ABB 1SDA054480R1 Moulded Case Circuit Breaker - 8 kV Uimp

Part Number: 1SDA054480R1
Manufacturer
ABB
Part number
1SDA054480R1

Quick Summary

ABB 1SDA054480R1 Moulded Case Circuit Breaker protects industrial power distribution in machines and substations. Engineers often struggle with nuisance trips, slow fault isolation, and integration challenges in panel builds. This Tmax T5 device adheres to IEC standards with CE conformity and RoHS/REACH declarations, delivering reliable protection and long life. By combining a front-terminal, four-pole design with a thermomagnetic release, it supports fast, safe installation and easy maintenance. The result is improved uptime and predictable protection coordination for retrofit projects and new installations alike.

Product Information

Extended Description

1SDA054480R1 ABB: C.BREAKER TMAX T5S 400 FIXED FOUR-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMA R 400 I3=2000...4000 A FULLY RATED NEUTRAL
Country of Origin
India (IN)
Lead Time
0 day
Made To Order
No
Warranty Return
Product under warranty must be returned
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
AETAD009EXPU
Country of Origin
India (IN)
Lead Time
0 day
Made To Order
No
Warranty Return
Product under warranty must be returned
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
BRABB008EXPU
Country of Origin
India (IN)
Lead Time
0 day
Made To Order
No
Warranty Return
Product under warranty must be returned
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
CHSEC006EXPU
Country of Origin
India (IN)
Made To Order
No
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
INABB003EXPU
Warranty Return
Product under warranty must be returned
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
SCIP
ee487c2c-2f59-49a2-8a39-dc23e14feaa5 Italy (IT)
Simplified SCIP
fc10a7bc-64c2-4804-9409-307796b7694b Germany (DE) | bc9e421a-301b-46c2-9d58-f5b4fe8e753e Germany (DE) | 563faea8-adfa-425e-ae01-0bbd3a83076e Croatia (HR) | 8a0132d4-5364-4233-bbc6-5f9241753da5 Denmark (DK) | eb966244-beee-4028-99ff-2a14f7edfe1f Germany (DE) | d8324714-5299-470f-9aa5-817c33873c50 Spain (ES) | 12184db9-bcf3-4ab2-9851-f4a24aee98f5 Hungary (HU) | 61585d0e-6fd7-456d-9566-924ab951e914 France (FR) | 739677d1-666f-4a78-933c-e09d1ff0e943 Belgium (BE) | 09bb96db-32e3-4250-9bbf-137d21e6a017 Bulgaria (BG) | 9728f118-79b6-40f4-a0a7-b6c5bd6b7a08 Poland (PL) | a8d2464b-887c-45b1-8daa-c2e13508c48a Estonia (EE) | a4a26625-db93-4c49-b9cb-7312df8a6e97 Portugal (PT) | f53a9b65-39fc-4a9f-9a97-81adae63b362 Poland (PL) | 780192de-6838-4fda-9b48-87cd87ba1a6f Germany (DE) | bbfa3c86-995d-4841-9649-b3e86c327bd0 Sweden (SE) | 4302899e-43e9-4267-8abd-8117cecc310a Czech Republic (CZ) | 2a73c98e-176e-46a8-8ae0-82980d045e99 Germany (DE) | ac7e96a9-876e-4502-972e-bbeec165e830 Sweden (SE) | d25cb4c7-5325-4450-96df-84085285be76 Netherlands (NL) | fdb056a8-7505-4378-b1bd-b5919866b51e Norway (NO) | 173ea64b-7d86-481c-9031-c560a46281e8 Finland (FI) | 422cd193-f794-473e-aab2-84d451a37726 Hungary (HU) | 037e412d-75a3-4b79-88cd-3afcccfe5940 Poland (PL) | ad4ee288-3bc1-4d79-9c8e-59c82e4f694c Belgium (BE) | 4b9749fa-6428-4f71-88fe-6502592242ff France (FR) | 8970f40d-8292-48eb-84c0-ac41b44a9262 Greece (GR)
Environmental Information
Product Environmental Information Tmax T5 | Breakers - Packaging disposal information
EAN
8015644555177
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
186 mm
Product Net Height
205 mm
Product Net Depth / Length
103.5 mm
Product Net Weight
5.8 kg
Package Level 1 Units
1 piece
Package Level 1 Width
248 mm
Package Level 1 Height
240 mm
Package Level 1 Depth / Length
285 mm
Package Level 1 Gross Weight
5.8 kg
Package Level 1 EAN
8015644555177
Product Main Type
SACE Tmax T
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable For
T5
Suitable for Product Class
Moulded Case Circuit Breakers
Version
F
Electrical Durability
7000 cycle | 60 cycles per hour
Mechanical Durability
20000 cycle | 120 cycles per hour
Number of Poles
4P
Power Loss
at Rated Operating Conditions per Pole 19.5 W
Rated Current (In)
400 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC | 750 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 85 kA | (230 V AC) 85 kA | (380 V AC) 50 kA | (400 V AC) 50 kA | (415 V AC) 50 kA | (440 V AC) 40 kA | (500 V AC) 30 kA | (690 V AC) 25 kA
Rated Short-time Withstand Current Low Voltage (Icw)
for 1 s 5 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 85 kA | (230 V AC) 85 kA | (380 V AC) 50 kA | (400 V AC) 50 kA | (415 V AC) 50 kA | (440 V AC) 40 kA | (500 V AC) 30 kA | (690 V AC) 25 kA | (250 V DC) 2 Poles in Series 50 kA | (500 V DC) 2 Poles in Series 36 kA | (750 V DC) 3 Poles in Series 25 kA
Rated Uninterrupted Current (Iu)
400 A
Release
TMA
Release Type
TM
Short-Circuit Performance Level
S
Standards
IEC
Sub-type
T5
Terminal Connection Type
Fixed Circuit-Breakers | Front
Test Voltage Max (Utest)
3500 V
Data Sheet, Technical Information
1SDC210004D0203
Declaration of Conformity - CE
EC Declaration of Conformity Tmax T5
GL Certificate
1SDL000163R0062
Instructions and Manuals
Installation instructions Tmax T5
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39121100
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
The fixed four-pole front-terminal design with the TMA release provides robust protection while simplifying wiring and panel assembly, reducing commissioning time and wiring errors in switchgear. In practical terms, this translates to lower installation costs and faster fault isolation, especially in compact control panels and transformer feeder units. With a rated current of 400 A and a rated operating voltage of 690 V AC / 750 V DC, it supports demanding loads common in power distribution for industrial equipment, motors, and transformers while maintaining safe disconnects. The device offers high short-circuit capability, with Ics up to 85 kA at various voltages and Icw of 5 kA for 1 s, enabling dependable protection coordination for critical lines and feeders. Uimp is 8 kV, ensuring reliable performance against transient surges and lightning impulses. Power loss stands at 19.5 W per pole under rated conditions, contributing to cooler operation and reduced cooling infrastructure needs. Mechanical durability reaches 20000 cycles and electrical durability 7000 cycles, supporting long service life in production environments. RoHS and REACH declarations, CMRT, and SCIP data reinforce regulatory compliance across multiple regions, while stock-keeping at international warehouses supports 0 day lead times for urgent projects.

