ABB 1SDA037394R1 Accessory - TOROIDAL CT ON D.60MM RCQ
Part Number: 1SDA037394R1
Quick Summary
ABB 1SDA037394R1 is a toroidal current transformer accessory for monitoring loads in SACE Tmax XT and Emax switchgear. In dense electrical cabinets, accurate sensing and quick installation can be a costly bottleneck. This ABB accessory ships with RoHS and REACH declarations and a CE-conformity context, supporting compliant integration. Designed for SACE Tmax XT, Tmax T, and Emax families, it reduces wiring, speeds commissioning, and improves protection accuracy. The device is compatible with standard ABB installations and supports IEC-based configurations, ensuring consistent performance across maintenance cycles. By enabling precise current measurement where space and accessibility are limited, it helps lower downtime and service costs.
Product Information
Extended Description
1SDA037394R1 ABB: TOROIDAL CT ON D.60MM RCQ
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
Document availability on demand
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
1SDC210015D0201
Order Code US and Canada
KXTTETOR60
EAN
8015644373948
Minimum Order Quantity
1 piece
Customs Tariff Number
85389099
Product Net Width
110 mm
Product Net Height
30 mm
Product Net Depth / Length
160 mm
Product Net Weight
0.492 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
110 mm
Package Level 1 Height
30 mm
Package Level 1 Depth / Length
160 mm
Package Level 1 Gross Weight
0.518 kg
Package Level 1 EAN
8015644373948
Product Main Type
Accessories for Emax 2, Accessories for Tmax XT
Product Name
Accessory
Product Type
ACC
Suitable For
XT1 | XT2 | XT3 | XT4 | XT5 | XT6 | XT7-XT7M | T1 | T2 | T3 | T4 | T5 | T6 | T7 | S4 | S5 | S6 | S7 | E1 | E2 | E3 | E4 | E6
Suitable for Product Class
SACE Emax, SACE Tmax XT, SACE Tmax T, SACE Isomax
Configuration Type
Loose or configurable
Order Multiple
1 piece
Standards
IEC
Data Sheet, Technical Information
SACE Tmax XT
Declaration of Conformity - CE
EC Declaration of Conformity Tmax T8
ETIM 8
EC002498 - Accessories/spare parts for low-voltage switch technology
ETIM 9
EC002498 - Accessories/spare parts for low-voltage switch technology
IDEA Granular Category Code (IGCC)
4189 >> Torroidal Current Transformers
Object Classification Code
Q
UNSPSC
39121032
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27371392
Feature: Toroidal current transformer design with a 60 mm opening (D.60MM) enables compact panel integration and straightforward mounting. Business Impact: Reduces installation time and wiring complexity, cutting field labor costs. Application: Ideal for ABB SACE Tmax XT and Emax installations where space is constrained and accurate current sensing is essential. Feature: RoHS and REACH declarations plus TSCA and environmental data provide regulatory assurance. Business Impact: Facilitates global compliance and smoother audits, enabling faster market access. Application: Suitable for multi-region deployments in EU, US, and other regions with strict material controls. Feature: CE conformity and DoC references streamline certification workflows. Business Impact: Shortens commissioning cycles and preserves project timelines. Application: Fits tightly regulated projects needing formal declarations and reliable performance data. Feature: Minimum order quantity of 1 piece and box packaging offer predictable procurement. Business Impact: Reduces inventory risk and simplifies stocking for maintenance contracts. Application: Supports single-unit replacements and kitting for service teams. Feature: Broad compatibility with SACE Emax, Tmax XT, and Tmax T families. Business Impact: Lowers SKU proliferation and simplifies spare-part strategy. Application: Enables a unified spare-part approach across multiple product generations. Feature: Includes essential product data such as EAN, tariff code, and standards references. Business Impact: Improves data accuracy for ERP and procurement workflows. Application: Enhances traceability and compliance in asset registers and BOMs.
Get a Quick Quote for a ABB 1SDA037394R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA037394R1?
Enquire Now
FAQs
Begin by confirming panel clearances for a D.60mm toroidal CT opening. Mount the accessory in the designated current-sensing path, ensuring the conductors pass cleanly through the toroid. Connect any required cable harnesses per the SACE Tmax XT installation guide, then validate alignment with the system software and perform a commissioning check to verify accurate current readings.
The device is a toroidal current transformer with a 60 mm opening (D.60MM RCQ) designed for current sensing in low-voltage switchgear. It is intended for use with ABB SACE Tmax XT, Tmax T, and Emax families, providing precise monitoring in restricted or compact panel spaces. Specific current ratios and accuracy data are provided in the SACE Tmax XT data sheet.
Yes. The product carries RoHS information and adheres to EU Directive 2011/65/EU with the 2015/863 amendment. REACH declarations are available for ABB Sace circuit breakers, and a CE conformity declaration is included for Tmax T8. TSCA declarations are also available, supporting multi-region compliance.
The minimum order quantity is 1 piece, with packaging described as package level 1 units in a box containing 1 piece. The EAN for ordering is 8015644373948, and the US/Canada order code is KXTTETOR60, which simplifies reordering and stock management.
Toroidal CTs offer non-contact current sensing with minimal wiring complexity, reducing assembly time and potential installation errors. The 1SDA037394R1 variant supports multiple product families (XT, T, Emax), enabling a single spare-part strategy across platforms, lowering stocking costs, improving uptime, and delivering predictable maintenance budgets.