ABB 1SCD014762R1 CSSE DT 200A UL 4P 415V 3P4W - UL1008

Part Number: 1SCD014762R1
Manufacturer
ABB
Part number
1SCD014762R1

Quick Summary

ABB 1SCD014762R1 CSSE DT 200A is a four-pole contact solution for 380–415 V industrial panels. Engineers struggle with high-current switching reliability, safe neutral handling, and regulatory compliance in compact panels. This device meets UL 1008 standards, uses switched neutral, and supports 50/60 Hz operation, with USA origin. In addition to high-current performance, it aligns with industry standards and simplifies panel integration for OEMs and service teams. Manufacturers benefit from predictable lifecycle costs, reduced maintenance intervals, and faster panel commissioning. And the compact form supports space-constrained enclosures without compromising safety. Combined with ABB's engineering support, projects stay on schedule and meet strict uptime targets.

Product Information

Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Instructions and Manuals
ZTGSE and ZTSSE Operation & Maintenance Manual
Wiring Diagram
77A-2008 ZTSDSE 30-1200A Electrical Schematic
Minimum Order Quantity
1 piece
Customs Tariff Number
853710
Country of Origin
United States (US)
Package Level 1 Units
crate 1 piece
Controller Type
CS (Level 4)
Neutral Type
Switched Neutral
Number of Poles
4P
Rated Frequency (f)
Main Circuit 50/60 Hz
Rated Operational Voltage
380 ... 415 V AC
Standards
UL1008
Transition Type
Delayed Transition
Ampere Rating
200 A
UL Certificate
cULus - CERTIFICATE OF COMPLIANCE - E35022-Vol1-Sec1-20230616
ETIM 8
EC000066 - Power contactor, AC switching
WEEE Category
4. Large Equipment (Any External Dimension More Than 50 cm)
Feature: High current capability of 200 A and 4P configuration. Business Impact: Enables reliable switching of large loads in motor control and power distribution, reducing contact wear and downtime. Application: Suitable for mains and feeders in industrial equipment where space and reliability matter. Feature: Switched Neutral construction. Business Impact: Improves control-circuit safety and simplifies PLC/wiring schemes, lowering wiring errors in control panels. Application: Ideal for centralized control in automation cabinets. Feature: Rated for 380–415 V AC and 50/60 Hz. Business Impact: Provides regional versatility and compatibility with global installations, reducing part variety. Application: Global OEMs can standardize panels across regions. Feature: Delayed Transition (soft-start) capability. Business Impact: Minimizes inrush, lowers mechanical stress on contacts, and extends equipment life. Application: Heavy machinery and conveyors during start-up. Feature: CS (Level 4) controller type. Business Impact: Delivers robust control logic for sequencing and safety interlocks, improving uptime. Application: Integrated into CS-series control schemes in industrial plants. Feature: UL 1008 certification and cULus listing. Business Impact: Enables regulatory compliance, faster audits, and safer procurement. Application: Required in critical safety and energy-management enclosures. Feature: 4P configuration with Switched Neutral for 200 A operations. Business Impact: Simplifies wiring topology while delivering dependable power switching. Application: Control panels and motor-control centers in manufacturing settings. Feature: US origin and standard wiring diagrams availability. Business Impact: Reduces supply chain risk and accelerates commissioning with available schematics. Application: OEMs planning regional builds and service teams performing maintenance.

Get a Quick Quote for a ABB 1SCD014762R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SCD014762R1? Enquire Now

FAQs

The 1SCD014762R1 is rated for 380-415 V AC, 50/60 Hz, with a 4-pole configuration and switched neutral. It fits standard industrial panels and motor-control centers, offering reliable high-current switching up to 200 A. This makes it well-suited for mainstream automation and power distribution applications in manufacturing environments.
Install with four-pole wiring for the main circuit and ensure the switched-neutral control circuit is correctly wired to the CS Level 4 control input. Refer to the 77A-2008 wiring diagram for guidance, and verify packaging is crate-based (1 piece per crate) to match your panel layout and logistics.
Yes. The device conforms to UL1008 standards and carries a cULus certification. This certification supports compliance for industrial control equipment in North America, helping with regulatory audits, safety reviews, and customer qualification processes.
Common applications include motor control centers, automated conveyors, and power distribution panels in manufacturing plants. The 200 A, 4P configuration with delayed transition suits equipment requiring reliable, controlled start-up and safe neutral handling within 380–415 V systems.
Switched neutral enables safer control circuits and reduces voltage stress on PLCs and control devices. It simplifies wiring schemes in control panels and improves protection against unintended neutral energization, contributing to longer control-system life and easier maintenance.