ABB 1SCD014724R1 CSSE DT Contactor - UL1008, 3P, 480V

Part Number: 1SCD014724R1
Manufacturer
ABB
Part number
1SCD014724R1

Quick Summary

The ABB 1SCD014724R1 CSSE DT contactor provides robust three‑pole motor control for 480V systems. Engineers often struggle with arc suppression, inrush management, and maintaining consistent UL/cUL compliance across multiple sites. This unit carries UL1008 listing, cULus certification, and ETIM 8 EC000066 compatibility to streamline procurement and installation. With CS Level 4 control integration, it supports reliable remote operation while delivering safe, maintainable protection for industrial equipment. Designed for electrical protection and circuit control workflows, it also aligns with global standards, helping you reduce risk and accelerate project timelines without compromising on performance.

Product Information

Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Instructions and Manuals
ZTGSE and ZTSSE Operation & Maintenance Manual
Wiring Diagram
77A-2008 ZTSDSE 30-1200A Electrical Schematic
Minimum Order Quantity
1 piece
Customs Tariff Number
853710
Country of Origin
United States (US)
Package Level 1 Units
crate 1 piece
Controller Type
CS (Level 4)
Neutral Type
Solid Neutral Bar
Number of Poles
3P
Rated Frequency (f)
Main Circuit 50/60 Hz
Rated Operational Voltage
440 ... 480 V AC
Standards
UL1008
Transition Type
Delayed Transition
Ampere Rating
100 A
UL Certificate
cULus - CERTIFICATE OF COMPLIANCE - E35022-Vol1-Sec1-20230616
ETIM 8
EC000066 - Power contactor, AC switching
WEEE Category
4. Large Equipment (Any External Dimension More Than 50 cm)
Feature → Business Impact → Application: The 3P 100 A rating aligns with demanding motor control tasks, delivering reliable switching for conveyors, pumps, and machines with minimal voltage drop and reduced wear on contacts. This supports improved energy efficiency and longer service life, reducing maintenance costs in continuous‑run environments. Application: three‑phase motor control in packaging lines or material handling systems. Feature → Business Impact → Application: Delayed transition switching reduces inrush currents and electrical arcing, extending contact life and protecting upstream drives. This improves startup reliability for fan drives, compressors, and lift stations, particularly in systems with frequent startup cycles. Application: heavy machinery start/stop cycles in manufacturing floors. Feature → Business Impact → Application: Rated 440 … 480 V AC main circuit compatibility ensures seamless integration with typical North American and international power distribution. This simplifies panel design, lowers wiring errors, and accelerates installation across multiple sites. Application: new installations and retrofit projects in industrial plants. Feature → Business Impact → Application: Solid neutral bar simplifies neutral connections and reduces terminal clutter, improving wiring integrity and fault tracing during maintenance. Application: control panels and power distribution hubs in warehouses. Feature → Business Impact → Application: CS (Level 4) controller type provides structured control logic compatible with existing automation platforms, facilitating easier programming, diagnostics, and integration with HMI/PLC systems. Application: automation suites and line control in food and beverage, automotive, and processing industries. Feature → Business Impact → Application: UL 1008 and cULus certifications, plus ETIM 8 EC000066 alignment, mitigate compliance risk and streamline supplier qualification. Application: regulated industries and global deployments seeking certified components. Feature → Business Impact → Application: Access to wiring diagrams (77A‑2008 ZTSDSE 30‑1200A) and operation manuals supports fast commissioning and reduced downtime. Application: field service and retrofits with minimal guesswork.

Get a Quick Quote for a ABB 1SCD014724R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SCD014724R1? Enquire Now

FAQs

This 3P 100 A contactor is rated for 440–480 V AC mains and 50/60 Hz, with a solid neutral bar and CS Level 4 control. For fastest commissioning, refer to the 77A-2008 ZTSDSE wiring schematic and the ZTSE operation manuals to ensure correct coil wiring, coil voltage, and control circuit compatibility.
Key specs include three poles (3P), 100 A ampere rating, delayed transition type, 440–480 V AC operation, and 50/60 Hz compatibility. It is UL1008 listed and under cULus certification, with a solid neutral bar to simplify neutral wiring and improve circuit reliability.
Yes. Its 3P configuration and 100 A rating suit medium‑duty motor control in conveyors, pumps, and processing lines. The delayed transition feature reduces inrush and arc wear, enhancing motor life and reducing maintenance intervals in continuous operation environments.
It carries UL1008 listing, a cULus certificate of compliance, and ETIM 8 EC000066 classification for power contactors, AC switching. These certifications simplify procurement, compliance audits, and cross‑border deployment in regulated industries.
Utilize the wiring diagram 77A-2008 ZTSDSE for precise wiring, verify CS Level 4 compatibility with your PLC/HMI, and perform periodic arc‑contact inspections. The robust 3P 100 A rating and UL/cUL compliance reduce downtime, extend service life, and lower replacement costs in high‑cycle applications.