ABB 1SDA054663R1 Accessory - 4P Thermomagnetic Release

Part Number: 1SDA054663R1
Manufacturer
ABB
Part number
1SDA054663R1

Quick Summary

ABB 1SDA054663R1 is a four-pole thermomagnetic release accessory for Tmax T circuit breakers. Maintenance teams often struggle with reliable trip coordination and field configurability during faults. This accessory carries IEC standards and CE conformity, with RoHS and REACH declarations supporting regulatory and environmental compliance. Together with easy integration for Tmax T products, it reduces downtime, simplifies installation, and helps meet demanding industrial safety requirements. In practice, the TMA release ensures precise tripping under overload, protecting downstream equipment and personnel. Its loose or configurable configuration type supports flexible field setup. Engineers appreciate the 4-pole design for reliable phase protection and straightforward compatibility with SACE Tmax T families.

Product Information

Extended Description

1SDA054663R1 ABB: THERMOMAGNETIC RELEASE FOUR-POLE IN AC-DC TMA R 80 I3=400...800 A T4
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
Document availability on demand
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
EAN
8015644557683
Minimum Order Quantity
1 piece
Customs Tariff Number
85389099
Product Net Weight
1 kg
Package Level 1 Units
1 piece
Package Level 1 Width
158 mm
Package Level 1 Height
158 mm
Package Level 1 Depth / Length
188 mm
Package Level 1 Gross Weight
1.1 kg
Package Level 1 EAN
8015644557683
Product Main Type
Accessories for Tmax T
Product Name
Accessory
Product Type
Accessory
Suitable For
T4
Suitable for Product Class
SACE Tmax T
Configuration Type
Loose or configurable
Number of Poles
4P
Rated Current (In)
80 A
Release
TMA
Release Type
Thermomagnetic trip unit
Standards
IEC
Data Sheet, Technical Information
1SDC210015D0201
Declaration of Conformity - CE
1SDL000165R0001
Instructions and Manuals
1SDC210015D0201
ETIM 8
EC001023 - Shunt release (for power circuit breaker)
Object Classification Code
Q
UNSPSC
39121100
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370418
The four-pole thermomagnetic release (TMA) inside 1SDA054663R1 delivers precise overcurrent protection for Tmax T systems. Rated at 80 A (I_n), this device maintains fast response during short circuits while suppressing nuisance trips. Business impact: sharper protection coordination reduces motor and feeder damage, shortening downtime and extending equipment life. Application: ideal for SACE Tmax T installations in manufacturing lines and critical distribution panels requiring reliable four-pole protection. Compliance and declarations underpin risk management and procurement confidence. The unit supports RoHS information, REACH declarations, and CE conformity, with TSCA considerations documented and available. Documentation includes a CE Declaration of Conformity (1SDL000165R0001) and data sheet (1SDC210015D0201), helping engineering teams qualify, test, and maintain the device with minimal rework. CMRT availability on demand further enhances supply-chain transparency and sustainability reporting, which is valuable for regulated industries and global sourcing programs. Configuration and installation are streamlined by loose or configurable mounting options and full Tmax T compatibility. The 4P 80 A accessory integrates into standard panel architectures, reducing spare-parts variety and accelerating commissioning. With easy wiring, field configuration, and documented setup, engineers can shorten project timelines and achieve repeatable protection schemes across multiple panels. Reliability and uptime are improved through a robust thermomagnetic trip unit that delivers consistent coordination during overload and short-circuit conditions. The compact footprint (1 kg net, 1.1 kg gross) and packaging (158 x 158 x 188 mm) simplify inventory and installation, while the EC classification and ETIM alignment support accurate parts data in maintenance systems.

Get a Quick Quote for a ABB 1SDA054663R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA054663R1? Enquire Now

FAQs

Install the four-pole TMA release as a loose or configurable accessory in the Tmax T assembly. Verify compatibility with the Tmax T family, then wire per the data sheet 1SDC210015D0201. Ensure the unit is seated correctly, test the trip function under controlled conditions, and reference the CE declaration (1SDL000165R0001) for conformity requirements. The installation supports straightforward field configuration, minimizing commissioning time and risk.
Key specs include four poles (4P), rated current 80 A (I_n), release type Thermomagnetic (TMA), and suitability for T4 fault conditions within SACE Tmax T systems. The device adheres to IEC standards and is CE compliant, with RoHS and REACH declarations. These specifications support reliable protection, panel interoperability, and regulatory compliance across industrial environments.
Yes. The accessory is designed as a 4P thermomagnetic release for Tmax T systems and is suitable for T4 protection schemes. Its 80 A rating and four-pole configuration provide robust overload protection and precise tripping, ensuring safe and reliable operation in demanding industrial applications.
The product includes IEC standards alignment and CE conformity, with RoHS and REACH declarations. Documentation also covers TSCA, and a CE Declaration of Conformity (1SDL000165R0001) plus the data sheet (1SDC210015D0201). CMRT documents are available on demand to support supply-chain transparency and sustainability reporting.
Using the 1SDA054663R1 improves uptime through reliable protection coordination, reducing equipment damage and downtime. Its field-configurable design lowers commissioning time and spare-part complexity, while documented compliance eases audits and global procurement. Over time, these factors translate to lower maintenance costs, quicker changeouts, and a more predictable lifecycle for Tmax T protection architectures.