ABB 1SDA054487R1 Moulded Case Circuit Breaker - 8 kV

Part Number: 1SDA054487R1
Manufacturer
ABB
Part number
1SDA054487R1

Quick Summary

ABB 1SDA054487R1 is a moulded case circuit breaker for protecting power distribution in industrial electrical systems. Engineers and procurement teams often face downtime risk from nuisance trips, wiring errors, and difficult retrofits; this device addresses those pain points with front-terminals and a robust four-pole design. It carries CE conformity, IEC standards alignment, and RoHS compliance to simplify regulatory approvals while supporting CMRT/SCIP tracking. By aligning with Tmax T5 family specs and ABB EcoSolutions support, it delivers installation efficiency, predictable performance, and long-term reliability across critical lines, transformers, and motor feeders.

Product Information

Extended Description

1SDA054487R1 ABB: C.BREAKER TMAX T5N 630 FIXED FOUR-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMA R 500 I3=2500...5000 A FULLY RATED NEUTRAL
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
SCIP
8ea6d253-7613-40a7-a6fa-fbd709b583a7 Italy (IT)
Simplified SCIP
8dbd99d8-d911-4ab4-a7ff-057f0945bd9a Portugal (PT) | a5b76277-631e-4846-a38a-d3d66f265dcf Czech Republic (CZ) | 74880610-2272-4554-a060-e61620781baf France (FR) | da7308d2-2ab8-40dc-8821-311865d01f00 Hungary (HU) | 8a19a1b5-c850-4c66-9a55-13c3036c4c7f Spain (ES) | 3d086f4d-cdea-48a1-b85f-3188a5c9e45a Belgium (BE) | 6a26213f-ee35-49eb-ace4-81d1a66dbc7c Germany (DE) | c673bce7-c58d-4251-830a-a9f96a8a3297 Germany (DE) | 42e7a7d6-8174-405d-8499-54c3979b1eb1 Croatia (HR) | f00718c8-cbac-4c96-9839-21732bd7fba8 Germany (DE) | 60c653db-7707-425f-baec-588216ff7e58 Denmark (DK) | ef855491-6b74-4b75-a03d-1e16c62b480a Sweden (SE) | 4d9d2f57-267e-44a9-bc5b-8de3c051e639 Germany (DE) | a8ae8355-8b4d-41bc-b284-e1fe5ef4f73b France (FR) | 0f1c0312-323b-4182-b06a-e4e850f65a58 Greece (GR) | 14978e3f-1fb7-485a-b8dd-87fcf9f54014 Belgium (BE) | ac04c386-2e9f-4e14-9864-954d966da675 Estonia (EE) | 7a2a9efb-1f6f-4405-94cb-e4572411e0db Finland (FI) | 50a608eb-2cea-47bf-ba8c-71cb57bb957c Hungary (HU) | 54c02cff-cefe-4bc1-b46b-34d48c60ea9e Poland (PL) | 1b909852-07aa-4e99-8a77-c11f9d3c9b41 Poland (PL) | 05a3d635-2087-4bb7-bb3c-f6cca52f3548 Norway (NO) | a2bba8ac-8399-4319-8676-f93a96858c25 Sweden (SE) | acc50e10-323f-4f99-8737-294113b2d41b Netherlands (NL) | b19029a5-7124-4a68-8c4d-db7802b4de24 Poland (PL) | b873828e-d27b-4bf5-9389-586ed8646b2d Bulgaria (BG) | 59e62547-3a98-47e1-8985-f9e621c2459f Germany (DE)
Environmental Information
Product Environmental Information Tmax T5 | Breakers - Packaging disposal information
EAN
8015644555849
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
186 mm
Product Net Height
205 mm
Product Net Depth / Length
103.5 mm
Product Net Weight
5.8 kg
Package Level 1 Units
1 piece
Package Level 1 Width
248 mm
Package Level 1 Height
240 mm
Package Level 1 Depth / Length
285 mm
Package Level 1 Gross Weight
5.8 kg
Package Level 1 EAN
8015644555849
Product Main Type
SACE Tmax T
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable For
T5
Suitable for Product Class
Moulded Case Circuit Breakers
Version
F
Electrical Durability
5000 cycle | 60 cycles per hour
Mechanical Durability
20000 cycle | 120 cycles per hour
Number of Poles
4P
Power Loss
at Rated Operating Conditions per Pole 28.8 W
Rated Current (In)
500 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC | 750 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 70 kA | (230 V AC) 70 kA | (380 V AC) 36 kA | (400 V AC) 36 kA | (415 V AC) 36 kA | (440 V AC) 30 kA | (500 V AC) 25 kA | (690 V AC) 20 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 70 kA | (230 V AC) 70 kA | (380 V AC) 36 kA | (400 V AC) 36 kA | (415 V AC) 36 kA | (440 V AC) 30 kA | (500 V AC) 25 kA | (690 V AC) 20 kA | (250 V DC) 2 Poles in Series 36 kA | (500 V DC) 2 Poles in Series 25 kA | (750 V DC) 3 Poles in Series 16 kA
Rated Uninterrupted Current (Iu)
630 A
Release
TMA
Release Type
TM
Short-Circuit Performance Level
N
Standards
IEC
Sub-type
T5
Terminal Connection Type
Fixed Circuit-Breakers | Front
Test Voltage Max (Utest)
3500 V
Test Voltage at Industrial Frequency for 1 Minute
3500 V
Data Sheet, Technical Information
1SDC210004D0203
Declaration of Conformity - CE
EC Declaration of Conformity Tmax T5
Instructions and Manuals
Installation instructions Tmax T5
Instructions and Manuals (Part 2)
ITSCE-RH0100001
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39121100
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature → Business Impact → Application: Four-pole Tmax T5N with front terminals and a TM release enables straightforward wiring in compact panels, reducing installation time and wiring errors in new builds and retrofits. This translates to lower labor costs and faster commissioning for distribution boards in manufacturing plants. Feature → High current rating of 500 A and Iu = 630 A improves continuous protection against overloads, minimizing unplanned downtime in conveyor systems and machine controls. Feature → Uimp = 8 kV and Ui = 1000 V provide robust insulation and surge resistance, ensuring safe operation in harsh factory environments and with motor drives. Feature → Short-circuit capability up to 70 kA at standard voltages delivers reliable fault clearing, enhancing system resilience in energy-intensive applications. Feature → Front-terminal, 4P configuration and 690 V AC / 750 V DC ratings support easy integration with modern switchgear and high-energy panels. Feature → Mechanical and electrical durability (20,000 cycles / 5,000 cycles) supports long service life in continuous production lines, reducing replacement intervals and lifecycle costs.

