ABB 1SCD014596R1 CSSE OT 250A UL 4P OLN 480V - UL 1008

Part Number: 1SCD014596R1
Manufacturer
ABB
Part number
1SCD014596R1

Quick Summary

ABB 1SCD014596R1 CSSE OT 250A protects high-current control circuits in industrial switchgear. Engineers often grapple with safe switch-over times and compliance gaps during routine maintenance. This device meets UL 1008, cULus listing, and ETIM EC000066 for reliable classification, with CMRT for responsible sourcing. By pairing a four-pole design with 440–480 V AC operation and a 250 A rating, it delivers precise control and minimizes downtime. The solution also supports streamlined procurement and standardized spares, translating to lower lifecycle costs and faster panel commissioning for industrial automation projects.

Product Information

Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Instructions and Manuals
ZTGSE and ZTSSE Operation & Maintenance Manual
Wiring Diagram
77A-2007 ZTGDSE 30-1200A Electrical Schematic
Minimum Order Quantity
1 piece
Customs Tariff Number
853710
Country of Origin
United States (US)
Package Level 1 Units
crate 1 piece
Controller Type
CS (Level 4)
Neutral Type
Overlapping Neutral
Number of Poles
4P
Rated Frequency (f)
Main Circuit 50/60 Hz
Rated Operational Voltage
440 ... 480 V AC
Standards
UL1008
Transition Type
Open Transition
Ampere Rating
250 A
UL Certificate
cULus - CERTIFICATE OF COMPLIANCE - E35022-Vol1-Sec1-20230616
ETIM 8
EC000066 - Power contactor, AC switching
WEEE Category
4. Large Equipment (Any External Dimension More Than 50 cm)
Feature: Four-pole, 4P design with 250 A ampere rating and 440–480 V AC operation. Business Impact: Enables robust power switching for motors and heavy loads with predictable performance, improving uptime and safety in industrial switchgear. Application: Suitable for motor control centers and distribution panels in manufacturing environments. Feature: CS (Level 4) controller type. Business Impact: Delivers precise sequencing and reliable open-transition control, reducing surprise outages and improving commissioning speed. Application: Used in automation panels requiring deterministic control. Feature: Overlapping Neutral neutral configuration. Business Impact: Balances multi-phase loads, minimizes neutral overcurrent, and simplifies wire management. Application: Multi-mop drives and mixed-load panels. Feature: CMRT and ETIM EC000066 classification. Business Impact: Supports responsible sourcing and easy cataloging, aiding procurement and compliance reporting. Application: Enterprise supply chains with ethics and ESG considerations. Feature: UL1008 certification and cULus listing. Business Impact: Enables code-compliant installations and safer risk management for critical infrastructure. Application: U.S. and global safety-compliant switchgear deployments. Feature: Wiring diagrams and manuals availability. Business Impact: Reduces installation time and field errors, accelerating project timelines. Application: Field deployment and service teams needing quick reference.

Get a Quick Quote for a ABB 1SCD014596R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SCD014596R1? Enquire Now

FAQs

This model leverages standard 4P open-transition wiring schemes and is compatible with ABB ZTGSE 30-1200A electrical schematics. When wiring to 440–480 V AC supplies, follow the ZTGDSE documentation for exact terminal mapping, sequence timing, and neutral integration. Proper phasing and torque specs reduce contact wear and ensure safe, predictable operation in panel assemblies.
Open-transition switching avoids arcing during pole-to-pole transitions, reducing transient current spikes and electrical noise. The 250 A rating provides a margin for startup loads, while the 50/60 Hz rated circuit ensures consistent switching at typical industrial frequencies. This results in longer contact life, lower EMI, and improved overall reliability in motor control and distribution panels.
Yes. The device is designed for 440–480 V AC operation with UL 1008 certification and cULus listing, aligning with common US and international industrial practices. The 4P configuration and 250 A rating support heavy-duty motor control and power distribution needs, making it a practical choice for US manufacturing environments seeking compliant, robust protection.
The product carries UL 1008 certification, cULus listing, and ETIM EC000066 classification for power contactors in AC switching. CMRT confirms conflict minerals reporting, and WEEE categorization supports end-of-life compliance. These credentials simplify regulatory alignment, supplier audits, and ESG reporting for procurement and engineering teams.
The four-pole, open-transition design reduces commissioning time and minimizes field-erected wiring errors, delivering faster panel startup. The reliable 250 A rating and 440–480 V compatibility cut spare parts and maintenance costs while improving uptime. Coupled with documented wiring diagrams and manuals, customers experience lower lifecycle risk and higher project predictability.