ABB 1SDA054383R1 Moulded Case Circuit Breaker - IEC
Part Number: 1SDA054383R1
Quick Summary
ABB 1SDA054383R1 Moulded Case Circuit Breaker provides reliable overcurrent protection for three-phase drives and feeders in industrial panels. Engineers often struggle with space constraints and the need for front-access releases when upgrading legacy gear. This device aligns with IEC standards and CE declarations, and is supported by RoHS, REACH, and a GL certificate, helping you meet regulatory demands with minimal effort. With a 400 A rating, 690 V AC operation, and a 200 kA short-circuit capacity, it delivers strong fault protection while keeping energy losses manageable (approximately 16.5 W per pole). Front terminals simplify wiring and servicing, and the Tmax T5 family compatibility ensures straightforward panel integration, reducing commissioning time and easing spare-part management for mid-to-large electrical rooms.
Product Information
Extended Description
1SDA054383R1 ABB: C.BREAKER TMAX T5V 400 FIXED THREE-POLE WITH FRONT TERMINALS AND SOLID-STATE RELEASE IN AC PR221DS-I R 400
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
SCIP
7b403046-2354-44c8-8f1a-ce99f6d5a5e4 China (CN)
Simplified SCIP
0febfe4d-6224-45c2-add1-c6441d86c250 Greece (GR) | 675d8c65-27f4-48ef-93fc-aa8514d9ef89 Netherlands (NL) | e0892783-f6cd-4832-8b11-f962dfd461b9 Belgium (BE) | 992b76dc-52ee-4453-b30b-3b0992829f30 Sweden (SE) | 7e727722-3aa7-41d4-ba26-4d262e0e89bd Poland (PL) | e0cd5a7f-9614-4709-b3b6-586b9376e4f4 Bulgaria (BG) | 21b763eb-9e81-4a8d-9ce8-f127540c6ce8 Poland (PL) | 4997ef52-a60f-4f3e-bb54-8927a48b5b9d Sweden (SE) | fe707bc8-c751-497f-9edb-f68189bc32fd France (FR) | aa4b118e-62ee-4b87-821e-45f50d19167a Germany (DE) | 87602f8a-b33b-4c5d-914a-f6147ae44da4 Germany (DE) | bdcc2186-5c0f-4e56-9d81-a884936da2b5 France (FR) | 1174671c-ec16-4547-945e-e332322364f5 Germany (DE) | 7968d3d0-4e5b-445c-bc9c-0c405a468362 Hungary (HU) | 4b2883e2-2339-48dd-8b34-bb69c00611ff Czech Republic (CZ) | f2711ba3-4383-445c-9958-ddc5e0b0a494 Poland (PL) | db61c71b-6b94-42b8-b525-e84ea2957c89 Spain (ES) | 80051a58-7ad9-467a-8440-7242f32f3ed1 Portugal (PT) | 03ebf849-af88-4bd7-aec5-5b5d32826888 Denmark (DK) | 9ca7139d-3f13-49cc-9fe6-5b7f05b77f20 Germany (DE) | 03b8f0ff-62c1-4c3f-a56b-cce8c8286115 Finland (FI) | 2d70d472-7550-4ac8-9cc1-b5c219ceea54 Norway (NO) | 93490da2-4aee-4ae4-aaa0-738e49e55156 Germany (DE)
Environmental Information
Product Environmental Information Tmax T5 | Breakers - Packaging disposal information
E-Number (Finland)
3655540
EAN
8015644554811
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
140 mm
Product Net Height
205 mm
Product Net Depth / Length
103.5 mm
Product Net Weight
5.1 kg
Package Level 1 Units
1 piece
Package Level 1 Width
248 mm
Package Level 1 Height
240 mm
Package Level 1 Depth / Length
285 mm
Package Level 1 Gross Weight
5.1 kg
Package Level 1 EAN
8015644554811
Product Main Type
SACE Tmax T
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable For
T5
Suitable for Product Class
Moulded Case Circuit Breakers
Version
F
Electrical Durability
7000 cycle | 60 cycles per hour
Mechanical Durability
20000 cycle | 120 cycles per hour
Number of Poles
3P
Power Loss
at Rated Operating Conditions per Pole 16.5 W
Rated Current (In)
400 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 200 kA | (230 V AC) 200 kA | (380 V AC) 200 kA | (400 V AC) 200 kA | (415 V AC) 200 kA | (440 V AC) 180 kA | (500 V AC) 150 kA | (690 V AC) 80 kA
Rated Short-time Withstand Current Low Voltage (Icw)
for 1 s 5 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 200 kA | (230 V AC) 200 kA | (380 V AC) 200 kA | (400 V AC) 200 kA | (415 V AC) 200 kA | (440 V AC) 180 kA | (500 V AC) 150 kA | (690 V AC) 80 kA
Rated Uninterrupted Current (Iu)
400 A
Release
PR221DS-I
Release Type
EL
Short-Circuit Performance Level
V
Standards
IEC
Sub-type
T5
Terminal Connection Type
Fixed Circuit-Breakers | Front