Get a Quick Quote for a ABB 1SDA054487R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA054487R1? Enquire Now

FAQs

The 4P front-terminal configuration simplifies wiring by allowing straight busbar connections into a compact enclosure. Confirm a 186 mm wide, 205 mm high footprint and 103.5 mm depth, then secure the device in the panel frame. Use torque values recommended in the installation instructions and connect to 690 V AC or 750 V DC circuits with the 500 A nominal rating to ensure reliable protection and easy future upgrades.
Key specs include In = 500 A, Iu = 630 A, Ui = 1000 V, Uimp = 8 kV, and a rated operational voltage of 690 V AC / 750 V DC. The device provides up to 70 kA Ics at standard voltages and 70 kA ICU in appropriate configurations, making it suitable for motor feeders and transformer protection in medium-energy panels.
Yes. The 1SDA054487R1 is part of the Tmax T5 family, featuring a TMA release suitable for motor and transformer protection. With front terminals, four poles, and a 500 A rating, it supports reliable switching and quick integration in motor drive circuits and panelboards while meeting IEC and CE expectations.
Absolutely. ABB Sace circuit breakers, including this model, carry RoHS declarations and REACH compliance. SCIP registration is provided as part of ABB’s sustainability data, along with CMRT reporting. This helps ensure regulatory alignment for European and global supply chains and supports responsible sourcing and end-of-life disposal.
The unit offers high mechanical durability (up to 20,000 cycles) and electrical durability (up to 5,000 cycles), reducing maintenance intervals and the risk of nuisance trips. This translates into lower downtime, fewer panel rewiring events, and improved system availability for production lines and critical power distribution networks.