ABB 1SDA054411R1 Tmax T5S 630 - PR222DS/P-LSIG

Part Number: 1SDA054411R1
Manufacturer
ABB
Part number
1SDA054411R1

Quick Summary

ABB 1SDA054411R1 Moulded Case Circuit Breaker protects industrial power networks in panel installations. It delivers reliable fault protection with front-terminal access, reducing wiring errors and maintenance downtime. This Tmax T5S device complies with IEC standards, carries a CE Declaration of Conformity, and supports RoHS requirements for safer, regulation-ready operation across global sites. Designed for high-current distribution, it supports 630 A ratings with robust short-circuit capability up to 85 kA at various voltages and a rated operational voltage of 690 V AC. With a 4P fixed frame and PR222DS/P-LSIG release, installation and service are streamlined, delivering safer, more efficient electrical protection in industrial automation and power distribution environments.

Product Information

Extended Description

1SDA054411R1 ABB: C.BREAKER TMAX T5S 630 FIXED FOUR-POLE WITH FRONT TERMINALS AND SOLID-STATE RELEASE IN AC PR222DS/P-LSIG R 630
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
SCIP
a92953ab-29b9-4d88-97ef-ada729985e69 China (CN)
Simplified SCIP
0c4dbb69-ce67-4a06-9aae-86aca2f5f608 Poland (PL) | c3a00d03-6e82-4cd6-8630-f2f0e96a4bea Czech Republic (CZ) | 59f4203f-08ba-4b42-9d10-1c3c7b2a08d2 Germany (DE) | 5d80903c-fed1-479d-980f-dd82da878b17 Croatia (HR) | c61dfbdd-ebe8-43a2-a06a-5a42d270d1c9 Norway (NO) | 84ba9847-90e7-430b-81fe-607f28157f2a Belgium (BE) | 0ed5c5e6-ad46-4865-8baf-862e567d7a5f Finland (FI) | 34fd3728-f3db-44da-be96-b69f147974ee Germany (DE) | 273e633f-629e-4534-9392-d7769f686da8 Denmark (DK) | 05144bed-1350-4ad2-8b2f-5777a873b613 Germany (DE) | d488b087-8e44-4146-ac70-1690f2f380b1 Greece (GR) | 944977d5-dd4b-43fa-b387-d21859c926f6 Estonia (EE) | 8a37046b-c6e6-444b-9ef7-4198a5945a42 Netherlands (NL) | bf61cd33-8fdf-4e56-9b10-478e625a832f Hungary (HU) | e929be24-8cf5-4186-8523-eac208e44115 Poland (PL) | 6e7d7d7b-24ed-47f8-b329-fe28d8a29247 France (FR) | 45bca760-4e8e-4422-8e17-d79e3701a01f Germany (DE) | 10d103fc-dd56-4250-9221-d52a59d9402d Portugal (PT) | 1d557ba9-7ec6-4ad0-b6c9-5e57aff1bb80 Bulgaria (BG) | 26501976-0da5-4ad4-a77c-262095c9b6a8 Poland (PL) | b5f5c14c-c878-4cd3-8068-f0cf654edbee Sweden (SE) | f7679a0a-463d-4d8c-9e62-ce265f1f4893 France (FR) | 2cdfe6b7-dc30-4101-9331-f7dd999e8937 Belgium (BE) | ef44153e-94c5-4399-9bbe-fc08fe16a72b Spain (ES) | dcb7ec49-fc4d-4976-b03e-6e717d4f2b09 Sweden (SE) | 56ce7b78-a2b9-4f89-b3c8-2697de3737a6 Germany (DE) | c068b237-4d97-423e-9c84-635a7655d2ff Hungary (HU)
Environmental Information
Product Environmental Information Tmax T5 | Breakers - Packaging disposal information
E-Number (Finland)
3655401
EAN
8015644555092
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
186 mm
Product Net Height
205 mm
Product Net Depth / Length
103.5 mm
Product Net Weight
6.2 kg
Package Level 1 Units
1 piece
Package Level 1 Width
248 mm
Package Level 1 Height
240 mm
Package Level 1 Depth / Length
285 mm
Package Level 1 Gross Weight
6.2 kg
Package Level 1 EAN
8015644555092
Product Main Type
SACE Tmax T
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable For
T5
Suitable for Product Class
Moulded Case Circuit Breakers
Version
F
Electrical Durability
5000 cycle | 60 cycles per hour
Mechanical Durability
20000 cycle | 120 cycles per hour
Number of Poles
4P
Power Loss
at Rated Operating Conditions per Pole 41 W
Rated Current (In)
630 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 85 kA | (230 V AC) 85 kA | (380 V AC) 50 kA | (400 V AC) 50 kA | (415 V AC) 50 kA | (440 V AC) 40 kA | (500 V AC) 30 kA | (690 V AC) 25 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 85 kA | (230 V AC) 85 kA | (380 V AC) 50 kA | (400 V AC) 50 kA | (415 V AC) 50 kA | (440 V AC) 40 kA | (500 V AC) 30 kA | (690 V AC) 25 kA
Rated Uninterrupted Current (Iu)
630 A
Release
PR222DS/P-LSIG
Release Type
EL
Short-Circuit Performance Level
S
Standards
IEC
Sub-type
T5
Terminal Connection Type
Fixed Circuit-Breakers | Front
Test Voltage Max (Utest)
3500 V
Test Voltage at Industrial Frequency for 1 Minute
3500 V
Data Sheet, Technical Information
1SDC210004D0203
Declaration of Conformity - CE
EC Declaration of Conformity Tmax T5
GL Certificate
1SDL000163R0062
Instructions and Manuals
Installation instructions Tmax T5
Instructions and Manuals (Part 2)
ITSCE-RH0100001
Instructions and Manuals (Part 3)
Release PR222DS/P and PR222DS/PD T4-T5-T6
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39121100
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature: Four-pole fixed frame with front-terminal connections → Business Impact: Simplifies wiring harness routing and reduces panel assembly time, enabling faster commissioning in control cabinets and switchgear. Application: Ideal for high-current feeders in industrial automation and power distribution. Feature: PR222DS/P-LSIG solid-state release → Business Impact: Delivers precise and reliable tripping performance, minimizing nuisance trips and improving uptime for critical loads. Application: Transformer, generator, and large motor protection schemes in harsh environments. Feature: 630 A rated current and 690 V AC rating (Ui 1000 V) → Business Impact: Provides ample headroom for peak loads while maintaining safety margins, reducing the need for frequent uprates. Application: Utility feeders, MCCs, and high-demand machine lines. Feature: High short-circuit capability (Ics up to 85 kA at low voltages; up to 25–50 kA at higher voltages) → Business Impact: Enhances system resilience against faults, lowering risk of equipment damage and downtime. Application: Panels feeding transformers, large motors, and distribution networks. Feature: Front-accessibility installation and 4P configuration → Business Impact: Speeds installation, simplifies maintenance, and improves serviceability in tight control rooms. Application: Panelboards, switchgear, and compact substations. Feature: Mechanical and electrical durability (20000 mechanical cycles, 5000 electrical cycles) → Business Impact: Extends service life and reduces lifecycle maintenance costs. Application: Continuous operation environments with repetitive switching and fault events. Feature: RoHS, REACH, CMRT, SCIP, TSCA and WEEE compliance → Business Impact: Regulatory-ready qualification for global procurement, minimizing compliance risk and streamlining audits. Application: Global manufacturing sites and eco-conscious deployments. Feature: Packaging and dimensions (186 mm W x 205 mm H x 103.5 mm D; 6.2 kg) → Business Impact: Predictable enclosure fit and weight support for installation planning and shipping. Application: Control cabinets, front-mitted panels, and replacement catalogs.

