ABB 1SDA054434R1 Moulded Case Circuit Breaker - EC Declaration of Conformity Tmax T5

Part Number: 1SDA054434R1
Manufacturer
ABB
Part number
1SDA054434R1

Quick Summary

ABB 1SDA054434R1 Moulded Case Circuit Breaker provides reliable overcurrent protection for industrial power distribution panels. Engineers often face space constraints and wiring complexity in modern switchgear, and front-terminal 4P designs streamline installation while enhancing reliability. This device carries CE conformity, GL certification, and RoHS/REACH declarations, aligning with widespread global requirements. With a 630 A rating and Tmax T5 compatibility, it supports scalable protection for feeders and transformers, delivering safer, more efficient operation. Procurement teams gain consistency across sites thanks to standardized mechanical and electrical interfaces. Its solid-state release PR222DS/P-LSI adds precision in selective protection schemes.

Product Information

Extended Description

1SDA054434R1 ABB: C.BREAKER TMAX T5V 630 FIXED FOUR-POLE WITH FRONT TERMINALS AND SOLID-STATE RELEASE IN AC PR222DS/P-LSI R 630
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Product Environmental Information Tmax T5 | Breakers - Packaging disposal information
E-Number (Finland)
3655380
EAN
8015644555382
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
186 mm
Product Net Height
205 mm
Product Net Depth / Length
103.5 mm
Product Net Weight
6.2 kg
Package Level 1 Units
1 piece
Package Level 1 Width
248 mm
Package Level 1 Height
240 mm
Package Level 1 Depth / Length
285 mm
Package Level 1 Gross Weight
6.2 kg
Package Level 1 EAN
8015644555382
Product Main Type
SACE Tmax T
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable For
T5
Suitable for Product Class
Moulded Case Circuit Breakers
Version
F
Electrical Durability
5000 cycle | 60 cycles per hour
Mechanical Durability
20000 cycle | 120 cycles per hour
Number of Poles
4P
Power Loss
at Rated Operating Conditions per Pole 41 W
Rated Current (In)
630 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 200 kA | (230 V AC) 200 kA | (380 V AC) 200 kA | (400 V AC) 200 kA | (415 V AC) 200 kA | (440 V AC) 180 kA | (500 V AC) 75 kA | (690 V AC) 40 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 200 kA | (230 V AC) 200 kA | (380 V AC) 200 kA | (400 V AC) 200 kA | (415 V AC) 200 kA | (440 V AC) 180 kA | (500 V AC) 150 kA | (690 V AC) 80 kA
Rated Uninterrupted Current (Iu)
630 A
Release
PR222DS/P-LSI
Release Type
EL
Short-Circuit Performance Level
V
Standards
IEC
Sub-type
T5
Terminal Connection Type
Fixed Circuit-Breakers | Front
Test Voltage Max (Utest)
3500 V
Test Voltage at Industrial Frequency for 1 Minute
3500 V
Data Sheet, Technical Information
1SDC210004D0203
Declaration of Conformity - CE
EC Declaration of Conformity Tmax T5
GL Certificate
1SDL000163R0062
Instructions and Manuals
Installation instructions Tmax T5
Instructions and Manuals (Part 2)
ITSCE-RH0100001
Instructions and Manuals (Part 3)
Release PR222DS/P and PR222DS/PD T4-T5-T6
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39121100
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
High-current capability and robust fault protection translate to fewer nuisance trips and improved line availability, supporting uninterrupted production in heavy-duty environments. Feature → Business Impact → Application: 630 A rated current combined with 200 kA short-circuit capacity at multiple voltages provides a strong safety margin for feeders and transformer circuits, reducing equipment damage and facilitating compliant commissioning in manufacturing plants. The four-pole fixed-front design simplifies wiring and maintenance while saving enclosure space, enabling faster panel upgrades and easier retrofits in existing switchgear. The PR222DS/P-LSI solid-state release delivers precise tripping under overload and short-circuit conditions, improving selectivity and reducing collateral outages in complex distribution networks. Electrical durability of 5000 cycles and mechanical durability of 20000 cycles extend service life in high-switching applications, lowering lifecycle costs. With 690 V AC operation and 8 kV test voltage, the device supports demanding industrial deployments such as data centers and process lines while maintaining insulation margins. Compliance-oriented features including RoHS, REACH, CMRT, TSCA, and EPD documentation simplify supplier audits and procurement risk management, fostering better total cost of ownership. Front-terminal connection and explicit product definitions within the Tmax T5 ecosystem enable straightforward installation, serviceability, and compatibility with ABB equipment to minimize engineering effort and downtime. Industry insight shows that standardized MCCBs like this one reduce spare-part inventories and shorten mean time to repair, translating to measurable uptime gains and predictable maintenance planning.

Get a Quick Quote for a ABB 1SDA054434R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA054434R1? Enquire Now

FAQs

Installation guidance for ABB 1SDA054434R1 focuses on the front-terminal, fixed-mount design. Verify panel clearance, torque settings for terminal screws, and ensure the four-pole alignment fits the busbar configuration. Use the PR222DS/P-LSI release wiring as documented and secure the unit to minimize vibration. This approach reduces commissioning time and improves wiring integrity in dense switchgear assemblies.
Key specifications include a rated current of 630 A, rated operational voltage of 690 V AC, rated insulation voltage of 1000 V, and a rated impulse withstand voltage of 8 kV. It has four poles and a front-terminal connection, with a short-circuit rating up to 200 kA at several voltages. These specs support reliable protection for feeders and transformers in Tmax T5 installations.
Yes. The 1SDA054434R1 is a Moulded Case Circuit Breaker designed for Tmax T5 applications, featuring a PR222DS/P-LSI release for precise protection. Its 630 A rating and front-terminal design facilitate motor feeders in manufacturing and process environments, providing dependable overload and short-circuit protection with easy integration into Tmax T5 ecosystems.
The unit carries CE conformity and GL certification, along with RoHS and REACH declarations. It aligns with IEC standards and provides CMRT and TSCA documentation. Availability of these declarations supports regulatory audits, supplier risk management, and smoother acceptance across diverse global sites.
Investing in the 1SDA054434R1 yields ROI through reduced downtime thanks to robust 630 A protection and high Ics/Icu margins, enhanced maintenance efficiency from front-terminal wiring, and extended component life (5000 electrical and 20000 mechanical cycles). Standardized interfaces simplify procurement and stocking, lowering total cost of ownership for large-scale power-distribution projects.