Test Voltage Max (Utest)
3500 V
Test Voltage at Industrial Frequency for 1 Minute
3500 V
Data Sheet, Technical Information
1SDC210004D0203
Declaration of Conformity - CE
EC Declaration of Conformity Tmax T5
GL Certificate
1SDL000163R0062
Instructions and Manuals
Installation instructions Tmax T5
Instructions and Manuals (Part 2)
ITSCE-RH0100001
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39121100
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature → 3P fixed front-terminal design with PR221DS-I solid-state release enhances dependable tripping and visible status indication, reducing mean time to repair and accelerating fault isolation in demanding environments. Benefit → Faster, safer maintenance and minimized downtime in critical MCCs and feeders. Application → Suitable for industrial control panels where front-access wiring is required and rapid response matters. Feature → 400 A rated current and 690 V AC operating voltage provide robust protection for large motors and transformers without excessive panel footprint. Benefit → More capable protection in a compact footprint, lowering space costs and enabling simpler cabinet design. Application → Motor control centers and incoming feeders in manufacturing facilities. Feature → High fault-stability metrics Ics 200 kA, Icu 200 kA and 5 kA for 1 s Icw plus 8 kV test voltage ensure resilience against severe faults. Benefit → Regulatory and utility approval confidence, reduced risk of cascading outages. Application → Critical power distribution and transformer protection in power-heavy plants. Feature → Comprehensive compliance and sustainability declarations RoHS, REACH, CMRT, TSCA, CE with clear documentation. Benefit → Simplified procurement, risk management, and lifecycle planning. Application → Industries with strict supply-chain and environmental requirements. Feature → Physical and installation advantages 140 mm width, 205 mm height, 103.5 mm depth, 5.1 kg weight with front-terminal access. Benefit → Easier retrofits and faster installation in dense panels. Application → Panel upgrades in space-constrained electrical rooms.
Get a Quick Quote for a ABB 1SDA054383R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA054383R1?
Enquire Now
FAQs
The 3P fixed front-terminal configuration simplifies wiring by bringing connections to the front of the device, enabling quicker wiring access and easier maintenance in compact panel layouts. Ensure adequate clearance for front-access installation and follow the included installation instructions to maintain reliable tripping performance and safe operation during servicing.
It features a 200 kA short-circuit current rating (Ics) and a 200 kA ultimate breaking capacity (Icu) across standard voltages, with 5 kA short-time withstand (Icw) for 1 s. An 8 kV test voltage rating confirms robust insulation, providing strong protection against severe faults in medium-to-large industrial systems.
Yes. Its 400 A rating, 690 V AC operating voltage, fixed front terminals, and high Ics/Icu values make it ideal for motor control centers and feed-distribution panels in demanding environments. The device’s mechanical and electrical durability support long service life, reducing replacement frequency and downtime in heavy industry applications.
This breaker ships with CE Declaration of Conformity, IEC compliance, RoHS and REACH declarations, CMRT for conflict minerals, and TSCA declarations. A GL certificate is also available, along with standard documentation such as instructions and data sheets to support regulatory and quality audits.
The unit’s high durability—up to 7000 electrical cycles and 20,000 mechanical cycles—minimizes maintenance downtime. Low energy losses (16.5 W per pole) reduce energy consumption over time, while front-terminal design speeds servicing. Together with robust fault protection and easy acquisition of spare parts, this translates to lower life-cycle cost and improved uptime.