ABB 1SDA054581R1 Moulded Case Circuit Breaker - Tmax T5

Part Number: 1SDA054581R1
Manufacturer
ABB
Part number
1SDA054581R1

Quick Summary

ABB 1SDA054581R1 Moulded Case Circuit Breaker protects electrical distribution systems in industrial switchgear. Manufacturers face downtime and wiring challenges when selecting protective devices that fit tight spaces and front-terminals. This model meets CE conformity, IEC standards, and RoHS/REACH requirements, with TSCA and CMRT declarations to support global sourcing. Its Tmax T5 compatibility and front-terminal design simplify installation, reduce wiring errors, and lower total cost of ownership across control panels. In practice, maintenance teams appreciate the compact footprint and reliable 3P protection under demanding Tmax T5 operating conditions. Together with robust safety standards, the device supports fast compliance checks during audits.

Product Information

Extended Description

1SDA054581R1 ABB: BREAKING PART TMAX T5V 400 FIXED THREE-POLE WITH FRONT TERMINALS
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Product Environmental Information Tmax T5 | Breakers - Packaging disposal information
EAN
8015644556792
Minimum Order Quantity
1 piece
Customs Tariff Number
85389099
Product Net Width
140 mm
Product Net Height
205 mm
Product Net Depth / Length
103.5 mm
Product Net Weight
3.25 kg
Package Level 1 Units
1 piece
Package Level 1 Width
248 mm
Package Level 1 Height
240 mm
Package Level 1 Depth / Length
285 mm
Package Level 1 Gross Weight
3.8 kg
Package Level 1 EAN
8015644556792
Product Main Type
SACE Tmax T
Product Name
Moulded Case Circuit Breaker
Product Type
Breaking Part
Suitable For
T5
Suitable for Product Class
Moulded Case Circuit Breakers
Version
F
Device
Breaking Part
Electrical Durability
7000 cycle | 60 cycles per hour
Mechanical Durability
20000 cycle | 120 cycles per hour
Number of Poles
3P
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC | 750 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 200 kA | (230 V AC) 200 kA | (380 V AC) 200 kA | (400 V AC) 200 kA | (415 V AC) 200 kA | (440 V AC) 180 kA | (500 V AC) 150 kA | (690 V AC) 80 kA
Rated Short-time Withstand Current Low Voltage (Icw)
for 1 s 5 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 200 kA | (230 V AC) 200 kA | (380 V AC) 200 kA | (400 V AC) 200 kA | (415 V AC) 200 kA | (440 V AC) 180 kA | (500 V AC) 150 kA | (690 V AC) 80 kA | (250 V DC) 2 Poles in Series 150 kA | (500 V DC) 2 Poles in Series 100 kA | (750 V DC) 3 Poles in Series 70 kA
Rated Uninterrupted Current (Iu)
400 A
Short-Circuit Performance Level
V
Standards
IEC
Sub-type
T5
Terminal Connection Type
Fixed Circuit-Breakers | Front
Test Voltage Max (Utest)
3500 V
Test Voltage at Industrial Frequency for 1 Minute
3500 V
Data Sheet, Technical Information
1SDC210004D0203
Declaration of Conformity - CE
EC Declaration of Conformity Tmax T5
GL Certificate
1SDL000163R0062
Instructions and Manuals
Installation instructions Tmax T5
Instructions and Manuals (Part 2)
ITSCE-RH0100001
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature: Front-terminal fixed circuit-breaker design enables quick, secure wiring in tight panel spaces. Business impact: reduces wiring time, minimizes connection faults, and enhances operator safety during maintenance. Application: ideal for compact control panels in packaging lines and machine rooms. Long-tail keywords: front-terminal MCCB, 3P front-terminal breaker, panel wiring efficiency. Feature: Rated for 690 V AC or 750 V DC with 400 A nominal current. Business impact: supports robust power distribution to motors and feeders while maintaining high availability. Application: motor protection and distribution boards in industrial settings. Long-tail keywords: 690 V MCCB, 400 A protection, motor feeder protection. Feature: High breaking capacity Ics up to 200 kA and Icu up to 200 kA across multiple voltages. Business impact: superior short-circuit protection reduces downstream damage and downtime. Application: critical power circuits in process lines and transformer feeds. Long-tail keywords: high breaking capacity, 200 kA, short-circuit protection. Feature: Durability specs with electrical 7000 cycles and mechanical 20000 cycles. Business impact: extended service life lowers maintenance costs and replacement frequency. Application: high-cycle protection in continuous-operation facilities. Long-tail keywords: electrical durability, mechanical durability, lifecycle. Feature: Comprehensive compliance and documentation including CE, REACH, RoHS, CMRT, TSCA, and EPD notes. Business impact: simplifies global procurement, audit readiness, and sustainability reporting. Application: multinational projects and regulated industries. Long-tail keywords: RoHS compliance, REACH declaration, TSCA, CMRT, environmental information. Feature: Dimensional and packaging data (width 140 mm, height 205 mm, depth 103.5 mm; weight 3.25 kg; 1 piece packaging). Business impact: predictable enclosure planning, easier logistics, and accurate BOMs. Application: panel design and procurement planning for SACE Tmax T5 devices. Long-tail keywords: MCCB dimensions, panel fit, packaging unit. This combination of features supports reliable protection, faster installs, and lower total cost of ownership in modern industrial environments.

Get a Quick Quote for a ABB 1SDA054581R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA054581R1? Enquire Now

FAQs

Install the 3P front-terminal MCCB in an appropriate enclosure, align with the panel’s mounting provisions, and connect each phase to the front terminals. Ensure the enclosure accommodates a 140 mm width and 205 mm height footprint. Tighten connections to the manufacturer’s torque specifications, verify rated voltage compatibility (690 VAC/750 V DC), and confirm clearances for safe operation and maintenance access.
The device provides a short-circuit breaking capacity up to 200 kA (Ics) across multiple voltages and an ultimate breaking capacity up to 200 kA in several configurations. It also offers a rated service short-circuit current (Ics) and rated ultimate short-circuit current (Icu) with 1 s withstand (Icw 5 kA). Electrical durability is rated at 7000 cycles, mechanical durability at 20000 cycles.
Yes. It is a 3P fixed, front-terminal breaker designed for Tmax T5, with a rated operational voltage of 690 VAC and RoHS/REACH compliance, CE declaration, and IEC standards. Its electrical performance supports motor protection and distribution tasks in European control panels, offering reliable protection for motor starters and feeders while fitting standard Tmax T5 configurations.
This breaker ships with CE Declaration of Conformity, GL certification, RoHS compliance, REACH declaration, and CMRT for conflict minerals reporting. It also references TSCA compliance and product environmental information. Documentation supports audit readiness, international procurement, and regulatory compliance for global manufacturing and installation projects.
The device delivers electrical durability of 7000 cycles and mechanical durability of 20000 cycles, reducing maintenance and replacement frequency in high-cycle applications. Its compact 140x205 mm footprint and front-terminal design simplify installation and service, lowering labor costs, downtime, and spare-part consumption while ensuring consistent protection performance in harsh industrial environments.