ABB 1SDA050467R1 Moulded Case Circuit Breaker - IEC 947-2

Part Number: 1SDA050467R1
Manufacturer
ABB
Part number
1SDA050467R1

Quick Summary

ABB 1SDA050467R1 moulded case circuit breaker protects electrical distribution panels from overloads in industrial automation environments. This device delivers reliable fault protection while simplifying wiring in compact switchgear. Engineers often face panel-space constraints and the need for rapid, safe maintenance without compromising protection performance. The Isomax S6 family is CE marked, RoHS compliant, and specified to IEC 947-2, supporting regulatory alignment in many facilities. With front-terminal connections, fixed release, and a 630 A rating, it provides dependable protection for high-demand circuits. Choosing Isomax S6 helps reduce downtime, streamline installation, and improve lifecycle costs, while supporting compatibility with Isomax and Isomax S5 systems. It’s a solid choice for manufacturing, process control, and distribution applications.

Product Information

Extended Description

1SDA050467R1 ABB: CIRCUIT-BREAKER ISOMAX S6L 630 1000V FOUR-POLE FIXED WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE AC R 630-6300 A FULLY RATED
RoHS Information
1SDL000194R0001
Environmental Information
1SDL000141R0
EAN
8015644506247
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
305 mm
Product Net Height
285 mm
Product Net Depth / Length
0.1035 m
Product Net Weight
12 kg
Package Level 1 Units
1 piece
Package Level 1 Height
285 mm
Package Level 1 Depth / Length
305 mm
Package Level 1 Gross Weight
24.2 kg
Package Level 1 EAN
8015644506247
Product Main Type
SACE Isomax
Product Name
Moulded Case Circuit Breaker
Suitable For
Isomax S5
Suitable for Product Class
Isomax
Version
Fixed
Electrical Durability
7000
Number of Poles
4P
Power Loss
100 W
Rated Current (In)
630 A
Rated Operational Voltage
690 V AC
Release Type
TadjMadj
Short-Circuit Performance Level
L
Standards
IEC947-2
Sub-type
S6
Terminal Connection Type
Front
Test Voltage at Industrial Frequency for 1 Minute
3000 V
Data Sheet, Technical Information
ITSCE-604050012
Declaration of Conformity - CE
1SDL000160R0041
Instructions and Manuals
Instructions for installation S6
Object Classification Code
Q
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Front-terminal, four-pole fixed construction simplifies wiring and panel assembly. That design minimizes wiring errors, speeds commissioning, and improves overall enclosure reliability in busy production lines. Isomax S6 with front terminals is well-suited for new builds and retrofit projects in factory floors. 630 A rated current handles large feeders and motor circuits without frequent protection trips. This enables closer load sharing and reduces nuisance trips during peak startup currents. Ideal for distribution panels in packaging, metals, and process industries. 690 V AC rating supports widespread industrial networks and safer operation across multi-phase installations. The four-pole configuration ensures consistent protection across all phases, including neutral where present. Applications include motor control centers and feeder panels in factories and water treatment facilities. Thermomagnetic release (TadjMadj) provides fast, reliable tripping under overloads and short circuits. This improves safety, reduces arc energy, and minimizes equipment damage in critical lines. It also simplifies coordination with upstream protective devices and downstream fuses. Power loss of 100 W reflects efficient internal protection while contributing to manageable enclosure temperatures. Net weight 12 kg and compact footprint support easier handling, removal, and retrofit work. The 305 mm width and 285 mm height fit standard switchgear racks and easily integrate with Isomax panels. RoHS compliance and CE declaration ensure regulatory alignment across global supply chains. EAN 8015644506247 supports precise procurement and inventory control. These certifications reassure spec-conscious engineers during design reviews and audits.

Get a Quick Quote for a ABB 1SDA050467R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA050467R1? Enquire Now

FAQs

The ABB 1SDA050467R1 is designed as a fixed, four-pole MCCB with front-terminal connections, making it highly compatible with Isomax S6 panel assemblies. Its 630 A rating and 690 V AC capability align with common Isomax S6 configurations, simplifying retrofits and new builds. When wiring, ensure the front-access terminals are fully tightened and that the release mechanism is correctly oriented for TadjMadj protection.
Key specs include four poles (4P), 630 A rated current, 690 V AC rated operational voltage, front-terminal connections, and a thermomagnetic release (TadjMadj). The short-circuit protection level is rated as L. It supports a test voltage of 3000 V and a power loss of about 100 W, with RoHS and IEC 947-2 standard considerations for compliance.
Yes. The device is CE declared and RoHS compliant, as indicated by the CE declaration and RoHS information in the product data. These certifications support regulatory compliance across many regions and facilitate acceptance in engineering reviews, audits, and supplier qualification processes for panel builders and OEMs.
Yes. The unit is rated for 690 V AC operation, making it suitable for industrial distribution panels and motor control centers that require high-voltage protection. The four-pole design ensures proper phase coordination, which is essential for safe operation in multi-phase networks typical of factories and process facilities.
Installation with front-terminal access reduces wiring errors and speeds commissioning, lowering labor costs during setup. The robust Isomax S6 protection provides reliable trip performance (L-level short-circuit) and durable operation, which can lower downtime and maintenance frequency. Over time, these factors contribute to a favorable total cost of ownership in manufacturing and distribution environments.