ABB 1SCD014758R1 CSSE DT 30A - UL 1008 Certified

Part Number: 1SCD014758R1
Manufacturer
ABB
Part number
1SCD014758R1

Quick Summary

ABB CSSE DT 30A is a 4P circuit protector designed for industrial power control in distribution panels. Operators often contend with arcing and contact wear when switching large loads, especially in environments with mixed 50/60 Hz power. UL 1008 certification and a cULus listing, plus ETIM EC000066 classification and WEEE compliance, back up reliable procurement and global compatibility. For panel builders and OEMs, the combination of a 3P4W configuration and switched neutral simplifies wiring and accelerates installation, while the 380–415 V rating ensures broad field applicability.

Product Information

Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Instructions and Manuals
ZTGSE and ZTSSE Operation & Maintenance Manual
Wiring Diagram
77A-2008 ZTSDSE 30-1200A Electrical Schematic
Minimum Order Quantity
1 piece
Customs Tariff Number
853710
Country of Origin
United States (US)
Package Level 1 Units
crate 1 piece
Controller Type
CS (Level 4)
Neutral Type
Switched Neutral
Number of Poles
4P
Rated Frequency (f)
Main Circuit 50/60 Hz
Rated Operational Voltage
380 ... 415 V AC
Standards
UL1008
Transition Type
Delayed Transition
Ampere Rating
30 A
UL Certificate
cULus - CERTIFICATE OF COMPLIANCE - E35022-Vol1-Sec1-20230616
ETIM 8
EC000066 - Power contactor, AC switching
WEEE Category
4. Large Equipment (Any External Dimension More Than 50 cm)
Feature: Four-pole design with a 30 A rating for 380-415 V AC mains. Business Impact: Delivers robust overload protection across three-phase four-wire networks, reducing nuisance trips and unplanned downtime. Application: Ideal for distribution panels, machine control enclosures, and motor control centers in manufacturing environments. Feature: CS (Level 4) controller type provides advanced control logic. Business Impact: Improves sequencing accuracy and safety in high-energy circuits, reducing operator exposure to surges. Application: Suitable for OEM equipment and panel builders needing reliable switchgear control in automated lines. Feature: Delayed Transition minimizes arcing and wear. Business Impact: Extends contact life and lowers maintenance costs over the device lifecycle. Application: Works well in heavy-duty conveyors, presses, and injection-molding machines. Feature: Switched Neutral configuration supports safer fault isolation. Business Impact: Simplifies wiring schemes and reduces risk of neutral-related faults. Application: 3P4W networks in control panels and machine starters across industrial settings. Feature: Documentation and sourcing options including minimum order quantity of 1 piece and crate packaging. Business Impact: Facilitates rapid prototyping and scalable procurement for growing projects. Application: Panel shops, contract manufacturers, and OEMs integrating modular protection in build-outs. Feature: Compliance coverage with UL 1008, cULus, ETIM EC000066, and WEEE alignment. Business Impact: Supports regulatory compliance, sustainability goals, and supplier risk reduction. Application: Global deployments in automotive, packaging, or process industries requiring proven protection.

Get a Quick Quote for a ABB 1SCD014758R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SCD014758R1? Enquire Now

FAQs

Plan for a four-pole, switched-neutral integration in a 380–415 V AC system and reference the 77A-2008 ZTSDSE electrical schematic for wiring guidance. Use appropriate enclosures, secure mounting, and verify compatible 50/60 Hz mains. Ensure UL 1008 compliance and observe safe wiring practices to minimize arc risks during startup and cycling.
Key specs include a 30 A ampere rating, 4P configuration, 380–415 V AC operating range, and 50/60 Hz compatibility. The controller is CS Level 4, with delayed transition to reduce arcing. It carries UL 1008 certification and a cULus listing, ensuring robust protection and regulatory alignment for industrial panels.
Yes, it is suitable for 3P4W networks in control panels and machine starters, offering switched neutral for safer fault isolation and simplified wiring. The device’s UL/cULus certification and ETIM classification support cross-industry deployment, while the 380–415 V range covers many regional power architectures common in process and automation environments.
Expect UL 1008 certification, a cULus listing, and WEEE compliance. ETIM EC000066 classification (Power contactor, AC switching) supports interoperability with other equipment, and the product aligns with global procurement standards for industrial protection and circuit control components.
The delayed transition feature reduces electrical arcing, extending contact life and lowering maintenance costs. Its 4P 30 A protection suits high-energy loads, while the switched neutral simplifies wiring, enabling faster installations and fewer commissioning issues—delivering tangible uptime gains and shorter project timelines for OEMs and panel shops.