Get a Quick Quote for a ABB 1SDA054411R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA054411R1? Enquire Now

FAQs

For front-terminal ABB 1SDA054411R1 installation, ensure panel access for front wiring, use appropriate torque on fixed terminals, and mount in a 4P frame with correct clearance. The device is designed for panel boards and switchgear where front access speeds wiring, testing, and replacement while reducing enclosure depth and service time.
Key specs include a rated current of 630 A, rated operational voltage of 690 V AC, rated insulation voltage 1000 V, and a current-limiting impulse withstand of 8 kV. It uses a four-pole frame with PR222DS/P-LSIG release, delivering reliable overload and short-circuit protection across typical industrial feeders.
Yes. The 4P configuration, high Ics/Icu ratings, and 690 V AC operating range support safe feeder protection and generator protection schemes, while the front-terminal design speeds installation in control panels and switchgear. It’s well-suited for dependable transformer and generator protection in demanding environments.
The product complies with IEC standards and carries a CE Declaration of Conformity, RoHS compliance, and REACH declarations. Additional documentation includes CMRT, SCIP listings, TSCA compliance, and WEEE categorization, helping you meet global regulatory and procurement requirements.
Expect improved uptime from 20000 mechanical cycles and 5000 electrical cycles, plus reduced wiring errors thanks to front-terminal access. The result is lower downtime, longer service life, and lower lifecycle costs for critical loads like motors and transformers, aligning with total cost of ownership objectives.