEEE category compliance. Business Impact: Simplifies regulatory compliance, safety audits, and sustainable disposal, accelerating supplier qualification. Application: Critical in manufacturing environments with strict compliance requirements. Feature: Wiring diagram availability (77A-2007 ZTGDSE) and CMRT documentation. Business Impact: Accelerates installation and sourcing, reducing panel time and traceability gaps. Application: Useful for retrofits and new builds needing clear, standards-based documentation.

Get a Quick Quote for a ABB 1SCD014406R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SCD014406R1? Enquire Now

FAQs

ABB 1SCD014406R1 uses a standard 3P contactor form factor with three poles and no neutral, rated for 208 V AC at 50/60 Hz. It wires into typical control panels using standard control wiring diagrams such as 77A-2007 ZTGDSE, making retrofit straightforward and reducing panel rework. It remains compatible with common 3-phase buses and protective relays.
The device offers a 600 A ampere rating, three poles (3P), 208 V AC operation, and 50/60 Hz compatibility with open transition switching. UL 1008 compliance and no neutral requirement simplify integration with existing motor control schemes, while ETIM EC000066 classification supports interoperability in cataloging systems.
Yes. The 600 A, 3P configuration is well matched to medium-to-heavy conveyors, presses, and machine tools. Open transition reduces electrical stress during switching, supporting higher uptime in high-cycle environments, while documented wiring diagrams and CMRT data aid fast, compliant deployment.
The product is UL 1008 certified, with cULus documentation and ETIM EC000066 classification. It also falls under WEEE category 4 for large equipment, ensuring regulatory compliance, easier audits, and sustainable end-of-life handling in line with US and international requirements.
Expect reduced maintenance due to robust open-transition switching and a compact form factor that simplifies wiring. The 600 A rating supports longer intervals between replacements, lower panel complexity, and faster commissioning—delivering measurable ROI through improved uptime, lower labor costs, and safer, standardized installation practices.