Get a Quick Quote for a ABB 1SDA054480R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA054480R1? Enquire Now

FAQs

Installation requires mounting the four-pole MCCB in a suitable panel, connecting wiring to the front terminals, and securing with the correct torque per the datasheet. Use the TMA release for proper tripping coordination, verify that the neutral is fully rated, and ensure busbar and feeder connections reflect the protection zones. Adhering to IEC installation guidelines minimizes operational risk and speeds commissioning.
Key specs include In 400 A, Ui 1000 V, Uimp 8 kV, Ue 690 V AC / 750 V DC, Ics up to 85 kA, Icw 5 kA for 1 s, and Iu 400 A. It features 4P front-terminal connection, a TMA release, and a power loss of 19.5 W per pole. These values support robust transformer and motor protection with reliable short-circuit response.
Yes. Tmax T5 MCCBs from the SACE Tmax family are designed for transformer and generator protection, offering high Ics/Icu ratings, a fully rated neutral, and front-terminal access for streamlined wiring. Its 8 kV impulse withstand and IEC compliance make it a strong choice for substations, switchgear, and panel boards requiring reliable fault isolation.
The device carries a CE declaration of conformity and IEC standards compliance. It is RoHS compliant, REACH declared, and documented under CMRT for conflict minerals. GL certification is also listed, reflecting broad regulatory alignment for global industrial deployment and supply-chain transparency.
With 7000 cycles in electrical endurance and 20000 mechanical cycles, the MCCB promises long life with minimal maintenance. Energy losses are limited to 19.5 W per pole, reducing cooling needs. Stocked at multiple warehouses with 0 day lead time, it supports rapid deployment, reducing downtime and accelerating project ROI in new builds or retrofits.